Operating Manual BKS600A
31
Output config.
Use:
For the analog output (controller output) this parameter defines the output
signal range.
Range:
0...10V and 0...20mA,
Default:
0...10V
0...10V and 4...20mA,
and ±10V
0...20mA
Note:
The jumper for the tension output must match the settings of this
parameter. (ref. to „14.3 Jumper for the Analog Inputs / Outputs“)
Output direction
Use:
For the analog output (controller output) this parameter defines how the
control error is calculated. With this parameter, the polarity of the actuator
signal can be changed. Thus the meaning of control system changes too.
Range:
Standard,
Inverted
Default:
Standard
Base distance left
Use:
This parameter stores the distance from the reference point on the machine
frame to the reference point of the left linear unit.
Range:
0.0
to
5000.0
Default:
0.0
Increment:
0.1
Unit:
[mm]
Base distance right
Use:
This parameter stores the distance from the reference point on the machine
frame to the reference point of the right linear unit.
Range:
0.0
to
5000.0
Default:
0.0
Increment:
0.1
Unit:
[mm]
Digital input 1
Use:
This parameter defines which event is performed by the digital input 1.
Applying 24VDC to the input terminal for at least 100ms corresponds to
pressing the key on the operation panel.
The functions of the possible settings are equal to the special functions of
the web guide (ref. to „8.3 Main Operating Menu and Special Functions“).
Note:
If the digital input is set to „Automatic“, the web guide will be in
automatic mode as long as the digital input signal is on (permanent signal).
Range:
Automatic, Center Position, Reference –, Ref, Manual left, Manual
right, Start detection, Sensor freerun
Содержание BKS600A
Страница 9: ...Operating Manual BKS600A 9 6 Dimensions fig 3 Dimensions K600019e...
Страница 18: ...Operating Manual BKS600A 18 8 Operating 8 1 View of the Operating Panel fig 15 Operating panel BKS600A K600020e...
Страница 38: ...Operating Manual BKS600A 38 This page intentionally left blank...
Страница 45: ...Operating Manual BKS600A 45 This page intentionally left blank...