Operating Manual CMGZ432
32
11.3 Description of the parameters
The parameter changing mode will be activated by pressing the
↵
key for 3 seconds.
Generally, the parameters are settable using the keys as follows:
choose
switch the selections or increase / decrease numeric values
change the decimal (while inputting a numeric value)
enter
Find offset
Use:
The actual force value will be saved by pressing the
↵
key for 3
seconds. This is used to compensate the weigth of the material and the
roller. The determined value will be shown for 2 seconds and then
stored under parameter
Offset feedback.
Calibration feedback
Use:
In this parameter, using the
↑
↓
keys you can input the force value
referring to the calibration load you applied to the sensor (force
feedback value). The processor then calculates the actual gain value
and stores it under parameter
Gain feedback.
Notice: The input can be aborted with the
←
key. In this case the
previously saved value remains.
Range:
1
to
9999
Default:
1000
Increment:
1
Unit:
[N,kN]
Auto. diameter adjust
Use:
(Is displayed only if
pilot control
is set to
external
.)
By pressing the
↵
key for 3 seconds, an adjustment program is started
which will assign a diameter range to the 0...10V analog input signal
coming from a distance sensor, etc. (refer to „9.9 Setup of external pilot
control“)
Adjustment of pilot control
Use:
(Is displayed only if
pilot control
is set to
external
.)
By pressing the
↵
key for 3 seconds, an adjustment program is started
which will record the characteristic of the connected brake. (refer to
„9.9 Setup of external pilot control“)
↵
↑
↓
←
↵