ALARMS
The page EMERGENCY STOP indicates that the emergency stop button, which is placed on the side
of the control panel, has been pushed manually or that a malfunctioning occurred causing the safety
relay to stop the machine. The red Tower Light starts flashing.
SOLUTION: Verify the origin of the malfunction and if necessary, contact Fogco Technical Assistance.
Only after that the malfunction is solved, pull the emergency stop button and reset the internal breaker
as described below.
The alarm WRONG ROTATION – INVERT PHASE indicates that one of the electrical phases is
inverted. In this case, the angle cannot be set up in automatic mode.
SOLUTION: Contact a qualified electrician to invert the phases.
The alarm appears when the automatic mode had been selected and the angle had not been set up.
SOLUTION: Follow the SET THE ROTATION ANGLE instructions above.
This alarm indicates that the pump is not supplied with enough water. The pump stops and the red
and yellow Tower Lights mounted on the frame start flashing for three minutes.
SOLUTION: The machine starts working again automatically if the pump receives the correct water
quantity again within three minutes. The machine stops automatically if the water flow is not restored
within three minutes. Verify the origin of the malfunction. Press the F1 to reset key only after solving
the malfunction.
This alarm appears when a problem at one of the motors arises. The corresponding safety switch
blows.
SOLUTION: Check the origin of the malfunction and contact a qualified electrician. If the malfunction
can be attributed to a loss of current, restore the machine by turning the motor start selector switch in
position 1. If the malfunctioning persists, contact the authorized Technical Assistance Service.