19
MERTIK FAULT FINDING CHART
FUNCTION
POSSIBLE CAUSE
REMEDY
1
HANDSET START:
Press both buttons
to start ignition (IGN)
sequence. Beep will
occur each second.
No
Transmitter batteries low.
Replace transmitter batteries.
9V quality alkaline recommended.
Receiver batteries low.
Replace receiver batteries with 1.5V “AA” quality
alkaline batteries.
Optional mains adapter not operating properl
y.
Check mains adapter.
OK
Check coding of transmitter and receiver. (Initial sync.)
Learn new code (reset).
See label on receiver.
Transmitter distance limited.
1. Straighten the antenna.
2. Replace receiver.
See wiring diagram, p. 23.
2
Magnet unit is
energized (audible
thud to detect
functionality).
No
No beep
Impulse magnet not
operating properly.
Replace gas valve.
No
3 short
beeps
Low batteries.
Replace receiver batteries with 1.5V “AA” quality
alkaline batteries.
No
1 long
beep
ON/OFF switch
in OFF position.
Switch to ON.
OK
8-wire cable Off/not
operating properly.
Check 8-wire cable.
SW-cable disconnected.
Check cable connection.
See figure 1 on page 23.
Motor not operating
properly.
Replace gas valve.
Micro switch not
operating properly.
Replace gas valve.
Appendix
Содержание Curvifocus
Страница 1: ...CURVIFOCUS _____ INSTALLATION SERVICING AND USER INSTRUCTIONS...
Страница 18: ...18 DIMENSIONS 360 521 919 1800 150 280 1203 1000 A 100 150 219 DETAIL A CURVIFOCUS Technical Information...
Страница 23: ...23 WIRING DIAGRAM Appendix...
Страница 25: ...25 Note...
Страница 26: ...26 Note...
Страница 27: ...27 Note...