saFety

 WARNING: Do not install a 

fireplace insert in this box unless 

the manufacturer's instructions 

with the insert specifically state 

this fireplace has been tested for 

use with this insert.

FOR YOUR SAFETY

•  Do not store or use gasoline 

or any other flammable vapors 

or liquids in the vicinity of this 

or any other appliance. 

•  Due to high temperatures, the 

appliance  should  be  located 

out  of  traffic  and  away  from 

furniture and draperies. 

•  Do not place clothing or other 

flammable materials on or near 

the appliance. 

•  Never  leave  children  unat-

tended when a fire is burning 

in the fireplace. 

 WARNING: Use solid wood 

or processed solid fuel firelogs 

only. When processed wood fuel 

fire logs are used, do not poke or 

stir the logs while they are burn-

ing. Use only fire logs that have 

been evaluated for the application 

in fireplace and refer to fire log 

warnings and caution markings 

on packaging prior to use.

This fireplace is not intended to be 

used as a substitute for a furnace 

to heat an entire home. Use for 

supplemental heat only.

 

WARNING:  Improper 

installation,  adjustment, 

alteration,  service  or 

maintenance  can  cause 

injury,  property  damage 

or loss of life. Refer to this 

manual for assistance or 

additional  information. 

Consult a qualified install-

er or local distributor.

IMPORTANT: Check local codes 

before installing this fireplace.

Before beginning installation of this fireplace, 

read these instructions through completely.
•  This FMI PRODUCTS, LLC fireplace and 

its  components  are  safe  when  installed 

according  to  this  installation  manual. 

Unless  you  use  FMI  PRODUCTS,  LLC 

components,  which  have  been  designed 

and  tested  for  the  fireplace  system,  you 

may cause a fire hazard.

•  The  FMI PRODUCTS,  LLC  warranty  will 

be voided by and FMI PRODUCTS, LLC 

disclaims any responsibility for the following 

actions.
a. Modification  of  the  fireplace,  com

-

ponents,  doors,  air  inlet  system  and 

damper control.

b. Use of any component part not manufac

-

tured or approved by FMI PRODUCTS, 

LLC in combination with a FMI PROD

-

UCTS, LLC fireplace system.

Proper installation is the most important step 

in ensuring safe and continuous operation of 

fireplace. Consult the local building codes as 

to the particular requirements concerned with 

the installation of all factory built fireplaces.

table OF cOntents

Safety ..................................................................

2

Specifications ......................................................

3

Fireplace Installation............................................

4

Venting Installation ..............................................

6

Optional Gas Line Installation.............................

11

Operation and Maintenance Guidelines ............

12

Parts ..................................................................

14

Technical Service...............................................

17

Accessories .......................................................

17

Содержание (V)S36 Series

Страница 1: ...e gas log heater approved toANS Z21 11 2 standard AFMI PRODUCTS LLC hood must be installed when using a vent free log heater see Accessories page 16 This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation t...

Страница 2: ...erty damage or loss of life Refer to this manual for assistance or additional information Consultaqualifiedinstall er or local distributor IMPORTANT Check local codes before installing this fireplace Before beginning installation of this fireplace read these instructions through completely This FMI PRODUCTS LLC fireplace and its components are safe when installed according to this installation man...

Страница 3: ...NOT LESS THAN 12 1 AIRSPACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE SIDEWALL TERMINATION SQUARE CHASE TOP GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 8 125 10 435 14 437 41 25 37 41 35 21 8 32 5 14 25 22 2 5 8 717 1 11 217 2 5 8 125 7 092 8 717 12 5 41 1 0 625 29 21 ...

Страница 4: ...the safest and most efficient location for the fireplace you must take into consideration the following guidelines 1 The location must allow for proper clear ances see Figures 1 and 2 2 Consider a location where the fireplace will not be affected by drafts air condition ing ducts windows or doors 3 A location that avoids the cutting of joists or roof rafters will make installation easier 4 An outs...

Страница 5: ...o prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncom bustible material see Figure 3 Fireplace Installation Continued Figure 3 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension WARNING Hearthextension is to be in...

Страница 6: ...e Check Local Codes Before Installing in a Vented Crawl Space Chimney Pipe The FMI PRODUCTS LLC chimney system consists of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fit ting overlaps must be taken into consideration lineal gain and are given in the lineal gain chart see Figure 6 Lineal gain is...

Страница 7: ...double wall pipe see offset chart and Figure 7 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to rafters or joists see Figure 8 details A and B on page 8 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angle run Maximum of two 6 angle run sections per chimney system see Figure 7 4 All pipe connections between offset and return must be s...

Страница 8: ... of 8 Firestop Spacer Screws or Staples Min of 8 Penetrating roof To maintain a 1 clearance to the pipe on a roof with a pitch a rectangular opening must be cut 1 Determine center point through which pipe will penetrate roof 2 Determine center point of roof Pitch is the distance the roof drops over a given span usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontall...

Страница 9: ... Flashing Cone Underlap Shingles at Bottom Overlap Shingles Top and Sides Only Figure 13 Flashing Installation Storm Collar Installation SC1 or SC2 Place storm collar over pipe and slide down until it is snug against the open edge of the flashing see Figure 14 Use SC1 for all round terminations and SC2 for all terminations with slip sections Apply waterproof caulk around the perimeter of the colla...

Страница 10: ...e 16 Note If a decorative shroud is to be installed contact the manufacturer for specifications 10 foot rule All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the high est point of the roof that is within a horizontal distance of 10 feet see Figure 17 24 Min 24 Min 18 Min Typ...

Страница 11: ...T MAX HEIGHT 14 5 FT MIN HEIGHT OF 22 FT WITH 2 ELBOW SETS MAX HEIGHT OF 50 FT MAX HEIGHT 50 FT ANY SYSTEM 30E 8DM Figure 18 Typical Residential Installations Gas line hook up should be done by your supplier or a qualified service person Note Before you proceed make sure your gas supply is turned off Use only a 1 2 black iron pipe and appropri ate fittings 1 Remove knockout indentation on refrac t...

Страница 12: ...lid Fuel Burning Fireplaces ANS Z21 60 Z21 84 or RG 2 72 and shall also be installed in accor dance with the National Fuel Gas Code ANSI 7223NFPA 54 latest edition WARNING Toavoidtheriskof damagingthefireplacematerials andincreasingtheriskofspread ingafire donotusethefireplace to cook or warm food WARNING If the fireplace hasbeenusedforwoodburning thefireboxandchimneymustbe cleaned of soot creosot...

Страница 13: ...nted or vent free decorative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces ANSI Z21 60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning Fireplaces Draft NO 4 dated August 1993 If you wish to install an unvented vent free gas log set only unvented g...

Страница 14: ... com 111026 01G 14 Parts Wood burning Fireplace MODELS S36 S36H S36R S36RH VS36 1 VS36H 1 vs36r and vs36rh 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 ...

Страница 15: ...nt 1 20 110892 01 Air Deflector 1 21 111327 01 Fireplace Top Insulation 1 22 107775 01 Access Panel 1 23 107854 01 Right Refractory Bracket 1 24 107854 02 Left Refractory Bracket 1 25 111028 01 Grate 1 26 11418 Push On Nut 2 27 110890 01 Stainless Screen 2 28 16405 Collar Insulation 1 29 20023 Chimney Starter Collar 1 30 20027 Refractory Retainer 2 31 106539 02 Grate Retainer 2 32 111073 01 Door S...

Страница 16: ...tured Red Herringbone 1 106659 01 Right Refractory Smooth White Brick 1 108165 01 Right Refractory Smooth White Herringbone 1 11 106660 03 Rear Refractory Textured White Brick 1 108166 03 Rear Refractory Textured White Herringbone 1 106660 02 Rear Refractory Textured Red Brick 1 108166 02 Rear Refractory Textured Red Herringbone 1 106660 01 Rear Refractory Smooth White Brick 1 108166 01 Rear Refra...

Страница 17: ...fmiproducts com Accessories Double Wall Pipe 12 8DM 12 8HT 18 8DM 18 8 HT 24 8DM 24 8HT 36 8DM 36 8HT 48 8DM 48 8HT ROOF FLASHING 0 TO 6 12 PITCH V6F 8DM 6 12 TO 12 12 PITCH V12F 8DM ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM Adjustable Hood Antique Brass Finish GA6053 Black Painted Finish GA6050 Required when installing a vent free gas log in this fireplace Bi Fold Glass Door BDO36 Blac...

Страница 18: ...Round Top Terminations RT 8DM RTL 8DM RounD Top Terminations with Slip Section RTT 8DM RTTL 8DM RounD Top Terminations with LOUVERS RTL 8DM Outside Air Kit for Side Wall Installation AK4 Outside Air Kit for Floor Installation AK4F Square Chase Top Termination ET 8DM ETO 8DM Econo Top Termination with Slip Section ETL 8DM ETLO 8DM ...

Страница 19: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 20: ...111026 01 Rev G 09 09 2701 S Harbor Blvd Santa Ana CA 92704 1 866 328 4537 www fmiproducts com ...

Отзывы: