background image

ALARMS 

 

  

The page EMERGENCY STOP indicates that the emergency stop button, which is placed on the side 
of the control panel, has been pushed manually or that a malfunctioning occurred causing the safety 
relay to stop the machine. The red Tower Light starts flashing. 

 

SOLUTION: Verify the origin of the malfunction and if necessary, contact Fogco Technical Assistance. 
Only after that the malfunction is solved, pull the emergency stop button and reset the internal breaker 
as described below.   

 

 

  

The  alarm  WRONG  ROTATION  –  INVERT  PHASE  indicates  that  one  of  the  electrical  phases  is 
inverted. In this case, the angle cannot be set up in automatic mode. 

 

SOLUTION: Contact a qualified electrician to invert the phases.  

 

  

The alarm appears when the automatic mode had been selected and the angle had not been set up. 

 

SOLUTION: Follow the SET THE ROTATION ANGLE instructions above.   

 

  

This alarm indicates that the pump is not supplied with enough water. The pump stops and the red 
and yellow Tower Lights mounted on the frame start flashing for three minutes. 

 

SOLUTION: The machine starts working again automatically if the pump receives the correct water 
quantity again within three minutes. The machine stops automatically if the water flow is not restored 
within three minutes. Verify the origin of the malfunction. Press the F1 to reset key only after solving 
the malfunction. 

 

  

This  alarm  appears  when  a  problem at  one  of  the  motors  arises.  The  corresponding  safety switch 
blows. 

 

SOLUTION: Check the origin of the malfunction and contact a qualified electrician.  If the malfunction 
can be attributed to a loss of current, restore the machine by turning the motor start selector switch in 
position 1. If the malfunctioning persists, contact the authorized Technical Assistance Service. 

 
 

Содержание FogCannon HD 160

Страница 1: ...co FogCannon HD 160 HD 230 HD 300 Pole Trailer FOGCO Environmental Solutions 600 S 56th Street Chandler AZ 85226 Phone 800 607 6478 Fax 480 838 2232 Website www fogco com e mail info fogco com Rev0808...

Страница 2: ...or 1st level operator without specific skill able to perform only simple tasks such as the operation of the machine using the buttons on the Machine panel or Remote operations of loading and unloading...

Страница 3: ...shroom or part to use Machine in movement with automatic function mobile protection guards closed with relevant blocking device activated and fixed protector guards closed Machine in movement mobile p...

Страница 4: ...Name Dangerous electrical tension Crushing of upper limbs Getting caught Dragging Access forbidden to unauthorized persons Do not remove safety devices Prohibited to clean oil grease repair or adjust...

Страница 5: ...the manufacturer shall void the warranty and the manufacturer shall not be held liable for damage caused by the faulty product ARRANGEMENTS TO BE PROVIDED BY CUSTOMER The following are the sole respon...

Страница 6: ...manually or in Remote mode serve to adjust the rotation angle and to make the fogcannon work within the selected angles set up at the user s own discretion Filter The unit is fitted with a 100 mesh f...

Страница 7: ...E 3 TIM TIMER WORK PAUSE Shows if the timer is On ON or Off OFF TIM ON WORKING TIME The first column shows the working time in minutes from 5 to 30 minutes If the timer is On the second column shows t...

Страница 8: ...on by loosening the cannon Tilt Handle located on the tilt assembly next to the main control panel raise or lower the cannon as needed tighten the Tilt Handle Manually open close the valves for the in...

Страница 9: ...pped with Electric Tilt To terminate the operation press the FAN key once and press the appropriate Electric Valve and or keys once or rotate the manual zone valves if the unit is not equipped with El...

Страница 10: ...tely and run until the PMP is set to OFF NOTE The Electric Valves will NOT be automatically activated whenever the pump is running They must be turned on seperately by pressing the appropriate EV key...

Страница 11: ...he crown can be operated seperately or simultaneously creating a wide range of flow options for the unit The table below provides approximate flow given the standard nozzles and the number of zones be...

Страница 12: ...had not been set up SOLUTION Follow the SET THE ROTATION ANGLE instructions above This alarm indicates that the pump is not supplied with enough water The pump stops and the red and yellow Tower Light...

Страница 13: ...CUIT BREAKER When the machine is stopped with the emergency stop it requires to switch on the circuit breaker with the following procedure Restore the emergency stop Dismount the front protection usin...

Страница 14: ...Remove the front protection and switch off the main switch white arrow Open the electric cabinet and look for the blue colored circuit breaker orange arrow...

Страница 15: ...Lift up the switch as shown in picture blue arrow Close the electric cabinet and the front protection Switch on the main switch white arrow...

Страница 16: ...dity ranging from 30 to 95 The machine may not be used in environments with A corrosive atmosphere A risk of fire An explosive atmosphere A risk of stones being ejected Water and chemical substances t...

Страница 17: ...ce operations must be performed by qualified and authorized staff It is mandatory to wear the necessary personal protection devices It is mandatory to respect and observe all alarms and warnings In th...

Страница 18: ...s to the manufacturer The Machine must be taken out of service until operating anomalies are verified and corrected or repaired Certify that there are no objects between the Machine parts Check that n...

Страница 19: ...NGEROUS ZONES Dangerous zones include but are not limited to electrical substation or areas where there are electrical parts with IP level lower than IP 55 and or areas where there is the risk of expl...

Страница 20: ...socket Disassemble the nozzles using a 5 8 socket wrench and a 5 32 Allen wrench Brush slots on the top of the nozzle inserts with a stainless steel wire brush to remove all debris Remove the O ring...

Страница 21: ...Maintenance executed Date Done by Notes...

Страница 22: ...Maintenance executed Date Done by Notes...

Страница 23: ...An explanation of the defect or problem a description of the way in which the FogCannon is used the customers name address and telephone number the FogCannon model number and the serial number must b...

Страница 24: ...______________________________ FogCannon serial number on metal tag ______________________________________ Manufacture date on metal tag _____________________________________________ Are you intereste...