Maintenance/servicing
7.2.1
Daily
Visual inspection of the components
•
The teats, the suction hose and the return hose must be checked on a daily basis for dam-
age, leaks and wear. If any damage or wear is detected during the visual inspection, the
faulty components must be replaced by a service technician before operation of the Hy-
gieneBox is resumed.
•
The plastic housing must be checked on a daily basis for damage and wear. If any damage
or wear is detected during the visual inspection, the faulty components must be replaced be-
fore operation of the HygieneBox is resumed.
•
The 3/2-way valve must be checked on a daily basis for leaks and damage. If any damage
or wear is detected during the visual inspection, the valve must be replaced before operation
of the HygieneBox is resumed.
•
The discharge tray and the stops incorporated in it must be checked on a daily basis for
damage and wear. If any damage or wear is detected during the visual inspection, the faulty
components must be replaced before operation of the HygieneBox is resumed.
•
The hoses of the teat cleaning system must be checked on a daily basis for damage, leaks
and wear. If any damage or wear is detected during the visual inspection, the teat cleaning
system must be deactivated before the faulty components are replaced by a service techni-
cian.
7.2.2
Every 3 months
All the teats must be replaced every 3 months. This reduces the risk of infection.
7.2.3
Annually
Every 12 months the suction hose and the return hose must be replaced by a service technician.