Operation Manual EMGZ 309.EIP
20.12.2018
22
6.4
Access to the Tension Values
After the integration of
the amplifier in the
network the tension data
are available in the
global input tags of the
controller and that in the
defined cycle time. In our
example the amplifier
was named
EMGZ309
.
The tension values can
therefore be found under
the controller tags
EMGZ309:I
>>
EMGZ309:I Data
Index 0
to 3. Where the values
are assigned to the
indices as follows:
Index
Value
0
inActualValueInADC -> Raw digital actual value not filtered.
1
inActualValueInN -> That is the actual value in Newton. This value
utilizes the output low pass filter.
2
inActualValueInLb -> That is the actual value in lb. This value utilizes
the output low pass filter.
3
inActualValueInUnit -> That is the actual value in the configured unit.
This value utilizes the output low pass filter.
4
inStatus -> That is the status of the actual value. Bit 0 set:
mechanically overloaded; Bit 1 set: output underflow; Bit 2 set:
output overflow
Fig. 15: RSLogix E309026