SYSTEM AUTO mode is initiated by pressing and holding the SYSTEM AUTO button for 3 seconds.
SYSTEM AUTO mode is terminated by pressing the SYSTEM AUTO button again.
Turn OFF the RADIO mode by pressing the RADIO button on the control panel keypad.
Turn OFF the Radio Transmitter by pushing the red tab on the top of the Transmitter inward.
OPERATING FLOW OPTIONS
The individual zones on the crown can be operated seperately or simultaneously creating a wide range of
flow options for the unit. The table below provides approximate flow given the standard nozzles and the
number of zones being used.
GPM Flow Using Various Zones
HD 160 HD230 HD 300
Zone 1
6
4.2
4.2
Zone 2
9
8.3
8.3
Zone 3
N/A
12.5
12.5
Zone 1/2
15
12.5
12.5
Zone 1/3
N/A
16.7
16.7
Zone 2/3
N/A
20.8
20.8
Zone 1/2/3
N/A
25
25
HD 160: Dual Zone with 36-10 GPH and 36-15 GPH nozzles
HD230: Triple Zone with 50 - 5 GPH, 50-10 GPH; and 50-15 GPH nozzles
HD300: Triple Zone with 50 - 5 GPH, 50-10 GPH; and 50-15 GPH nozzles