Figure 6 - Framing Clearances
Figure 7 - Framing Firebox with “Z” Type
Ember Protectors
FireBox inSTALLATion
Continued
As Required by Design as Lon
g
as Ceiling Clearance Is Maintain
ed
53
7
/
8
"
(136 cm)
Min
.
44
5
/
8
"
(113 cm)
Min
.
Platform Must be
Solid, Flat and
Fully Supported
22
3
/
4
"
(58 cm
)
"Z" Type
Ember Protector
(Not Supplied)
Figure 5 - Mantel Clearances to Metal
Face
Front
Face
Fireplace Front View
Fireplace Side View
3" Nom.
(7.6 cm)
9" Min.
(22.8 cm)
12" Min.
(30.4 cm)
33°
6" Nom.
(15.2 cm)
1
1
/
2
" Max.
(3.8 cm)
Drywall
2" X 4" Stud
Combustible
Materials
Figure 4 - Mantel Clearances to
Combustible Materials
Seal Gaps with
Noncombustible
Mortar or Adhesive
Top View of Fireplace
Drywall
4"
(Approx.)
(10.1 cm) 33°
Nom.
6" Nom.
(15.2 cm)
4
3
/
8
"
Min.
(11.1 cm)
Combustible
Material Must
Not Overlap
Black Metal
Front Face
2
3
/
4
" Max.
(6.98 cm)
FRAMING
1. Frame the opening for the firebox using
the dimensions shown in Figures 6 and 7
depending on your installation.
2. If firebox is to be installed directly on
carpeting, tile (other than ceramic) or any
combustible material other than wood
flooring, firebox must be installed upon a
metal or wood panel extending full width
and depth of firebox.
Figure 8 - Ember Protectors
3. Set firebox directly in front of opening and
slide unit back until nailing flanges touch
side framing.
4. Check the level of firebox and shim with
sheet metal if necessary.
5. Before securing firebox to prepared fram-
ing, ember protector (provided) must be
placed between hearth extension (not
supplied) and under bottom front edge of
firebox to protect against glowing embers
(see Figure 8 and
Hearth Extensions
on
page 6). If firebox is to be installed on a
raised platform, a Z-type ember protector
(not supplied) must be fabricated to fit
your required platform height (see Figure
7). The ember protector should be made
of sheet metal (28 gauge minimum) to
prevent corrosion.
6. Secure firebox to framing at nailing
flanges located on sides of firebox (see
Figure 9, page 6).
Ember
Protector
(Typ. 2 of 2)
1/2"
(1.2 cm)
Max.