background image

www.fmiproducts.com

55511F

11

Secure 

Termination 

to Outer 

Pipe with 3 

Screws

RTL-8DM

Stainless 

Inner Flue 

Pipe

Apply 

Waterproof 

Caulking

Storm 

Collar

Flashing

Underlap 

Shingles

Figure 25 - Terminations

Overlap 

Shingles (Top 

and Sides of 

Flashing Base)

VenTing inSTALLATion

Continued

CHASE INSTALLATIONS

Instructions  for  chase  installations  are 

included  with  the  chase  style  termination 

chosen. In a multiple chase installation, be 

sure to provide adequate distance between 

terminations to prevent smoke spillage from 

one termination to another. Terminations must 

be separated a minimum of 30" center to cen-

ter and stacked at a minimum vertical height 

difference of 18" (see Figure 26).

Note:

 

If a decorative shroud is to be installed, 

contact the manufacturer for specifications.

FINISHING FIREBOx

Installing Firebox Facing

Any  noncombustible  material  may  be  used 

for facing (glass, tile, brick, etc.) as long as 

proper clearances are adhered to and firebox 

openings are not obstructed in any way (see 

Figure 27).
Use only heat resistant, noncombustible mor-

tar or adhesive when securing facing material 

to  front  of  firebox.  When  placing  facing  at 

upper  edge  of  effective  opening  of  firebox, 

provide “L” shaped piece of metal extending 

full width of opening (see Figure 27).
Secure with sheet metal screws at a distance 

high enough from edge so it doesn't interfere 

with operation of doors. This assures that fac-

ing material will not block openings.

30" Min.

30" Min.

18" 

Min.

Typ.

Figure 26 - Multiple Chase Installation

1" 

Space

Screen

Chase 

Top

1" Non-

com-

bustible 

Spacer

“L” Shaped 

Metal 

Support

Noncombustible 

Facing Material

Noncombustible 

Facing Material

Do Not 

Block 

Opening

Figure 27 - Fireplace Facing (Your 

Fireplace May Vary from Illustration)

Содержание VI368ST

Страница 1: ...andards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard This wood burning firebox complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLI ANCE and is listed...

Страница 2: ...nufacturer s instruc tions with the insert specifically statethisfireboxhasbeentested for use with the insert Thisfireboxisnotintendedtobe usedasasubstituteforafurnace to heat an entire home Use for s...

Страница 3: ...oke or stir the logs while they are burn ing Use only fire logs that have beenevaluatedfortheapplication in fireplace and refer to fire log warnings and caution markings on packaging prior to use WARN...

Страница 4: ...g Typ Figure 3 Firebox Clearances Existing Wall Projected Wall 12 30 4 cm to Perpendicular Wall selecting location To determine the safest and most efficient location for the firebox you must take int...

Страница 5: ...cm Framing 1 Frame the opening for the firebox using the dimensions shown in Figures 6 and 7 depending on your installation 2 If firebox is to be installed directly on carpeting tile other than cerami...

Страница 6: ...Ember Protector Noncombustible Hearth Extension Ember Protector Figure 11 Raised Hearth Extension Figure 9 Nailing Flanges Nailing Flanges Prepared Framing Nails or Screws 1 2 1 27 cm Minimum to Combu...

Страница 7: ...the required clearance between the chimney and the combustible materials When penetrating a floor or ceiling at an angle use firestop spacer number 30FS 8DM see Replacement and Accessory Parts page 14...

Страница 8: ...top Spacer Screws or Staples Min of 8 Existing Ceiling Frame 2 5 1cm Minimum Angled Firestop Ceiling Support Return Elbow 30 FT 9 14m 30 FT 9 14m Figure 16 Elbow Offset Return Elbow 12S 8DM Support Re...

Страница 9: ...of line use support wires to keep chimney secure Support wires may be attached to outer pipe of chimney with screws if screws do not penetrate inner flue pipe Minimum Maximum Chimney Height The minimu...

Страница 10: ...Chimney Pipe Waterproof Caulk Storm Collar Flashing Flashing Installation Determine flashing to be used with roof open ing chart Slide flashing over pipe until base is flat against roof Replace as ma...

Страница 11: ...ecifications finishing firebox Installing Firebox Facing Any noncombustible material may be used for facing glass tile brick etc as long as proper clearances are adhered to and firebox openings are no...

Страница 12: ...e Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole...

Страница 13: ...t be fully open or fully closed position only or a fire hazard may be created see Figure 30 or 31 A firebox equipped with glass doors operates much differently than a firebox with an open front A fire...

Страница 14: ...ngignition Young children should be care fully supervised when they are in the same room as firebox Technical Service You may have further questions about instal lation operation or troubleshooting If...

Страница 15: ...triple wall Double Wall Pipe support assembly 12S 8DM Double Wall 30 elbow Offset 30E 8DM Firestop Spacer FS 8DM for Straight Pipe Econo Top Termination ETL 8DM ETLO 8DM Vent Plaster Collar Vent Hood...

Страница 16: ...11 Rev F 09 09 DG368ST Brushed Brass DC368ST Platinum DBP368ST Black Replacement and Accessory Parts Continued Bi Fold GLASS DOORS 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts...