5.0 OPERATING THE APPLIANCE

6.0 COMBUSTION MONITORING SYSTEM

7.0 CLEANING

GB IE

The control knob is located on the lower right hand side of the outer case. It is marked

as shown in figure 5.

•  All models : The pilot is visible behind the left hand side of the burner.Push in and

turn the control knob to the SPARK position, and hold there for a few seconds. 

• Continue turning anti-clockwise through the double spark click to the PILOT light

position, ensuring the pilot has lit. If not, return the knob clockwise, and repeat. 

• When the pilot lights after the spark, keep the knob pressed for approximately ten

seconds. Now release the knob and the pilot should stay alight. 

• If the pilot is extinguished during use, wait three minutes before repeating the igni-

tion procedure.  

• To achieve the HIGH setting, push the control knob in slightly and turn fully anti-clockwise to the high posi-

tion. The main burner should light after a few seconds. 

• To decrease the setting to low, turn the control knob clockwise to the LOW setting.

• To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. 

• To turn the fire off, keep the knob pressed in, return to the OFF position and release.

This fire is fitted with a combustion monitoring safety device (ODS).  If the appliance shuts down during use for no apparent reason then sev-

eral reasons may be suspected.  If a door or window has been opened creating a draught, then pilot disturbance could be the problem and

removal of the draught should resolve this.  The appliance can then be re-lit in accordance with the previous section. If pilot disturbance is not

the cause, then the ODS safety system may be in operation.  Switch the appliance OFF, call in your installer to check the appliance and ventila-

tion.  Remedial work must be carried out as required.  DO NOT allow the appliance to be used until the appliance and installation is passed as

safe. If the pilot continues to be extinguished, you must call your installer to check the operation of the complete appliance. 

Before carrying out any of the following operations, ensure that the appliance is OFF and completely cold. Regularly clean around the appliance

to ensure that dust, fluff, pet hair etc, are kept to a minimum. There are no other specific requirements for care, other than regular cleaning of

the general appliance. A wipe with a dry cloth is normally sufficient. DO NOT use abrasive cleaners as they can damage the finish. Metal parts

may be cleaned using an appropriate metal cleaner. Test on a hidden part before cleaning. Clean only in the direction of the grain. 

GLASS PANEL -  This can be cleaned with a suitable glass cleaner.  Test on a small area first.

PAINTED AREAS - These can be cleaned using a dry cloth.

‘OFF’ position

‘SPARK’ position

‘LOW’ position

‘HIGH’ position

Figure 5

 

    FIN:

A

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

Figure 4

8.0 SERVICING

9.0 LIST OF REPLACEMENT PARTS

The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot.

The frequency of service will depend on usage, but MUST be carried out at least once annually.  Servicing must be carried out by

a GAS SAFE registered person. The Installation instructions carry full servicing details for the use of the installer.

PART NO.

ITEM

F960001

Inner glass door assembly (P23 models)

F550339

Inner glass door assembly (L23 models)

F730092

Restrictor - Natural gas

F730095

Restrictor - LPG

F730023

Pilot assembly - Natural Gas (SIT 9082)

F730023

Pilot assembly - Natural Gas (Copreci 21100)

F730075

Pilot assembly - LPG

F730086

Gas valve

TRAY110

Burner unit - Natural gas (P23 models)

TRAY109

Burner unit - Natural gas (L23 models)

TRAY119

Burner unit - LPG (P23 models)

TRAY118

Burner unit - LPG (L23 models)

F780079

Catalyst (seal kit must also be supplied)

F940136

Seal kit for Catalyst

10.0 INSTALLATION DETAILS

Installer GAS SAFE registration No : 

Model :

Fire serial No. :

Name & contact details of installer :

Supplied by :

Date installed :

Содержание L23 CHESHIRE

Страница 1: ...ages and layout of this booklet is owned by Focal Point Fires plc You are not permitted to copy or adapt any of the con tent without the prior written permission of Focal Point Fires plc Revision F 03...

Страница 2: ...should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the ro...

Страница 3: ...ection and installation of such device shall be in accor dance with the current edition of BSEN 50292 and the user must be briefed regarding the use and maintenance of such a device The appliance is d...

Страница 4: ...any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 0 The appliance must not be positioned vertically within 100 mm 4 of a...

Страница 5: ...eaf of a conven tional cavity brick wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings...

Страница 6: ...e knob depressed in the nine o clock position for approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three min utes before rep...

Страница 7: ...e glass facia panel is supported by four M6 screws which protrude from the front of the outer casing Ensure each screw is unscrewed approximately one turn from the fully screwed in posi tion in order...

Страница 8: ...head Check the aeration holes are free from lint or dirt The pilot assembly can be removed if required by disconnecting the electrode HT lead gas pipe and unscrewing the mounting screws and lifting aw...

Страница 9: ...O concentration as displayed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide co...

Страница 10: ...there is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thorou...

Страница 11: ...cess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed such as installation...

Страница 12: ...ntly fixed in position or can be moveable and can incorporate open fires including combination grates or closed fires including room heaters and stoves See figures 2 3 for fireguard examples The fireg...

Страница 13: ...low the appliance to be used until the appliance and installation is passed as safe If the pilot continues to be extinguished you must call your installer to check the operation of the complete applia...

Страница 14: ...ems such as any ceramics including coals pebbles the matrix front strips side cheeks rear panels and tapered rear panels are not covered by the 3 year guarantee For all Electric fires purchased the 3...

Отзывы: