Operating Manual CMGZ432
30
11 Parametrization
11.1 Parameter list
Parameter Unit
Default
Min
Max
Actual
Find offset
(Parameter function)
Calibration feedback
(Parameter function)
_______
Auto. diameter adjust
(Parameter function)
1)
Adjustm. of pilot control (Parameter function)
1)
Offset feedback
[Digit]
0
-4000
4000
_______
Gain feedback
[-]
1.000
0.100
9.000
_______
Nominal force
[N,kN]
1000
1
9999
_______
Unit of force
[N,kN]
N
N
kN
_______
Sensitivity [mV/V]
1.8
0.1
3.0
_______
1 or 2 sensors
[-]
1
1
2
_______
Lowpass output
[Hz]
50.0
0.1
200.0
_______
Lowpass instrument
[Hz]
1.0
0.1
10.0
_______
Lowpass display
[Hz]
1.0
0.1
10.0
_______
Scale instrument
[-]
1.00
0.01
10.00
_______
Limit 1 min / max
Min, Max
Max
_______
Limit value 1
[N,kN]
0
-9999
9999
_______
Limit 2 min / max
Min, Max
Min
_______
Limit value 2
[N,kN]
0
-9999
9999
_______
Language
English, German, French, Italian
_______
Pilot control
No, Internal, External
_______
Influence of PI
2)
[%]
100.0
0.1 100.0
_______
PID-configuration
2)
PI,
PID
PI
_______
Proportional P0
2)
[-]
1.00
0.01 100.00
_______
Integral I0
2)
[s] 1.00
0.01
100.00
_______
Derivative D0
2)
[s]
0.010 0.001
10.000
_______
Proportional P1
2)
[-]
1.00
0.01 100.00
_______
Integral I1
2)
[s] 1.00
0.01
100.00
_______
Derivative D1
2)
[s]
0.010 0.001
10.000
_______
Proportional P2
2)
[-]
1.00
0.01 100.00
_______
Integral I2
2)
[s] 1.00
0.01
100.00
_______
Derivative D2
2)
[s]
0.010 0.001
10.000
_______
Proportional P3
2)
[-]
1.00
0.01 100.00
_______
Integral I3
2)
[s] 1.00
0.01
100.00
_______
Derivative D3
2)
[s]
0.010 0.001
10.000
_______
Alarm limit error
[%]
10.0
0.1
100.0
_______
1)
Is displayed only if
pilot control
is active
2)
These parameters may be changed also while the controller is enabled. Setting is done
as written under „11.3 Description of the parameters“. The new values are taken for
the control loop when parameter mode is quit.