1. Intended Use

2. Technical Information

VL-FLD Series Large Area Flat Dome Light is designed for use in industrial
areas. Purpose of the product is inspection of parts, positioning, color check, code reading, 
quality inspection, robot picking. Light is positioned above the part.

The system must be operated within the limits specified in technical data and used according 
to technical specifications as well as installation instructions. The system must be used in 
such a way that no person are in danger or machines and other material goods are 
damaged in the event of malfunction or total failure of the system. Take additional  precautions 
for safety and damage prevention in case of safety related applications.

P2

Ver. 20.3.001

VL-FLD-300-300-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

300 

300 

352 

385 

26

VL-FLD-400-400-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

400 

400 

452 

485 

26

VL-FLD-500-500-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

500 

500 

552 

585 

26

VL-FLD-600-600-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

600 

600 

652 

685 

26

VL-FLD-700-700-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

700 

700 

752 

785 

26

VL-FLD-800-800-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

800 

800 

852 

885 

26

VL-FLD-900-900-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

900 

900 

952 

985 

26

VL-FLD-1000-1000-W-24-C30 

6500K 

24VDC 

M8 4 pin w 300mm cable 

1000 

1000 

1052 

1085 

26

24W
34W
43W
50W
70W
80W
90W
100W

Model

Wavelength/

Color

Temperature

Power

Suppy

Power Consumption

Connection

A(mm)

B(mm)

C(mm)

D(mm)

E(mm)

Colour

Содержание VL-FLD Series

Страница 1: ...Instruction Manual Product VL FLD Series Large Area Flat Dome Light FÖGE ELEKTRONIK GMBH Böhleswasenweg 11 72555 Metzingen www fogegmbh com info fogegmbh com 49 7123 9570508 P1 Ver 20 3 001 ...

Страница 2: ...e prevention in case of safety related applications P2 Ver 20 3 001 VL FLD 300 300 W 24 C30 W 6500K 24VDC M8 4 pin w 300mm cable 300 300 352 385 26 VL FLD 400 400 W 24 C30 W 6500K 24VDC M8 4 pin w 300mm cable 400 400 452 485 26 VL FLD 500 500 W 24 C30 W 6500K 24VDC M8 4 pin w 300mm cable 500 500 552 585 26 VL FLD 600 600 W 24 C30 W 6500K 24VDC M8 4 pin w 300mm cable 600 600 652 685 26 VL FLD 700 7...

Страница 3: ...y is shown in section 8 Safety of manual P3 Ver 20 3 001 Camera VL FLD Part Sample Applications Wide area contamination detection Color differentiation classification on big objects Wide area position detection surface inspection Accessories VL FLD Series VL BLA BR 01 1 Suitable Product Ordering Code Accessories Image ...

Страница 4: ...de only with strobe input with given ON OFF percentage Due to high illumination settings use this mode only with strobe input with given ON OFF percentage Due to high illumination settings use this mode only with strobe input with given ON OFF percentage Due to high illumination settings use this mode only with strobe input with given ON OFF percentage ON 100 OFF 0 Standard High Intensity ON 85 OF...

Страница 5: ...gs Connect the power supply and the display output device according to the safety regulations for electrical equipment The supply voltage must not exceed the specified limits Avoid shocks and impacts to the sensor Protect the cable against damage Possible Results of Avoidance Risk of injury by electric shock Damage to or destruction of the sensor P5 Ver 20 3 001 ...

Страница 6: ...y for material defects Repairs are carried out exclusively by FÖGE Further claims can not be made Claims arising from the purchase contract remain unaffected In particular FÖGE shall not be liable for any consequential special indirect or incidental damage In the interest of further development FÖGE reserves the right to make design changes without notification 10 Decommissioning Disposal Remove t...

Отзывы: