VENTING INSTALLATION
Continued
Figure 13 - Typical Horizontal
Termination Cap Mounting with
Additional Siding Standoff Installed
Siding Standoff
Screws
High Wind
Termination
Apply Mastic
to Outside
Edge of
Standoff
Exterior Wall with Vinyl Siding
11
1
/
2
" x 11
1
/
2
"
Framed Opening
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall
Minimum Pipe
Overlap 1
1
/
4
"
Wall
Firestop
Direct-Vent
Pipe
Horizontal Termination Configurations
Figures 14 through 18 show different con-
figurations and alternatives for venting with
horizontal termination. Each figure includes
a chart with critical minimum and maximum
dimensions which MUST be met.
IMPOR-
TANT
: If using a venting configuration of only
horizontal venting with no vertical run, a 1/4"
rise for every 12" of run toward the termina-
tion is required.
NOTICE: Do not seal termination
cap to vent pipe. Cap must be
removable for vent inspection
and maintenance.
WARNING: Never run vent
downward as this may cause
excessive temperatures which
could cause a fire. Operation of
improperly installed and main
-
tained venting system could
result in serious injury, property
damage or loss of life.
GROUND FLOOR INSTALLATION
Recommended Applications:
• Installation using cabinet surrounds
• Through the wall using round or square
termination (up to 12" adjustable pipe)
• NOT FOR CORNER INSTALLATION
Horizontal
High Wind
Square
Termination
Wall Firestop
45° Elbow
Figure 14 - Horizontal Termination
Configuration for Square or Round
Terminations
45° Elbow
Wall
Firestop
Horizontal
Round
Termination
Exterior
Portion of Wall
Firestop (Round
Termination
Only)
Adjustable
Pipe 12" Max.
Round
Termination
Square Termination
Vertical (V)
Horizontal (H)
32
3
/
4
" min.
17" max.
* If installing this fireplace at altitudes of 4000
feet and above, it is recommended that an
additional vertical height of 6" be added to
the vent system.