5.0 OPERATING THE APPLIANCE
6.0 COMBUSTION MONITORING SYSTEM
7.0 CLEANING
GB IE
The control knob is located on the lower right hand side of the outer case. It is marked
as shown in figure 5.
• All models : The pilot is visible behind the left hand side of the burner.Push in and
turn the control knob to the SPARK position, and hold there for a few seconds.
• Continue turning anti-clockwise through the double spark click to the PILOT light
position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat.
• When the pilot lights after the spark, keep the knob pressed for approximately ten
seconds. Now release the knob and the pilot should stay alight.
• If the pilot is extinguished during use, wait three minutes before repeating the igni-
tion procedure.
• To achieve the HIGH setting, push the control knob in slightly and turn fully anti-clockwise to the high posi-
tion. The main burner should light after a few seconds.
• To decrease the setting to low, turn the control knob clockwise to the LOW setting.
• To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release.
• To turn the fire off, keep the knob pressed in, return to the OFF position and release.
This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts down during use for no apparent reason then sev-
eral reasons may be suspected. If a door or window has been opened creating a draught, then pilot disturbance could be the problem and
removal of the draught should resolve this. The appliance can then be re-lit in accordance with the previous section. If pilot disturbance is not
the cause, then the ODS safety system may be in operation. Switch the appliance OFF, call in your installer to check the appliance and ventila-
tion. Remedial work must be carried out as required. DO NOT allow the appliance to be used until the appliance and installation is passed as
safe. If the pilot continues to be extinguished, you must call your installer to check the operation of the complete appliance.
Before carrying out any of the following operations, ensure that the appliance is OFF and completely cold. Regularly clean around the appliance
to ensure that dust, fluff, pet hair etc, are kept to a minimum. There are no other specific requirements for care, other than regular cleaning of
the general appliance. A wipe with a dry cloth is normally sufficient. DO NOT use abrasive cleaners as they can damage the finish. Metal parts
may be cleaned using an appropriate metal cleaner. Test on a hidden part before cleaning. Clean only in the direction of the grain.
GLASS PANEL - This can be cleaned with a suitable glass cleaner. Test on a small area first.
PAINTED AREAS - These can be cleaned using a dry cloth.
‘OFF’ position
‘SPARK’ position
‘LOW’ position
‘HIGH’ position
Figure 5
FIN:
A
Figure 4
8.0 SERVICING
9.0 LIST OF REPLACEMENT PARTS
The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot.
The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried out by
a GAS SAFE registered person. The Installation instructions carry full servicing details for the use of the installer.
PART NO.
ITEM
F960001
Inner glass door assembly (P23 models)
F550339
Inner glass door assembly (L23 models)
F730092
Restrictor - Natural gas
F730095
Restrictor - LPG
F730023
Pilot assembly - Natural Gas (SIT 9082)
F730023
Pilot assembly - Natural Gas (Copreci 21100)
F730075
Pilot assembly - LPG
F730086
Gas valve
TRAY110
Burner unit - Natural gas (P23 models)
TRAY109
Burner unit - Natural gas (L23 models)
TRAY119
Burner unit - LPG (P23 models)
TRAY118
Burner unit - LPG (L23 models)
F780079
Catalyst (seal kit must also be supplied)
F940136
Seal kit for Catalyst
10.0 INSTALLATION DETAILS
Installer GAS SAFE registration No :
Model :
Fire serial No. :
Name & contact details of installer :
Supplied by :
Date installed :