This fire is supplied with a particular style of fire front. Use of the fire front will ensure an adequate airflow
under the firebox for the correct functioning of this appliance. Compliance with safety standards cannot be
guaranteed when another style of front is used.
CCLLEEAARRAAN
NCCEESS TTO
O CCO
OM
MBBU
USSTTIIBBLLEESS
A non-combustible shelf may be fitted to within 100mm of the top edge of the fire frame. However the items
placed on it must also be able to withstand high temperatures.
A combustible shelf may be fixed to the wall above the fire, providing that is complies with the dimensions
given below.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the frame of the
appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible sidewalls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances any decorations soft furnishings and wall coverings (i.e. flock, blown vinyl and
embossed paper) positioned too close to the appliance may discolour or scorch.
VVEEN
NTTIILLAATTIIO
ON
N AAN
ND
D RRO
OO
OM
M SSIIZZEE
Purpose provided ventilation of 100cm
2
is required for this appliance. An openable window or louvre is also
required.
Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Ventilation fitted under, or within
immediate vicinity of the appliance must not be used as it may adversely effect performance of the combus-
tion monitoring system (ODS) system.
The requirements of other appliances operating in the space or room must be taken into consideration when
assessing ventilation requirements, this will have been carried out by your CORGI registered installer.
A supply of fresh air into the room is advisable to maintain temperatures within limits.
The appliance MUST NOT be installed in a bedroom, bathroom or any sleeping area.
For Republic of Ireland, see relevant rules in force.
The room size should be a minimum of 30m
3
to allow adequate circulation of air and ensure the correct oper-
ation of the fire. This volume may include adjacent spaces, but these spaces must not be seperated by a door.
O
OPPEERRAATTIIN
NG
G IIN
NSSTTRRU
UCCTTIIO
ON
NSS
The pilot is visible through the small hole in the left hand side
of the coal bed front edge.
Turn the thermostat knob to position 6
Turn control knob slightly left towards the ignition position until
reaching the stop, press down and hold for 5 seconds (only
pilot gas is flowing)
Continue pressing down the knob while turning further to the
left to activate the piezo spark, holding the knob down for a
further 10 seconds after the pilot has been lit. If the pilot does not light repeat the previous steps.
2
2
M
Maaxxiim
muum
m ddeepptthh ooff sshheellff
M
Miinniim
muum
m ddiissttaannccee ffrroom
m hheeaarrtthh ttoo uunnddeerrssiiddee ooff sshheellff
180mm
850mm
100mm
790mm
22..00
33..00
44..00
55..00