Installation
4.1 Safety instructions for Mounting and Installation
IMPORTANT!
Never install or apply damaged products. Claims concerning damages must be made to the carrier
immediately.
IMPORTANT!
Work in the connection with installations, start up, and maintenance on the FOAMICO cleaning systems
should only be done by authorized electricians, because the valid national regulations concerning prevention
of working accidents. (e.c. high voltage regulations: EN 60204, VBG4 DIN-VDE 0100/0113/0160) must be
respected. In cases of irregular installations there is a risk for major damages on both material and people.
4.2 Location and Mounting
The system should always be located in a frost-free room. Stationary system must always be mounted where
the surfaces are of solid quality, and when applicable the fastening must always be done with the delivered
bolts and raw plugs. Holes for wall brackets must be drilled according the dimensional drawing.
The Main Station should be connected to an adequate pipe system. This should correspond to distance from
the water supply, the maximum water flow and vertical distance from the boosting System.
4.3 Water supply
ATTENTION! Connection to water supply should always be done in according to local and national
standards.
If the legislation in your country requests safeguards for reverse current, this must be provided for.
WARNING
Due to the nature of low pressure cleaning systems Pressure surges can occur. The installer is responsible for
dimensioning the supply line to be able to adapt Pressure surge.
BEFORE mounting the system, the piping must be flushed with water in order to remove possible parts or
dirt.
ATTENTION. At the supply pipe to the main station a valve and filter must be installed. We recommend
using Original FOAMICO installations set. The water should be connected to the inlet shown in
POS A
. fig.
5.1
ATTENTION! The pump must be filled with water and vented. If the pump runs dry it may be damaged.
Open the vent valve
POS. L
fig. 5.1, until all air is out of the pump.
AFTER mounting the system flushing of the pipes must always be done with the system in “rinsing mode”,
to avoid any impurities in the injector system. Please keep rinsing until the rinsing nozzle shows an
invariable clean water jet coming out.
4.4 Electrical Supply