Operation Manual EMGZ490A
30.08.2019
14
4.6
Description of LEDs
EMGZ490A.R EMGZ490A.W
LED
Meaning
LNK 1
Ethernet cable 1 connected with
other station
ACT 1
Blinking, if data communication on
Ethernet connection 1 active
LNK 2
Ethernet cable 2 connected with
other station
ACT 2
Blinking, if data communication on
Ethernet connection 2 active
BF
Permanent red if no RJ45 plug is
connected
Flashes red if communication to
PLC is interrupted
SF n.c.
RDY
Permanent green if power supply is
connected and processor works
Fig. 4: Signal LEDs
5
Integration in a PROFINET-network
The force measuring amplifiers of the EMGZ490A series were design to work in an
PROFINET-network whereas the amplifier acts as an IO-device (Slave) and die IO-
Controller (or PLC) as a master.
5.1
PROFINET Interface
PROFINET RT is supported. The corresponding communication profile will be selected by
the IO-controller (Master) via GSD. The EMGZ490A transmits the feedback value in Digit
and the Status/Error information Byte. In addition parameters like Offset feedback,
Gain feedback, Filter feedback, Filter analogue output and Scaling of the output can be