Before commencing Installation, confirm that the details on the appliance 

data plate correspond to the local distribution conditions, gas type and 

pressure to which the appliance is to be installed.

Ensure that gas supply and supply pipe is capable of delivering the 

required volume and pressure of gas and is in accordance with the rules 

in force.

 GAS CONNECTION

 VENTILATION

This appliance is a Balanced Flue room sealed appliance, and as such 

needs no additional ventilation. However an adequate supply of fresh air to 

maintain temperatures and a comfortable environment is recommended.

This appliance may be installed in a completely sealed or mechanically 

ventilated house.

 APPLIANCE INSTALLATION

Determine the position required for the appliance.

Create a gas connection for the appliance in approximately the correct 

location for the gas controls.

The gas controls are connected to the Burner of the appliance.

This appliance must be securely fixed to the floor using the fixings built 

into the base of the appliance.

Do not make any adjustments to the appliance.

The appliance and Flue system should be fitted with a minimum clearance 

of 500mm from any combustible objects or materials; this includes any 

combustible materials used for the fireplace construction.

As this is a room sealed appliance and the appliance stands appropriately 

and is securely fixed to the floor, a hearth is not required for this appliance.

A gap of 100mm should be left all round the appliance.

 FLUE CONNECTION

A. GENERAL NOTES

This appliance may be installed with a roof terminal (C31) or a wall terminal 

(C11).

This appliance may only be used with Balanced Flue (otherwise known 

as Concentric Flue) parts as specified by Focus. The Focus specified flue 

parts have been approved with the appliance. If the appliance is installed 

on non-Focus approved parts, Focus cannot guarantee or accept and 

responsibility for the proper and safe working of the appliance.

The flue system must be constructed from the appliance upwards, with all 

joints being fully locked and sealed using the Focus specified parts.

B. TIMBER FRAME CONSTRUCTION

Whilst it is possible to install room-sealed appliances in timber frame 

properties, great care needs to be taken to ensure that the flue assembly 

does not interfere with the weather proofing qualities of any outer wall 

which it may penetrate. Before attempting this work, further details need 

to be referenced, (e.g. “Gas Installations in Timber Frame Buildings” from 

the CORGI installer series in the UK).

C. CARPORT OR BUILDING EXTENSION

Where a flue terminal is sited within a carport or building extension, it 

should have at least two completely open and unobstructed sides. The 

distance between the lowest part of the roof and the top of the terminal 

should be at least 600mm.

Note: A covered passageway should not be treated as a carport. Flues 

should not be sited in a covered passageway between properties.

D. BASEMENTS, LIGHTWELLS AND RETAINING WALLS

Flue terminals should not be sited within the confines of a basement area, 

light well or external space formed by a retaining wall, unless steps are 

taken to ensure the products of combustion can disperse safely at all 

times. It may be possible to install this Balanced Flue system in such a 

location provided that it is not sited lower than 1m from the top level of that 

area to allow combustion products to disperse safely.

Flue terminals should be sited to ensure total clearance of the combustion 

products in accordance with the included information.

When the products of combustion are discharged, they should not cause a 

nuisance to adjoining or adjacent properties and they should be positioned 

so that damage cannot occur to other parts of the building. If the outer wall 

surface is constructed of combustible material, a non-combustible plate 

should be fitted behind the terminal projecting 25mm beyond the external 

edges of the terminal.

Installation instructions

Содержание Curvifocus

Страница 1: ...CURVIFOCUS _____ INSTALLATION SERVICING AND USER INSTRUCTIONS...

Страница 2: ...surfaces and as such should not be touched The front windows and surrounds are not considered to be fully secure guards against accidental contact It is recommended that an approved fire screen be use...

Страница 3: ...e limits Ambient battery temperature range 32 F to 131 F 0 C to 55 C New and old batteries and different brands of batteries should not be used together Mixing of various batteries can cause the batte...

Страница 4: ...buttons simultaneously Minutes flash 6 To select minutes press or button 7 To confirm press and buttons simultaneously or wait E CHILD PROOF ON To activate press and buttons simultaneously displayed a...

Страница 5: ...button ignition operation by pressing and holding button for 10 sec immediately after installing batteries ON is displayed and 2 is flashing When change is complete 2 will change to 1 NOTICE If the p...

