TROUBLESHOOTING GUIDE

Fire sparks but pilot does not light

No gas to fire, check isolators are open.
Pipework blockage, clean out.
Air not fully purged, repurge supply or wait longer.
Spark earthing to metal work, reset gap correctly.
Blocked pilot, clean out internally.

Pilot lights but then goes out

Severe restriction in gas supply, clear obstruction.
Faulty thermocouple, replace pilot unit.
Hold control knob in for longer.
Check control knob does not foul data plate.
Missing grommets seal in firebox, replace

Fire does not spark at pilot

HT lead detached, refit.
Spark gap too large or small, reset correctly.
Faulty piezo unit, replace.
Debris shorting out electrode, clean.
Spark shorting to metalwork under tray, realign HT lead.

Fire runs for a time and then cuts off

Excessive room draught or flue pull, rectify.
Loose or faulty thermocouple, rectify.
ODS system in operation.
Firebox grommet seal not fitted, rectify.
Lint in pilot aeration hole, clean thoroughly internally

Pilot flame shrinks when fire is on high

Poor gas flow to fire, check pressure with fire on high.
If pressure is low, remove any restriction in pipework or valve.
Check all isolators are adequately sized and fully open.
Check meter pressure is adequate.
Air leak under base of firebox, rectify.
Lint in pilot aeration hole, clean thoroughly internally.
Firebox grommet seal missing, rectify

Fire smells when first lit or in use

Newness smell from brand new appliance.
Spillage occurring. Carry out spillage test and rectify any problems.
Low temperature sealants or combustible materials used in incorrect
positions.
Air leak under base of firebox, rectify
Firebox grommet seal missing, rectify.

15

15.0

Содержание JEMEZ

Страница 1: ...instructions must be handed to the user for safekeeping Revision B 11 03 Country s of destination GB IE Focal Point Fires plc Avon Trading Park Christchurch Dorset BH23 2BT 01202 499330 Fax 01202 4993...

Страница 2: ...a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instructions...

Страница 3: ...stalled in accordance with the rules in force and used only in a sufficiently ventilated space Consult all instructions before installation and use of this appliance This appliance is free from any as...

Страница 4: ...must be connected to only one fireplace and the flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the appli...

Страница 5: ...to BS 715 Pre cast block flue complying with BS 1289 Any existing under grate draught device must be sealed off The opening wall must be non combustible The appliance requires a hearth with non combu...

Страница 6: ...BEEN PREVIOUSLY USED FOR A SOLID FUEL OR OIL BURNING APPLIANCE X Dimension 60mm VENTILATION No purpose provided ventilation is normally required for this appliance The requirements of other appliances...

Страница 7: ...allow plugs and screws to secure installation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note...

Страница 8: ...milar Place the coals ceramics and fixings safely to one side Remove the burner from the assembly by removing the two screws in the data control plate Lift away the plate and remove the two screws ret...

Страница 9: ...ame or base and relevant points in the opening or on the wall Rawlplugs will be required NOTE Plastic rawlplugs are not suitable for this application Gas supply Following preparation for the fixing me...

Страница 10: ...ill prevent proper installation after servicing Coil up the surplus cable and tuck the coils out of the way as suggested in the photograph FITTING THE BURNER TRAY Important Note Check that the thermoc...

Страница 11: ...the supports in the matrix over the top of the holes Ensure the coals are not turned sideways such that they actually enter the holes Finally place the rear row of two coals Note The coals must not b...

Страница 12: ...he gas supply up to the fire for any leaks in accordance with current Approved Codes of Practice ACOPs OPERATING THE APPLIANCE The pilot is visible through the left hand side of the matrix Rotate the...

Страница 13: ...is to be suspected This will be dirt and debris kinked or inadequate size pipes restriction in a fitting or solder flashing across a joint FLUE SPILLAGE MONITORING SYSTEM This fire is fitted with a fl...

Страница 14: ...rried out at least one annually Advise that cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces Scratched and other superficial damage to...

Страница 15: ...p ceramic components in plastic bags and dispose at proper refuse sites as directed Re fit the coals by referring to the relevant section of these instructions DISMANTLING THE BURNER TRAY Remove the t...

Страница 16: ...frame and if necessary replace Refitting of the convector box is as described in the fitting section of these instructions PILOT ASSEMBLY Remove the burner tray as in relevant section and pilot unit a...

Страница 17: ...uns for a time and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration...

Страница 18: ...ung children the elderly or infirm are concerned Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper may discolour if fitted too close to the...

Страница 19: ...irements this will have been carried out by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force OPERATING INSTRUCTIO...

Страница 20: ...ed using a vacuum cleaner or dry cloth Heavy stains may be removed by using a damp cloth and mild household detergent Brass parts of the firefront may be cleaned using a suitable brass cleaner Replace...

Отзывы: