www.fmiproducts.com
116234-01L
7
A
B
E
F
G
H
D
C
Nailing Tabs
NOTICE: This fireplace is in
-
tended for use as supplemental
heat. Use this fireplace along
with your primary heating sys
-
tem. Do not install this fireplace
as your primary heat source.
If you have a central heating
system, you may run system’s
circulating blower while using
fireplace. This will help circulate
the heat throughout the house.
In the event of a power outage,
you can use this fireplace as a
heat source.
FRAMING AND FINISHING
Figure 4, page 7 shows typical framing of this
fireplace. Figure 5, page 7, shows framing for
corner installation. All minimum clearances
must be met.
For available accessories for this fireplace,
see
Accessories
on page 35. If you are using
a separate combustible mantel piece, refer to
Figure 6, page 7 for proper installation height.
You can install noncombustible mantels at any
height above the fireplace.
Note: Noncombustible mantels may dis-
color!
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
36
1
/
8
"
41
1
/
4
"
21" Horizontal Vent
24
1
/
2
" Vertical Vent
C
B
A
D
E
F
G
Top of Louver
Opening
3
2
1
4
5
6
7
Wall
Figure 5 - Framing Clearances for Corner
Installation
Ref.
Mantel
Depth Ref.
Mantel from
Top of Louver
Opening
1
14"
A
16"
2
12"
B
14"
3
10"
C
12"
4
8"
D
10"
5
6"
E
8"
6
4"
F
6"
7
2"
G
4"
Figure 6 - Clearances for Combustible
Mantels
41"
41
1
/
4
"
35
3
/
4
"
49
5
/
8
"
13
3
/
4
"
68
1
/
2
"
10
3
/
8
"
PRE-INSTALLATION PREPARATION
Continued
Nailing
Tabs
15"