www.fmiproducts.com
116234-01L
24
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
33, page 23).
2. Open propane/LP supply tank valve for
propane/LP fireplace or main gas valve
located on or near gas meter for natural
gas fireplace.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 34, page
23, for propane/LP or Figure 35, page 23,
for natural gas). Apply noncorrosive leak
detection fluid to all joints. Bubbles forming
show a leak. Correct all leaks at once.
5. Light fireplace (see
Operation
, page 28).
Check all other internal joints for leaks.
6. Turn off fireplace (see
To Turn Off Gas to
Appliance
, page 28).
REMOVING/REPLACING GLASS
DOOR
FIREPLACE INSTALLATION
Continued
Removing Louver Panels
Remove top and bottom louver panels by
simultaneously pulling both top end spring
latches towards center of appliance until
they are disengaged from locating holes
(see Figure 36). Repeat for bottom spring
latches and pull louvers outward. To install
or replace items removed, simply reverse
procedures above.
Figure 36 - Removing Louver Panel
Figure 37 - Removing/Replacing Screen
Door Assembly (TCC36 Series)
Removing Screen Door Assembly
(TCC36 Series)
Push screen door assembly in toward the bottom
left and right sides until the magnetic door latch
pops the screen door out. Hold the screen door
assembly at the bottom and swing the door up to
disengage the tabs on the top of the door fromin-
side the slots underneath the upper face.
Magnetic Door Latches
(TCC36 Series)
Door ScreenTabs
(TCC36 Series)
Slots underneath
Upper Face
Replacing Screen Door Assembly
(TCC36 Series)
Push magnetic door latch out to the open
position. Position screen door tabs with slot
openings in upper face frame. Swing door
screen assembly in towards the bottom face,
Press in on the bottom of door screen until
magnetic door latch is pushed in.
Louver
Panel
Spring
Latch
CAUTION: Do not operate
this fireplace with a broken glass
door panel or without the glass
door panel securely in place. For
replacement part information see
Replacement Parts
, page 34.
CAUTION: Wear gloves and
safety glasses while handling or
removing broken glass. Do not
remove if glass is hot. Keep chil
-
dren and pets away from glass.
WARNING: If fireplace has
been running, turn off and un
-
plug fireplace. Let cool before
removing glass door or louvers.