FOAMICO 7011613 Скачать руководство пользователя страница 22

 

22  

MO 0145-4 NEXT 701613-18_UK 

15-04-2019 

QTY. 

NO: 

Description 

Description1 

Beschreibung 

1000361 

Flow switch 

1" RG female 

Strömungsschalter  

1000378 

Elbow reduction 

1" -3/4" 

Winkel Reduzierstück 

1002169 

Nipple piece 3/4" 

110mm 

Nippel 3/4" 

1000550 

Proximity sensors 

NO/NC 

Annäherungssensor 

1000566 

filter Ø25 

RS 1500 - 500 my 

Filter Ø25 

  

1001040* 

3 Injector block complete 

Mobil Model 1 

3 Injektor- Block komplett 

  

1001041* 

3 Injector block complete 

Mobil Model 2 

3 Injektor- Block komplett 

  

1001042* 

3 Injector block complete 

Mobil Model 3 

3 Injektor- Block komplett 

  

1001043* 

3 Injector block complete 

Mobil Model 4 

3 Injektor- Block komplett 

1001044 

3 Injector block complete 

Mobil Model 5 

3 Injektor- Block komplett 

1000718 

Union 

for block 

Verschraubung  

1001969 

Base for 

Mobile station NEXT 

Grund rahmen 

1000417 

Vibration damper 

M8 x 2 

Schwingung Dämpfer 

1000345 

Canister holder 

large mobile 

Kanister Halter 

1000379 

Quick connect coupling 

3/4" Female 

Schnellkupplung 

1000340 

Rear wheel 

Ø250-60-Ø25 

Rad Groß 

1000341 

Front wheel 

Ø 100 

Rad lenkbar 

1000619 

Connection piece 

3/4" RG male - 3/4"RG Female 

Adapter 

1700058 

Safety valve 

1/4" male 

Sicherheit Ventil 

1000077 

Nipple 1/2" 

 40mm 

Nippel 1/2" 40mm  

1000189 

Male elbow 90 degrees 

1/2" RG 

Winkel 90° - 1/2" RG 

1000471 

Flexible Coupling 

1-1/4" Victaulic 

Klemmen für pumpen 

1000749 

Bracket f. El - box 

MSC 0106 

Halter für Schaltkasten 

1000105 

T- peace 

1/2"-1/2"-1/2" 

T-Stück 

1002167 

Inlet pipe PJE 

40 bar 

Eingang Rohr PJE 

1001069 

Compressor 

B 100 

Kompressor 

1700138 

Labels 

Set 

Symbole 

1001120 

Nozzle 

Holder 5 pc. 

Düse Halter 

1001263 

Control switch for 

2 pressure system 

Kontrollschalter für 

1000886 

Cable for 

Proximity sensors 

Kabel für 

1001246 

Bracket f. block 

Mobile system 

Halter für Schaltkasten 

1001831 

El-control box 

Pump-Comp 3  x 400V 

Schaltkasten für 

1700064 

T - Piece Female-Female-male 

1/4" 

T-Stück BSPP-BSPP-BSPT 

1001488 

Air regulator comp. with bracket 

For Mobile system 

Luftregler Komp. mit Halterung 

1001489 

Air hose 

Ø8/6 - PTFE- L=2,1m 

Luftschlauch 

1002069 

T- Nipple tube 

1"- 1/2"- 1" L=200mm 

T-Stück 

1001588 

Elbow  

Ø8 - 1/4" RG 

Winkel 

1001954 

Pump w. Saver motor 

CRNE 1- 23-HS-GI-E-HQQE- 6kW 

Pumpe m. Saver Motor 

1000494 

Hex Bolt 

ISO 4017 - M10 x 20-N 

Schraube 

1001971 

Cabinet 

Mobile 40 bar 

Gehäuse Mobile 

1000184 

Hex bolt 

ISO 4017 - M12 x 40 

Schraube 

1000183 

Washer 

DIN 125 -A 13 

Unterlegscheibe 

1000191 

Nut torque 

ISO - 10511 - M12 

Mutter 

1001975 

Front plate 

mobile station 

facade platte 

1000495 

Washer 

DIN 125 -A 6,4 

Unterlegscheibe 

1002168 

Outlet pipe for 

Next mobile 

Ausgang Rohr 

1000459 

Top profile for 

Mobile 40 bar 

Oberteil 

1000433 

Pressure transmitter 

1/2" ( 0-60 Bar) 

Druckmessumformer für Ausgangsdruck 

1000458 

Reinforcements profile 

Mobile 40 bar 

Rahmenunterzug 

1000481 

Washer 

DIN 125 -A 8,4 

Unterlegscheibe 

1000385 

Nut torque 

ISO - 10511 - M8 

Mutter 

1001795 

Hex Bolt 

ISO 4017 - M6 x 10 

Schraube 

1000756 

Nut torque 

ISO - 10511 - M6 

Mutter 

13 

1000334 

Button Head Screw 

ISO 7380 - M6 x 10 - 10N 

Schraube 

1000496 

Washer 

M10 x 40 x 1,5mm 

Unterlegscheibe  

1000583 

Button Head screw 

ISO 7380 - M4 x 10 

Schraube 

1001725 

Button Head Screw 

ISO 7380 - M6 x 12 

Schraube 

1000832 

Pressure transmitter 

1/2" male 25bar 

Druckmessumformer 

1002031 

Air release v. - PT1000 temp 

1/2" 

Luft V.- PT1000 temp  

 
Table 9.2

 Mobile unit with compressor spare parts 

 

 

Содержание 7011613

Страница 1: ...1 MO 0145 4 NEXT 701613 18_UK 15 04 2019 Operation Manual FOAMICO NEXT Mobile station with Compressor MO 0145 4 7011613 Mobil station without Compressor X AIR MO 0145 4 7011618...

Страница 2: ...Spray disinfection 11 5 5 Stop of operation 12 6 Troubleshooting Failures 15 6 1 Troubleshooting 15 6 2 Failures control system 15 6 2 1 The pump does not start 15 6 2 2 The pump will not stop 16 6 2...

Страница 3: ...compressor 30 9 9 Spare parts Air regulator complete with bracket 1001488 31 10 Electrical diagram 32 10 1 Spare parts Control box compressor 1001492 33 10 2 Flow diagram MS0145 0 MS0145 5 With compre...

Страница 4: ...tear as well as damage on parts which can be related to negligent or wrong treatment are not covered by this guarantee This guarantee does not cover at all if the system has been exposed to frost This...

Страница 5: ...nd maintenance of it Never direct the water jet towards persons Make sure that the couplings lock when the hose and nozzles are connected Always follow this procedure before use Always depressurize th...

Страница 6: ...s Any other kind of application or use beyond this is considered to be inappropriate and deviant concerning the requirements and may lead to dangerous situations FOAMICO is not liable for any sequenti...

Страница 7: ...am disinfection Rinsing Foam Cleaning e g acid Foaming Foam Cleaning e g Alkaline Spray disinfection 3 2 Models FOAMICO supplies this NEXT Mobil Unit in 6 different versions The actually version can b...

Страница 8: ...8 MO 0145 4 NEXT 701613 18_UK 15 04 2019 3 3 Model Overview Typ 1 MO 0145 1 Typ 2 MO 0145 2 Typ 3 MO 0145 3 Typ 4 MO 0145 4 Typ 5 MO 0145 5 Typ 0 MO 0145 0...

Страница 9: ...orrespond to distance from the water supply the maximum water flow and vertical distance from the boosting System 4 3 Water supply ATTENTION Connection to water supply should always be done in accordi...

Страница 10: ...ATTENTION The voltage and frequency is marked on the main station s and the pumps nameplates Make sure they are suitable for the electricity supply of the installation site 4 5 Supply of Detergent an...

Страница 11: ...t the rinsing nozzle or rinsing pipe in the coupling at the low pressure valve gun marked with blue or green protection 2 set the handle POS D fig 5 1 in rinse position 3 The system is now ready for r...

Страница 12: ...S D fig 5 1 back in rinse position when Foam operation is ended 6 ATTENTION Before choosing another cleaning operation with another chemical the system must be flushed with clean water for at least 30...

Страница 13: ...upply B Compressed air connection D Handle for selecting operation E Connection for hose Rinse and foam F Advanced control panel G connection for limiting nozzles Adjust concentrations H Pressure redu...

Страница 14: ...0 bar Inlet pressure Actual measured inlet pressure Liquid temp water temperature in top of the pump FIGURE 5 3 Display photo Pump running Discharge press Actual discharge pressure from pump maximum s...

Страница 15: ...container Change to new chemical container Suction filter above fluid level in the chemical container Lead the suction filter underneath the fluid level No compressed air to the system Open the air in...

Страница 16: ...le POS D fig 5 1 into rinse position If the problem is still not solved contact service technician 6 2 3 Red light illuminated at the pump The pump does not start or has suddenly stopped and the red l...

Страница 17: ...Reset the unit Turn the Handle POS D fig 5 1 into position for 5 seconds The unit will start when there is water consumption Follow the instruction at the display to set it back to the home screen fi...

Страница 18: ...ngs Always make sure there is a nozzle or lance mounted in the coupling before opening Rinsing through an open coupling can damage the O rings 7 5 Ball valves Every ball valve on the inlet for water i...

