This is a High Efficiency, Flueless, Inset Live Fuel Effect appliance. It provides radiant and con-
vected warmth both efficiently and safely utilising the latest type catalytic converter burner
technology.
The fire incorporates a thermostatically controlled gas valve which can be adjusted by the
control knob on the front of the gas valve. The fire is designed to reduce its heat output as
the temperature in the room in which it is installed rises. The main burner will automatically
switch from low to pilot as the room temperature continues to rise. As the room temperature
cools the main burner will switch from pilot to low and then adjust its input as required.
This fire incorporates a combustion monitoring system (Oxygen Depletion Sensor). It must
not be adjusted or put out of operation. If replaced then manufacturers original parts must be
used.
The fire is designed to fit various types of situations as listed in the Installation Requirements.
This appliance must be installed in accordance with the rules in force and only used in a suf-
ficiently ventilated space. A minimum of 100cm
2 (
(15.5 in
2
) purpose provided ventilation is
required for this appliance, an openable window or louvre is also required. This appliance is
factory set for operation on the gas type, and at the pressure stated on the appliance data
plate.
The room size should be a minimum of 30m
3
(1059ft
3
) to allow adequate circulation of air and
ensure the correct operation of the fire when installed in a living room. This volume may
include adjacent spaces but these spaces must not be separated by a door. In order to con-
vert from cubic feet (ft
3
) to cubic metres (m
3
) divide the room volume (in ft
3
) by 35.3.
The appliance must not be installed in a bedroom, bathroom or any sleeping area. The appli-
ance does not require a flue system of any type as the catalytic converter cleans the com-
bustion products to provide a complete combustion system which is intrinsically safe.
The appliance must be installed by a competent person in accordance with Gas Safety
(Installation and Use) Regulations 1998 or rules in force. It is strongly recommended that a
CORGI registered engineer is used for this purpose as they are the only persons approved by
the HSE under the above regulations.
On initial lightup of a new appliance, the ‘newness’ will very quickly burn off within the first
5 minutes of operation. During this period some smoke may be emmited from outlet louvres,
this should be no cause for concern. Accordingly, the room should be well ventilated with all
windows and doors open during this period.
Read all these instructions before commencing installation.