Set:
to make the current parameters shown in the SNMP software activate.
Get:
to read the current device’s activating parameters and show them on SNMP software.
Ø
IP Out Enable
Check the checkbox with “√”, then the IP output is enabled, otherwise it is not. Users can
decide whether to open the IP output function or not.Users can modify the IP address here
as well.
Ø
IP Out Address/Service IP Address/Service Mask/Service Gateway
Users can set the address by modifying the value in these four fields.
Ø
ASI Output Channel
This device supports 1 MPTS (Multiple Programs Transport Stream) and 8 SPTS (Single
Programs Transport Stream) output. User can click
to triger a pull-down list to select the
output type.
Ø
Output Port
To set the
output port
by modifying the value in this field.
Ø
Original Network ID
This 16-bit field gives the label identifying the network ID of the originating delivery system.
The value ranges from 0 to 0xFFFF.
Ø
Transport Stream ID
This is a 16-bit field which serves as a label for identification of this TS from any other
multiplex within the delivery system. The value ranges from 0 to 0xFFFF.
Ø
Output Bit Rate (Mbps)
This includes the effective bit-rate of encoding channel 1-8, the effective bit-rate from ASI
input and the bit-rate of stuffed null packets.
Ø
UDP Stream TS Package
Users can set the amount of TS packages here.
Ø
NIT Insertion