INSTALLATION REQUIREMENTS
Compatible wall thicknesses for the Installation Methods detailed in this Guide are as follows;
Note: These dimensions are between the surface of the marble/backpanel and the surface of the outside wall.
Internal
This appliance MUST NOT be installed into a room containing a bath or shower, or where steam may be
present. The firebox must be installed onto a suitable non-combustible insulating surface at least 12mm thick,
covering the entire base area of the box. This appliance is suitable for use with a “lightweight” surround and back
panel of 150ºc minimum rating. A suitable gas supply and an electrical 3 Amp fixed fused spur are both required
near the intended appliance site.
External
Please refer to the diagram on the following page for more details of the most suitable site for the fan terminal.
The terminal must be located so that the outlet is not obstructed in any way allowing poor disposal of
combustion products. A safety cage should be fitted in place over the terminal to ensure compliance with
Byelaws. Terminals located in passageways between two properties, public footpaths or which might discharge
over the same may be subject to local Byelaws on items such as minimum distances for projection. In these
circumstances it is the installers responsibility to check that the location of the terminal does not infringe any
Byelaws. If in any doubt about flue terminal location, especially with regards to garages and car ports then further
advice should be sought from CORGI or the manufacurer.
2
APPLIANCE DATA
Gas Group
G20 Natural Gas CAT I2H
Inlet Pressure
20 mbar
Max Energy Input (gross)
6.8 kW
Min Energy Input (gross)
3.5 kW
Pilot Energy Input (gross)
210 W
Setting Pressure
14.8 mbar
Main Injector Burner
Stereo size 81
Gas Inlet Connection
8mm compression
Ignition
Piezo spark
Spark Gap
3.5 to 4.5mm
Electrical Supply
230V~50Hz (ac)
Current Rating
0.3A running, 0.4A on start up
Fuse Rating
3 Amp
Approximate Weight
Fire Unit 20Kg, Fan Unit 12Kg
Flue Specification
Twin walled circular section flue tube provided
with appliance. No additional or alternative flue
may be used. Outer flue tube diameter 120mm
See Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance
Data Badge, and is for decorative purposes.
2.0
3.0
* These dimensions allow for 25mm Rockwool insulation jacket
,
other forms of insulation may require adjustment.
Surface mounted firebox/surface mounted fan terminal.*
60mm
560mm
Surface mounted firebox/recessed fan terminal.*
150mm 650mm
Recessed firebox/surface mounted fan terminal.
265mm 765mm
Recessed firebox/recessed fan terminal.
355mm 855mm
Min
Max