![FOAMICO 7011613 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/foamico/7011613/7011613_operation-manual_2313315016.webp)
16
MO 0145-4 NEXT 701613-18_UK
15-04-2019
power supply. If the green light at the pump is illuminated and the pump is not running investigate the flow
switch. Is the pump still not running call a service technician.
6.2.2 The pump will not stop
The pump does not stop. Investigate the following:
Check for water leakages in the pipe system
Check the non-return valve
Check the flow switch
Reset the unit. Turn the Handle
POS. D
fig 5.1 into
position for 5 seconds. Turn the Handle
POS. D
fig
5.1 into rinse position
. If the problem is still not solved, contact service technician.
6.2.3 Red light illuminated at the pump
The pump does not start or has suddenly stopped and the red light is illuminated, then investigates the
following:
-
Dry run
–
Limit 1 exceeded:
Is the supply pressure higher than 2 bar?
Limit 1 exceed
: The inlet pressure has been lower than 0,6 bar for more than 3 seconds.
Check the water supply. Minimum supply is 2,0 bar at full flow.
Reset the unit. Turn the Handle
POS. D
fig 5.1 into
position for 5 seconds. The unit will start when
there is water consumption
Follow the instruction at the display to set it back to the home screen, fig. 5.2