Страница 6: ...om temperature is lower than the set temperature the flame height stays on high for a longer period of time If the room temperature is higher than the set temperature the flame height stays on low for...

Страница 7: ...tinue to PROGRAM 2 and set on and off times or stop programming at this point and PROGRAM 2 remains deactivated NOTE PROGRAM 1 and 2 use the same on Thermostatic and off temperatures for and Daily Tim...

Страница 8: ...ppliance at the rear CLEANING AND MAINTENANCE This appliance should be inspected and serviced once a year by a qualified competent and registered person The inspection and maintenance must at least en...

Страница 9: ...cept and responsibility for the proper and safe working of the appliance The flue system must be constructed from the appliance upwards with all joints being fully locked and sealed using the Focus sp...

Страница 10: ...0 H From an internal or external corner 600 I Above ground roof or balcony level 300 J From a surface facing the terminal 600 K From a terminal facing the terminal 600 L From an opening in the car por...

Страница 11: ...65mm V H 0 4 opening R fully open G VERTICAL ROOF VENT TERMINATION C31 Flue sizing 100 150 Connector on Appliance for Poujoulat PGI concentric flue system 100 150 Adaptor for Metaloterm Ontop or Mueli...

Страница 12: ...n arranging the Media into the Firebed it is imporant that the Pilot area is kept clear and that no Media enters the Pilot shield The Pilot area includes the pilot shield and the top of the burner to...

Страница 13: ...LAY Scatter the Bags of Embers over the top of the burners as shown keeping the piot area clear Position Logs C1 C2 C3 as shown in the diagram Position Log C4 as shown in the diagram Installation inst...

Страница 14: ...and burner pressure 1 Turn off the gas valve on the appliance 2 Release the screw on the Inlet Pressure test point on the gas valve and connect a manometer 3 Check that the measured pressure is as th...

Страница 15: ...sites When using a vacuum cleaner it is recommended that one with a HEPA filtering system is used Re fit the Firebed arrangement re seal the appliance and check the safe operation of the appliance SER...

Страница 16: ...I2H G20 at 20 mbar I3 G31 G31 at 28 37 mbar I3P 37 G31 at 37 mbar I3B P 30 G30 G31 at 30 mbar HU Hungary I3B P 30 G30 G31 at 30 mbar HR Croatia I2H G20 at 20 mbar I3P 37 G31 at 37 mbar I3B P 30 G30 G...

Страница 17: ...0 892 Burner Pressure hot mbar 14 2 14 2 17 8 14 2 17 8 Injector Marking 650 Pilot 446 1385 44 Efficiency Class 2 Nox Class 5 Curvifocus LPG Gas type G30 G31 G31 I3B P 30 50 I3 I3P 37 50 I3P 30 Supply...

Страница 18: ...18 DIMENSIONS 360 521 919 1800 150 280 1203 1000 A 100 150 219 DETAIL A CURVIFOCUS Technical Information...

Страница 19: ...n new code reset See label on receiver Transmitter distance limited 1 Straighten the antenna 2 Replace receiver See wiring diagram p 23 2 Magnet unit is energized audible thud to detect functionality...

Страница 20: ...d all metal parts Shorten IGN cable if possible or cover e g silicon hose See wiring diagram p 23 No IGN sequence stops no pilot flame No reaction to transmitter command Controller crashes Press RESET...

Страница 21: ...pilot stays lit No Resistance in thermo current circuit too high Check cable in thermo current circuit See wiring diagram p 23 Magnet unit drops audible sound Not enough heat on thermocouple Check pos...

Страница 22: ...gement of thermo couple Check installation OK 9 Magnet unit drops while motor turns 3 beeps No Low batteries Replace receiver batteries with 1 5V AA quality alkaline batteries System can be switched O...

Страница 23: ...23 WIRING DIAGRAM Appendix...

Страница 24: ...described here are in accordance with the appliances described in the EC Type Examination Certificate No UK LHD 0359 0657R1 delivered by INTERTEK and comply with the essential requirements applicable...

Страница 25: ...25 Note...

Страница 26: ...26 Note...

Страница 27: ...27 Note...

Страница 28: ...tion dition Distribution Atelier dominique imbert S A S au capital de 102 355 euros 34380 Viols le Fort France Tel 00 33 0 4 67 55 01 93 Fax 00 33 0 4 67 55 77 77 Web www focus creation com Email info...

Отзывы: