Faults and warnings
39
NOTICE!
An interruption in feeding operation means that your calves will not receive any feed.
This can lead to malnutrition. Malnutrition can cause impaired growth and development, in-
creased susceptibility to illness or even the death of your calves.
►
You must use an alternative method to supply your calves with feed as long as the automatic
feeder is out of service.
You can correct the fault as follows:
1. Acknowledge a
Fault Hoses circuit clean
message by pressing
.
2. Check all hoses to determine if they are blocked, kinked or frozen up.
3. Choose
> Diagnostics > Stations
in the
Feed
sub-menu.
4. Select
the desired feeding box and press
HygieneBox
.
5. Confirm
Valve set
and choose
back
. Confirm with
.
6. In
water to drain
or
water to mixer
shows the check (
) behind the selected line the last
position to which the valve was switched.
7. Press
water bo.: open?
until
the mixer is filled with water.
8. Confirm
pumping water
to pump the water in the circuit or into the gully. The direction
can be detected at
.
9. Replace the hoses if necessary.
10. Respond to
Delete fault?
by pressing
, once you have rectified the fault.
10.1.3 Flushing circuit leaking.
You will see the text
Fault rinsing circuit leak
in the display if when cleaning all the pipework
a leakage point or a leaky valve is detected.
NOTICE!
An interruption in feeding operation means that your calves will not receive any feed.
This can lead to malnutrition. Malnutrition can cause impaired growth and development, in-
creased susceptibility to illness or even the death of your calves.
►
You must use an alternative method to supply your calves with feed as long as the automatic
feeder is out of service.
You can correct the fault as follows:
1. Acknowledge a
Fault rinsing circuit leak
message by pressing
.
2. Choose
> Diagnostics > Stations
in the
Feeds
sub-menu.