FLUE SPILLAGE MONITORING SYSTEM
This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no apparent reason
then several reasons may be suspected. If a door or window has been opened creating a draught, then pilot
disturbance could be the problem, and removal of the draught should resolve this. The fire can then be re-lit in
accordance with the previous section. A grommet seal may also be missing from the firebox causing abnormal
draught to shut down the pilot. Call your installer to check seals are properly fitted.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF,
call in your installer to check the flue and ventilation and carry out any remedial work required. DO NOT allow
the appliance to be used until the flue system is passed as safe.
CLEANING
Before carrying out any of the following operations, ensure that the fire is OFF and completely cold.
Debris that may form on the firebed should be periodically removed by a competent person. Large deposits
could indicate deterioration of the flue. This should be repaired by a competent person, and the fire serviced
before further use.
FIREFRONT - Any dust accumulating in the firefront may be removed using a vacuum cleaner or dry cloth. Heavy
stains may be removed by using a damp cloth and mild household detergent. Brass parts of the firefront may be
cleaned using a suitable brass cleaner. Replace the front centrally against the fire after cleaning.
PAINTED AREAS - These can be cleaned using a dry cloth.
COALS AND CERAMICS
See the relevant section in the Installation Guide of these instructions.
SERVICING
The fire and flue should be checked on an annual basis to ensure all of the product of combustion are entering
the flue and that there is no excessive build up of soot. The frequency of service will depend on usage, but MUST
be carried out at least once annually. Servicing must be carried out by a competent person, such as a CORGI
registered installer.
Cleaning of the coals may be carried out by following the instructions given in the Installation section. The
Installation instructions carry full servicing details for the use of the installer.
If debris from the flue or other foreign matter is found on the fire it may indicate a need for servicing. Do not use
the fire until the source of the debris has been found and rectified.
Air vents (where fitted) should be checked periodically to ensure they are free from obstruction.