03

 EMERGENCY GAS ISOLATION

In the event of a gas leak or if gas is smelt, the appliance must be isolated. 

This is done by turning OFF the gas at the Isolation Tap. This Isolation Tap 

is located in the foot of the appliance, at the rear.

 FIRST TIME OF OPERATION

Before igniting the appliance, ensure that all packaging, safety stickers 

and any protective wrapping have been removed, and that the glass has 

been cleaned, including all fingerprints from the glass.

Ensure that the room is adequately ventilated the first time that the 

appliance is ignited; we would recommend opening windows if possible. 

Run the appliance at full setting for a few hours so that the paint gets an 

opportunity to fully cure. During this period it is possible for some fumes 

and vapours to be given off. We would recommend keeping children and 
pets out of the area at this time.

 OPERATING INSTRUCTIONS

A. GENERAL NOTES

Wiring of valve and receiver must be completed before starting ignition. 

Failure to do so could damage the electronics.

NOTICE

Batteries – Handset

· 

Low battery indicator on handsets.

Batteries – Receiver

· 

Low battery indication: frequent beeps for 3 seconds when motor turns.

· 

An AC mains adapter may be used instead of batteries.

· 

The module for fan speed control and light/dimmer includes mains  

power together with batteries in the receiver for automatic backup in  

case of power outage.

· 

Without using a mains adapter, battery replacement is recommended  

at the beginning of each heating season.

· 

Old or dead batteries should be removed immediately. If left in the unit  

the batteries can overheat, leak, and / or explode.

· 

Do NOT expose batteries (including during storage) to direct 

sunlight, excessive heat, fire, moisture, or severe impact. Each of these 

conditions can cause the batteries to overheat, leak, and / or explode.

· 

Batteries must be kept within their recommended temperature limits.  

(Ambient battery temperature range: 32 °F to 131 °F [0 °C to 55 °C].) 

· 

New and old batteries and different brands of batteries should not be  

used together. Mixing of various batteries can cause the batteries 

to overheat, leak, and / or explode.

 WARNING

Software Version

Press   and   buttons simultaneously. Software version is displayed.

Handset Model Number

Press   and   buttons simultaneously. Handset model number 

is displayed.

Deactivate Functions

1. Install batteries. All icons are displayed and flashing.

2. While the icons are flashing, press the relevant function button and hold  

for 10 sec.

3. The function icon will flash until deactivation is complete. Deactivation  

is complete when the function icon and two horizontal bars are displayed. 

NOTE: If a deactivated button is pressed, there is no function, and two  

   

horizontal bars are displayed.

NOTE: Deactivation remains in effect after change of batteries.

Activate Functions

1. Install batteries. All icons are displayed and flashing.

2. To activate a function, press the relevant button and hold for 10 sec.

3. The function icon will continue to flash until activation is complete.  

Activation is complete when the function icon is displayed.

The following Functions can be Deactivated / Activated

· 

CHILD PROOF

· 

PROGRAM MODE

· 

THERMOSTATIC MODE (also deactivates PROGRAM MODE)

· 

ECO MODE

· 

LIGHT / DIMMER OPERATION

· 

CIRCULATING FAN OPERATION

· 

AUXILIARY FEATURE

· 

COUNTDOWN TIMER

B. SETTING THE ELECTRONIC CODE (First time use only)

Radio Frequency Handset

A code is selected automatically for all Mertik Maxitrol electronics from 

among 65,000 codes available. The receiver must be paired with the 

handset.

The receiver has to learn the handset code:

Press and hold the receiver’s reset button until you hear two (2) beeps. After 

the second, longer beep, release the reset button. Within the subsequent 

20 seconds press the   button on the handset until you hear two (2) short 

beeps confirming the code is set.

NOTE: This is a one time setting only, and it is not required when changing  

   

the batteries In the handset or receiver.

User instructions

Содержание Curvifocus

Страница 1: ...CURVIFOCUS _____ INSTALLATION SERVICING AND USER INSTRUCTIONS...

Страница 2: ...surfaces and as such should not be touched The front windows and surrounds are not considered to be fully secure guards against accidental contact It is recommended that an approved fire screen be use...

Страница 3: ...e limits Ambient battery temperature range 32 F to 131 F 0 C to 55 C New and old batteries and different brands of batteries should not be used together Mixing of various batteries can cause the batte...

Страница 4: ...buttons simultaneously Minutes flash 6 To select minutes press or button 7 To confirm press and buttons simultaneously or wait E CHILD PROOF ON To activate press and buttons simultaneously displayed a...

Страница 5: ...button ignition operation by pressing and holding button for 10 sec immediately after installing batteries ON is displayed and 2 is flashing When change is complete 2 will change to 1 NOTICE If the p...

Страница 6: ...om temperature is lower than the set temperature the flame height stays on high for a longer period of time If the room temperature is higher than the set temperature the flame height stays on low for...

Страница 7: ...tinue to PROGRAM 2 and set on and off times or stop programming at this point and PROGRAM 2 remains deactivated NOTE PROGRAM 1 and 2 use the same on Thermostatic and off temperatures for and Daily Tim...

Страница 8: ...ppliance at the rear CLEANING AND MAINTENANCE This appliance should be inspected and serviced once a year by a qualified competent and registered person The inspection and maintenance must at least en...

Страница 9: ...cept and responsibility for the proper and safe working of the appliance The flue system must be constructed from the appliance upwards with all joints being fully locked and sealed using the Focus sp...

Страница 10: ...0 H From an internal or external corner 600 I Above ground roof or balcony level 300 J From a surface facing the terminal 600 K From a terminal facing the terminal 600 L From an opening in the car por...

Страница 11: ...65mm V H 0 4 opening R fully open G VERTICAL ROOF VENT TERMINATION C31 Flue sizing 100 150 Connector on Appliance for Poujoulat PGI concentric flue system 100 150 Adaptor for Metaloterm Ontop or Mueli...

Страница 12: ...n arranging the Media into the Firebed it is imporant that the Pilot area is kept clear and that no Media enters the Pilot shield The Pilot area includes the pilot shield and the top of the burner to...

Страница 13: ...LAY Scatter the Bags of Embers over the top of the burners as shown keeping the piot area clear Position Logs C1 C2 C3 as shown in the diagram Position Log C4 as shown in the diagram Installation inst...

Страница 14: ...and burner pressure 1 Turn off the gas valve on the appliance 2 Release the screw on the Inlet Pressure test point on the gas valve and connect a manometer 3 Check that the measured pressure is as th...

Страница 15: ...sites When using a vacuum cleaner it is recommended that one with a HEPA filtering system is used Re fit the Firebed arrangement re seal the appliance and check the safe operation of the appliance SER...

Страница 16: ...I2H G20 at 20 mbar I3 G31 G31 at 28 37 mbar I3P 37 G31 at 37 mbar I3B P 30 G30 G31 at 30 mbar HU Hungary I3B P 30 G30 G31 at 30 mbar HR Croatia I2H G20 at 20 mbar I3P 37 G31 at 37 mbar I3B P 30 G30 G...

Страница 17: ...0 892 Burner Pressure hot mbar 14 2 14 2 17 8 14 2 17 8 Injector Marking 650 Pilot 446 1385 44 Efficiency Class 2 Nox Class 5 Curvifocus LPG Gas type G30 G31 G31 I3B P 30 50 I3 I3P 37 50 I3P 30 Supply...

Страница 18: ...18 DIMENSIONS 360 521 919 1800 150 280 1203 1000 A 100 150 219 DETAIL A CURVIFOCUS Technical Information...

Страница 19: ...n new code reset See label on receiver Transmitter distance limited 1 Straighten the antenna 2 Replace receiver See wiring diagram p 23 2 Magnet unit is energized audible thud to detect functionality...

Страница 20: ...d all metal parts Shorten IGN cable if possible or cover e g silicon hose See wiring diagram p 23 No IGN sequence stops no pilot flame No reaction to transmitter command Controller crashes Press RESET...

Страница 21: ...pilot stays lit No Resistance in thermo current circuit too high Check cable in thermo current circuit See wiring diagram p 23 Magnet unit drops audible sound Not enough heat on thermocouple Check pos...

Страница 22: ...gement of thermo couple Check installation OK 9 Magnet unit drops while motor turns 3 beeps No Low batteries Replace receiver batteries with 1 5V AA quality alkaline batteries System can be switched O...

Страница 23: ...23 WIRING DIAGRAM Appendix...

Страница 24: ...described here are in accordance with the appliances described in the EC Type Examination Certificate No UK LHD 0359 0657R1 delivered by INTERTEK and comply with the essential requirements applicable...

Страница 25: ...25 Note...

Страница 26: ...26 Note...

Страница 27: ...27 Note...

Страница 28: ...tion dition Distribution Atelier dominique imbert S A S au capital de 102 355 euros 34380 Viols le Fort France Tel 00 33 0 4 67 55 01 93 Fax 00 33 0 4 67 55 77 77 Web www focus creation com Email info...

Отзывы: