FMR BCS12V1A Скачать руководство пользователя страница 6

 

 

SPECIFICATIONS

 

 

1

 

Electrical Parameters

 

 

1-1 

Suit for battery type 

Lead acid and LiFePO4

 

1-2 

Suit for battery capacity 

2~30AH

 

1-3 

Rated charging current BCS12V/1A & BCS12V/1.5A 

1.0 /1.5 

Max.

 

2-1 

AC input voltage 

100~240 

 

2-2 

AC input power frequency 

50/60 

.

 

2-3 

Soft start charging current 

0.1/ 0.15 

 

2-4 

Soft start battery voltage is over (for Lead acid battery) 

1.0 

+/-0.2

 

2-5 

Soft start battery voltage is over (for LiFePO4 battery) 

6.0 

+/-0.2

 

2-6 

Bulk charge current BCS12V/1A & BCS12V/1.5A 

1.0 /1.5 

Max.

 

2-7 

Absorption charging voltage  

 

 

--Standard battery setting (Default setting) 

14.3 

+/-0.2

 

 

--Gel type battery 

14.1 

+/-0.2

 

 

--AGM type battery 

14.4 

+/-0.2

 

 

--WET type battery 

14.6 

+/-0.2

 

 

--Calcium type battery 

14.8 

+/-0.2

 

 

--LiFePO4 type battery 

14.5 

+/-0.2

 

2-8 

Absorption transits to Battery test or Float condition: 

 

 

--Charging current drops to  

0.2/0.3 

 

 

-- or Absorption charging timer timed out 

36 

 

2-9 

Battery test control point for next stage VB < 

12.8V 

 

2-10 

Maximum Recondition charging voltage control  

 

 

--Standard battery setting 

14.5 

+/-0.2

 

 

--Gel type battery 

14.4 

+/-0.2

 

 

--AGM type battery (default setting) 

14.7 

+/-0.2

 

 

--WET type battery 

15.5 

+/-0.2

 

 

--Calcium type battery 

16.0 

+/-0.2

 

 

--LiFePO4 type battery 

Skip this stage

 

2-11 

Float charging voltage for Lead acid battery 

13.6 

+/-0.2

 

 

Float charging voltage for LiFePO4 battery 

Skip this stage

 

2-12 

ECO charging control 

168 

 

2-13 

Pulse charge voltage 

 

 

--For lead acid battery (cut in and cut out) 

13.3~13.8 

+/-0.2

 

 

--For LiFePO4 battery 

14.5 

+/-0.2

 

Physical Parameters  

 

3-1 

Charger dimension 

100 (L) x 60 (W) x 35 (H) 

mm

 

3-2 

Output leads with ring terminal and clamps 

12 ft SPT-2 18AWG 105C 

300V

 

3-3 

Or Output leads with ring terminal and clamps 

6 ft SPT-2 18AWG 105C 

300V

 

3-4 

Or other customized leads 

 

3-6 

Net weight 

Approx. 400g

 

 

 

 

Environmental characteristics  

 

4-1 

Cooling method 

Natural cooling

 

4-2 

Operating temperature 

-10 ~ 40*C

 

4-3 

Storage temperature 

-25 ~ 85*C

 

4-4 

Operating Humidity range 

100% no condensation

 

 

Содержание BCS12V1A

Страница 1: ...ting instructions for this battery charger Please keep it with or near the charger at all times INTRODUCTION This battery charger is much more than just a charger but also a maintainer and battery con...

Страница 2: ...RING NORMAL BATTERY OPERATION IT IS IMPORTANT THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS To reduce risk of battery explosion follow these instructions an...

Страница 3: ...Be sure the area around battery is well ventilated while battery is being charged Gas can be forcefully blown away by using a piece of cardboard or other non metallic material as a fan b Clean batter...

Страница 4: ...TSIDE VEHICLE A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEAR BATTERY a Check polarity of battery posts POSITIVE POS P battery terminal usually has a larger diamete...

Страница 5: ...mum rated current to charge up the battery capacity over 80 Fault LED on Safety timeout after 72 hours of attempting to charge and the battery voltage cannot reach 14 0V then stop charge and indicate...

Страница 6: ...imed out 36 2 9 Battery test control point for next stage VB 12 8V 2 10 Maximum Recondition charging voltage control Standard battery setting 14 5 0 2 Gel type battery 14 4 0 2 AGM type battery defaul...

Страница 7: ...mode the LEDs will flash fast to indicate the corresponding battery type PROGRAMMING TABLE Default mode Blue and Yellow flashing GEL type lead acid Green and Yellow flashing AGM type lead acid Green a...

Страница 8: ...es not cover modification abuse exposure to extreme environments outside of the design specifications EG water or high temperatures neglect attempts to open repair or lightning damage Obtaining warran...

Отзывы: