background image

FITTING THE DECORATIVE FRAME ASSEMBLY

P23 Monet Trio models :
The appliance is supplied with a selection of
differently couloured decorative frames.
Remove the chosen decorative frame assem-
bly  from any protective packaging, and
remove any protective film that may be pres-
ent on the frame.

The frame  is hung onto the firebox via the
two upper hanging brackets and then
secured to the firebox via the two lower
knurled fixing bolts, which are inserted
through the holes in the lower frame mount-
ing brackets after the frame is in position. See
diagrams to the right and below.  

L23 Chesire models and P23 Enigma models:
Remove the glass facia panel from any pro-
tective packaging. The glass facia panel is
supported by four M6 screws which protrude
from the front of the outer casing. 
Ensure each screw is unscrewed approxi-
mately one turn from the fully screwed in
position in order to create a 2mm gap
(shown). 
Simply hang the facia panel onto the outer
casing ensuring that the corresponding key-
hole shaped holes engage the screwheads
fully.

P23 Enigma models:
To fit the decorative corner columns, ensure
the main glass facia is mounted in position.
Remove any transit tape and unscrew  the
front clamping disc and remove. 

Compress the column assembly and position behind the glass panel, lining up with the appropriate hole. Release
the assembly  when in position and secure in place by refitting the front clamping disc.

7

8.4

L23 Chesire models and P23 Enigma models

Compress the

assembly

Front clamping disc

P23 Monet Trio models

Содержание L23 BLACK

Страница 1: ...ser for safekeeping Revision A 03 08 Country s of destination GB IE L23 CHESHIRE P23 MONET TRIO P23 ENIGMA FLUELESS GAS FIRE Focal Point Fires plc Christchurch Dorset BH23 2BT Tel 01202 499330 Fax 012...

Страница 2: ...L23 Cheshire P23 Monet trio P23 Enigma silver glass...

Страница 3: ...fire This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume in ft3 by 35 3 This app...

Страница 4: ...only in a sufficiently ventilated space A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibility...

Страница 5: ...is common however other rooms such as kitchens dining rooms and hallways are permitted providing a suitable natural gas supply is available and rooms sizing and ventilation requirements are strictly a...

Страница 6: ...s etc be positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should b...

Страница 7: ...met 1 Fitting template GAS SUPPLY ROUTES There are four possible entry points for the gas supply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas c...

Страница 8: ...p wall plugs taking care to leave the screws protruding approximately 5mm from the wall Now hang the appliance onto these screws through the two key hole shaped holes in the back panel of the applianc...

Страница 9: ...If under any circumstances the piezo electric spark fails the pilot cannot be lit man ually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burne...

Страница 10: ...ve packaging The glass facia panel is supported by four M6 screws which protrude from the front of the outer casing Ensure each screw is unscrewed approxi mately one turn from the fully screwed in pos...

Страница 11: ...detailed in section 8 4 13 Check the purpose provided ventilation is un obstructed 14 Light the fire and test setting pressures 15 Check safe operation of the appliance For specific servicing instruct...

Страница 12: ...ed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per m...

Страница 13: ...tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If th...

Страница 14: ...dicator bracket Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fi...

Страница 15: ...dis colouration may occur over time The appliance must not be positioned vertically within 100 mm of a carpeted floor rugs or fabric materials of any kind This dimension is measured vertically to the...

Страница 16: ...y device ODS If the appliance shuts down during use for no apparent reason then several reasons may be suspected If a door or window has been opened creating a draught then pilot disturbance could be...

Отзывы: