4.4
Edge Sensors
An optical sensor (AZS01) and an ultrasonic sensor (US01) is available from FMS.
Adjustment is done automatically.
4.5
Manual Sensor Adjustment
The manual sensor adjustment allows an easy positionning of the sensor across the whole
material width. Focussing of the sensor is kept.
4.6
Linear Units
The linear units are also used for sensor positioning but give much more comfort than the
manual one. The control unit automatically lets the sensors find the edge or the line across the
whole material width.
This kit contains 1 or 2 linear units with travel range according to customer specification, the
sensor mounting bracket and the necessary cables. The control unit detects automatically if 1
or 2 linear units are installed.
It is possible to define a fixed reference point (machine frame for example). Then, all position
values will refer to this reference point.
4.7
Remote Control Box
The remote control box simplifies resetting the machine for a new job. The position reference
can be adjusted with two keys on the box in 0.1mm steps. It enables the operator to stand
beside the machine and get a direct feedback when adjusting the lateral position.