INSTALLATION INSTRUCTIONS
Preliminary Notes Before Installation
This appliance is a high efficiency, flueless, flame effect gas fire. It provides radiant and con-
vected warmth both efficiently and safely utilising the latest type catalytic convertor burner
technology.
The appliance incorporates a combustion monitoring system (Oxygen Depletion System). It
must not be adjusted or put out of operation. If replaced then manufacturers original parts
must be used.
The appliance is designed to fit various types of situations as listed in the Installation
Requirements.
This appliance must be installed in accordance with the rules in force and only used in a suf-
ficiently ventilated space. A minimum of 100cm
2
(15.5in
2
) purpose provided ventilation is
required for this appliance. An openable window or louvre is also required. This appliance is
factory set for operation on the gas type, and at the pressure stated on the appliance data
plate.
The room size should be a minimum of 23m
3
(812ft
3
) to allow adequate circulation of air
and ensure the correct operation of the fire. This volume may include adjacent spaces but
these spaces must not be separated by a door. In order to convert from cubic feet (ft
3
) to
cubic metres (m
3
) divide the room volume (in ft
3
) by 35.3. This appliance is intended as a
secondary source of heat only and should not be used in a room without some form of
background heating present.
The appliance must not be installed in a bedroom, bathroom or any sleeping area. The
appliance does not require a flue system of any type as the catalytic converter cleans the
flue products to provide a complete combustion system, which is intrinsically safe.
The appliance must be installed by a competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998 or rules in force. It is strongly recommended that a
CORGI registered engineer is used for this purpose, as they are the only persons approved
by the HSE under the above regulations.
On initial lightup of a new appliance, the ‘newness’ will burn off within the first few hours of
operation. During this period some smoke may be emitted from outlet grille, this should be
no cause for concern. Accordingly, the room should be well ventilated with all windows
and doors open during this period.
Read all these instructions before commencing installation.