Страница 19: ...urrent with compressor Foam A 14 8 11 6 A Nominal current without compressor A 14 3 11 1 A Fuse A 16 Dimension mm2 2 5 Dimensions WxHxD mm 725 x 1225 x 985 Weight with compressor kg 150 Weight without...

Страница 20: ...20 MO 0145 4 NEXT 701613 18_UK 15 04 2019 9 Spare parts 9 1 Enclosure Mobile unit MO 0145 4 With and without compressor Figure 9 1 Mobile station enclosures...

Страница 21: ...21 MO 0145 4 NEXT 701613 18_UK 15 04 2019 9 2 Overview Mobile unit MO 0145 4 with compressor Figure 9 2 Overview Mobile unit with compressor...

Страница 22: ...r 5 pc D se Halter 1 1001263 Control switch for 2 pressure system Kontrollschalter f r 2 1000886 Cable for Proximity sensors Kabel f r 1 1001246 Bracket f block Mobile system Halter f r Schaltkasten 1...

Страница 23: ...23 MO 0145 4 NEXT 701613 18_UK 15 04 2019 9 3 Overview Mobile unit MO 0 5 without compressor...

Страница 24: ...tem Halter f r Schaltkasten 1 1001831 El control box Pump Comp 3 x 400V Schaltkasten f r 1 1002069 T Nipple tube 1 1 2 1 L 200mm T St ck 1 1001954 Pump w Saver motor CRNE 1 23 HS GI E HQQE 7 5kW Pumpe...

Страница 25: ...l valve and quick coupling QTY Part Number Description Description1 Beschreibung 1 1000069 Ball valve 1 2 RG female female Kugelhahn 1 2 1 1000037 Quick connect coupling 1 2 RG male Schnellkupplung 1...

Страница 26: ...26 MO 0145 4 NEXT 701613 18_UK 15 04 2019 9 5 Spare parts Rinse and foam block 1001040 44 1001218 Figure 9 5 Spare parts pipe system foam and rinse circuit...

Страница 27: ...ll gasket Stopfen und Halter f r 1 1000520 Plug 1 4 RG 1 4 RG Verschlusskappe 1 1001002 Check valve 1 4 x 1 4 male male EPDM R ckschlagventil Luft 3 1001008 1 6 Injector for 3 Injector system 1 6 Inje...

Страница 28: ...28 MO 0145 4 NEXT 701613 18_UK 15 04 2019 9 6 Spare parts Rinse and foam block 1001309 13 Abbildung 9 6 Ersatzteile Schaum Sp lblock...

Страница 29: ...sket Stopfen und Halter f r 1 1001002 Check valve 1 4 x 1 4 male male EPDM R ckschlagventil Luft 3 1001008 1 6 Injector for 3 Injector system 1 6 Injektor f r 1 1001064 O Ring 31 47 x 1 78 O Ring 1 10...

Страница 30: ...ection MO 0145 5 1001044 1001675 1001008 Foam Foam Foam Table 9 7 Part no function block Positioning ring Injector Part No 1001673 Part No 1001674 Part No 1001675 9 8 Spare parts foam rinse block posi...

Страница 31: ...31 MO 0145 4 NEXT 701613 18_UK 15 04 2019 9 9 Spare parts Air regulator complete with bracket 1001488...

Страница 32: ...32 MO 0145 4 NEXT 701613 18_UK 15 04 2019 10 Electrical diagram...

Страница 33: ...mm2 Din Schiene Terminal grau 1 1700238 Din rail Terminal gray 4 0mm2 Din Schiene Terminal grau 1 1700239 Din rail Terminal black 4 0mm2 Din Schiene Terminal Schwartz 1 1700240 Din rail Terminal brown...

Страница 34: ...34 MO 0145 4 NEXT 701613 18_UK 15 04 2019 10 2 Flow diagram MS0145 0 MS0145 5 With compressor 10 3 Flow diagram MO 0145 1 5 without compressor...

Страница 35: ...or rinse and foam Components 1 Flow switch 3 Pump 4 Temperature transmitter TP1000 5 Check valve water 6 Pressure gauge 7 Pressure transmitter 8 Check valve water 9 Rinse foam block 10 Check valve che...

Страница 36: ...019 11 Name plate 1 Company Name 8 Maximum pressure 2 Production date 9 Min Max inlet pressure 3 Serial number 10 Power 4 Item Number 11 Current 5 Model type 12 Voltage 6 Maximum allowed flow 13 Frequ...

Страница 37: ...50 27 F B 050 27 C B 065 27 F B 065 27 C B 100 27 F B 100 27 C B 120 27 F B 120 27 C B 200 27 F B 200 27 C B 270 27 F B 270 27 C B 400 F B 540 F B 630 F B 630 F B 810 F B 1080 F B 060 45 F B 060 45 C...