Start by pressing the ACQ
key. The fogcannon will rotate clockwise until point 0. Once the cannon
stops at Point 0, press and hold the Left Arrow
key until the desired RIGHT stopping point is reached.
Press the ACQ
key to set first set point. Press and hold the Left Arrow
key until the desired LEFT
stopping point is reached. Press the ACQ
key to set the second set point. The ACQ value shown on the
control panel display will show 0 meaning that the desired angle has been set up correctly and that the
machine is ready to operate in the AUTO mode.
After setting the rotation angle, the machine will oscillate automatically when the System (SYS) is set to the
AUTO mode.
OPERATE THE SYSTEM IN MANUAL MODE (manual oscillation)
Use the
key to toggle between the 3 pages.
Check the settings on Page 1. SYS should be MAN and all EV should be set to 0;
Check the settings on Page 2. PMP should be AUTO and RADIO should be OFF
Check the settings on Page 3. TIM should be OFF
Press the FAN
key to turn the Fan and Pump ON
Press the Electric Valve
,
, and/or
keys (or rotate the manual zone valves if the unit is not
equipped with Electric Valves) to open the appropriate zone(s) on the crown.
The cannon can be rotated by pressing the LEFT
and RIGHT
arrows. The cannon can be
raised/lowered by pressing the UP
and DOWN
arrows (or raised and lowered manually if the unit is
not equipped with Electric Tilt).
To terminate the operation, press the
FAN key once and press the appropriate Electric Valve
,
,
and/or
keys once (or rotate the manual zone valves if the unit is not equipped with Electric Valves).
OPERATE THE SYSTEM IN AUTO MODE (auto oscillation)
The Rotation Angle must be set before operating the system in the AUTO mode.
Use the
PAGE key to toggle between the 3 pages.
Check the settings on Page 1. SYS should be in MAN; and all EV should be set to 0;
Check the settings on Page 2. PMP should be in AUTO and RADIO should be OFF
Check the settings on Page 3. TIM should be OFF.
Press the Electric Valve
,
, and/or
keys (or rotate the manual zone valves if the unit is not
equipped with Electric Valves) to open the appropriate zone(s) on the crown.
Press the
SISTEM key to change the system from MAN to AUTO.
The buzzer will sound for 3 seconds and the cannon will rotate to the 0 position. The cannon will then rotate
to the 1 position. The fan will turn ON. The cannon will continue to rotate to the 2 position. The Pump will
turn ON.
The system will continue to oscillate between position 1 and position 2 until the SISTEM key is pressed
again.
Once the SISTEM
key is pressed again, the oscillation, the Fan, the Pump will turn OFF immediately.
All valve (Electric and Manual) must be turned Off separately.
NOTES:
When the system is in AUTO, only the following keys on the display key pad will operate:
The UP and DOWN arrows for raising and lowering the cannon (if equipped with Electric Tilt)
The Electric Valve (EV) keys (if equipped with Electric Zone Valves)