This is a High Efficiency, Flueless, Inset Live Fuel Effect appliance.  It provides radiant and con-

vected warmth both efficiently and safely utilising the latest type catalytic converter burner

technology.

The fire incorporates a thermostatically controlled gas valve which can be adjusted by the

control knob on the front of the gas valve.  The fire is designed to reduce its heat output as

the temperature in the room in which it is installed rises.  The main burner will automatically

switch from low to pilot as the room temperature continues to rise. As the room temperature

cools the main burner will switch from pilot to low and then adjust its input as required.

This fire incorporates a combustion monitoring system (Oxygen Depletion Sensor). It must

not be adjusted or put out of operation. If replaced then manufacturers original parts must be

used.

The fire is designed to fit various types of situations as listed in the Installation Requirements.  

This appliance must be installed in accordance with the rules in force and only used in a suf-

ficiently ventilated space.  A minimum of 100cm

2 (

(15.5 in

2

) purpose provided ventilation is

required for this appliance, an openable window or louvre is also required. This appliance is

factory set for operation on the gas type, and at the pressure stated on the appliance data

plate.

The room size should be a minimum of 30m

3

(1059ft

3

) to allow adequate circulation of air and

ensure the correct operation of the fire when installed in a living room. This volume may

include adjacent spaces but these spaces must not be separated by a door. In order to con-

vert from cubic feet (ft

3

) to cubic metres (m

3

) divide the room volume (in ft

3

) by 35.3.

The appliance must not be installed in a bedroom, bathroom or any sleeping area.  The appli-

ance does not require a flue system of any type as the catalytic converter cleans the com-

bustion products to provide a complete combustion system which is intrinsically safe.

The  appliance  must  be  installed  by  a  competent  person  in  accordance  with  Gas  Safety

(Installation and Use) Regulations 1998 or rules in force. It is strongly recommended that a

CORGI registered engineer is used for this purpose as they are the only persons approved by

the HSE under the above regulations.

On initial lightup of a new appliance, the ‘newness’ will very quickly burn off within the first

5 minutes of operation. During this period some smoke may be emmited from outlet louvres,

this should be no cause for concern. Accordingly, the room should be well ventilated with all

windows and doors open during this period.

Read all these instructions before commencing installation.

Содержание Centrurion 30

Страница 1: ......

Страница 2: ...ntilation is required for this appliance an openable window or louvre is also required This appliance is factory set for operation on the gas type and at the pressure stated on the appliance data plat...

Страница 3: ...f ficiently ventilated space Consult ALL instructions before installation and use of this appliance This appliance is free from any asbestos material Refractories and coal bed are constructed from cer...

Страница 4: ...purpose made opening in the inner leaf of a cavity wall or a disused conventional fireplace opening Bridging the cavity may cause unwanted moisture to track to the inside of the house from the cavity...

Страница 5: ...sed with this appliance must be adequately sealed to the wall and floor to prevent excess draughts from around the back of the fire The temperature rating of any surround used must be 150 C A combusti...

Страница 6: ...E E I IN NS ST TA AL LL LA AT TI IO ON N N No ot te e E En ns su ur re e t th ha at t t th he e g ga as s s su up pp pl ly y i is s i is so ol la at te ed d b be ef fo or re e c co om mm me en nc ci i...

Страница 7: ...n c co om mb bu us st ti ib bl le e i in ns si id de e w wa al ll l T Th hi is s m me et th ho od d r re eq qu ui ir re es s n no o m mo od di if fi ic ca at ti io on ns s t to o t th he e i in nt te...

Страница 8: ...a qualified professional or local building control officer is essential to confirm this Mark out the area of the proposed fireplace opening on the wall Obtain a suitable concrete or steel lintel from...

Страница 9: ...rames of the inner leaf and the appliance posi tioned accordingly Wires and pipes that run within the wall must also be taken into account I In ns st ta al ll la at ti io on n a as s p pe er r m me et...

Страница 10: ...s possible without excessive heat loss es when the fire is off G GA AS S S SU UP PP PL LY Y When the opening is ready for installation of the fire the gas supply can be routed via knockout holes exam...

Страница 11: ...ab bl le e M MU US ST T N NO OT T b be e c cu ut t o of ff f a as s t th hi is s w wi il ll l p pr re ev ve en nt t p pr ro op pe er r i in ns st ta al ll la at ti io on n a af ft te er r s se er rv v...

Страница 12: ...h he e f fi ir re eb bo ox x s si id de es s o or r f fo or rw wa ar rd ds s t to ow wa ar rd d t th he e g gl la as ss s d do oo or r I If f t th hi is s i is s t th he e c ca as se e t tu ur rn n t...

Страница 13: ...il reaching the stop press down and hold for 5 seconds only pilot gas is flowing Continue pressing down the knob while turning further to the left to activate the piezo spark continue to hold the knob...

Страница 14: ...onnect the manometer and refit the test nipple screw Light the fire and check for gas soundness B BR RI IE EF FI IN NG G T TH HE E C CU US ST TO OM ME ER R All instructions must be handed to the user...

Страница 15: ...and clean with a soft brush Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot head Check the aeration holes are free from lint or dirt The pilot...

Страница 16: ...e er ra at tu ur re e m ma ay y d da am ma ag ge e s so om me e t ty yp pe es s o of f g ga as s a an na al ly ys se er rs s I If f i in n d do ou ub bt t c co on ns su ul lt t t th he e e eq qu ui ip...

Страница 17: ...e the output of the fire down to pilot as the room temperature falls the main burner will relight Ensure room sizing and ventilation are adequate See Section 3 1 and 4 1 Loose or faulty thermocouple r...

Страница 18: ...hot during use It is recommended that a suitable fireguard conform ing to BS 6778 or BS 6539 is used especially where young children pets the elderly or infirm are concerned The manufacturer of this...

Страница 19: ...ediate vicinity of the appliance must not be used as it may adversely effect performance of the combus tion monitoring system ODS system The requirements of other appliances operating in the space or...

Страница 20: ...ch the appliance OFF call in your installer to check the appliance and ventilation Remedial work must be carried out as required DO NOT allow the appliance to be used until the appliance and installat...

Страница 21: ...ustion matrix FB004030 0 Ceramic side cheeks FB004050 0 Ceramic brick panel FB004225 5 Glass door assembly FT004135 5 Convector Hood FT003710 5 Pilot assembly FT003835 5 Burner tray Please enquire Gas...

Отзывы: