background image

www.fmiproducts.com

125566-01C

18

4

INSTALLATION

Continued

Figure 23 - Installing Log #4 

Rib

4.  Place front log (#4) on top of left and 

right bottom logs as shown in Figure 23. 

Notches in bottom of log #4 will fit over 

ribs in logs #2 and #3. 

5.  Place top left log (#5) onto rear log (#1) and 

front log (#3). Match round peg on bottom 

of top left log (#5) with round hole in front 

log (#3) and square hole in log #5 with 

square peg on log #1 (see Figure 24).

6.  Place top middle log (#6) onto rear log (#1) 

and front log (#3). Match square peg on 

bottom of log #6 with square hole on log 

#4 and round hole on log #6 with peg on 

log #1 (see Figure 25).

7.  Place top right log (#7) onto top middle 

log #6 and front log (#3) matching peg on 

bottom of top right log #7 with hole on top 

middle log #6 and hole in top right log #7 

with peg on front log (#3) (see Figure 25).

8.  Final Assembly is shown in Figure 26. See 

Figure 27 on page 19 for additional views. 

Figure 24 - Installing Log #5 

Figure 25 - Installing Logs #6 and #7 

6

7

5

Figure 26 - Final Assembly

Содержание TF18NV

Страница 1: ...romaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference VARIABLE REMOTE CONTROL BURNER SYSTEM MODELS TF18NV PV TF2430NV PV TF MODELS ...

Страница 2: ... unvented gas fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manual This appliance may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use ...

Страница 3: ...teschemicals known to the state of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace can cause serious injury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning DANGER Carbonmonoxide poisoning may lead...

Страница 4: ...ent the creation of soot follow the instructions in Cleaning and Maintenance page 31 9 Before using furniture polish wax carpet cleaner or similar products turn heater off If heated thevaporsfromtheseproductsmay create a white powder residue within burner box or on adjacent walls and furniture 10 This heater needs fresh outside air ven tilation to run properly This heater has an Oxygen Depletion S...

Страница 5: ...l local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSI Z223 1 NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 CAUTION Donotremovethe data plates from the grate as sembly The data plates contain important warranty and safety infor...

Страница 6: ...Fresh air must enter your home All fuel burning ap pliances need fresh air for proper combustion and ventilation Exhaust fans fireplaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide adequate fresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING ADEQUATE VENTILATION The following are excerpts from...

Страница 7: ...Btu Hr the space can support _________ volume of space x 20 Maxi mum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace ___________ Btu Hr Gas water heater ___________ Btu Hr Gas furnace ___________ Btu Hr Vented gas heater ___________ Btu Hr Gas fireplace ...

Страница 8: ...Crawl Space To Attic WARNING Iftheareainwhich theheatermaybeoperateddoes notmeettherequiredvolumefor indoorcombustionair combus tion and ventilation air shall be provided by one of the methods described in the National Fuel GasCode ANSIZ223 1 NFPA54 theInternationalFuelGasCode or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining...

Страница 9: ...heater WARNING This appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted NOTICE Thisheater isintended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a centralheatingsystem youmay run system s circula...

Страница 10: ...ce hood accessory 24 and 30 Models Only See Figure 5 for minimum clearances LOG SIZING REQUIREMENTS Log Size Minimum Firebox Size Height Depth Front Width Rear Width 18 20 14 28 20 24 20 14 32 22 30 20 14 40 30 Carefully follow the instructions below This will ensure safe installation into a masonry UL127 listed manufactured fireplace or listed vent free firebox Minimum Clearances For Side Combust...

Страница 11: ...es When Using Hood Minimum Non Combustible Material Minimum Non Combustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12 8 A 18 14 20 17 22 19 24 20 All minimum distances are in inches Log Set 24 30 Models 18 Model 2 1 2 6 8 10 Mantel Shelf If Using Mantel You must have noncombustible material s above the fireplace opening Noncombustible ma...

Страница 12: ...reads of the 1 2 NPT side of gas fitting elbow provided and connect to inlet side of gas control Remove gas fitting from flexible gas hose provided before connecting to elbow see Figure 10 14 Min Combustible Material Noncombustible Material Figure 8 Minimum Fireplace Clearances If Installed at Floor Level Hearth 5 Min Combustible Material Figure 9 Minimum Fireplace Clearances Above Combustible Flo...

Страница 13: ...Thread inlet connection to the pressure regulator WARNING A qualified ser vicepersonmustconnectheater to gas supply Follow all local codes CAUTION Never connect propane LP fireplace directly to the propane LP supply This heaterrequiresanexternalregu lator not supplied Install the external regulator between the heater and propane LP supply WARNING Never connect natural gas fireplace to private non ...

Страница 14: ...ial requirements for locating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male NPT threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves WARNING Use pipe joint sealant that is resistant to liquid petroleum LP gas Propane LP Supply Tank External Regulator with Vent Pointing Down Figure 12 External Reg...

Страница 15: ...ze supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supp...

Страница 16: ...R WARNING Make sure your selector switch is in OFF posi tion before installing or chang ing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control uses 3 AAA batteries not included To install batteries 1 Remove battery housing cover from back of hand held remote see Figure 17 2 Install or replace batteries 3 Replace battery housing cover When batteries...

Страница 17: ...ames contact any log If so reposition logs according to log installation instructions in this manual Flames contacting logs will create soot LTF 18 24 30 SO SERIES LOG PLACEMENT It is very important to install these logs exactly as instructed Do not modify logs Only use logs supplied with heater or as identified for use with the heater as shown in Figure 20 Note Each log is marked with a part numb...

Страница 18: ...ith square peg on log 1 see Figure 24 6 Place top middle log 6 onto rear log 1 and front log 3 Match square peg on bottom of log 6 with square hole on log 4 and round hole on log 6 with peg on log 1 see Figure 25 7 Place top right log 7 onto top middle log 6 and front log 3 matching peg on bottom of top right log 7 with hole on top middle log 6 and hole in top right log 7 with peg on front log 3 s...

Страница 19: ...ges of plate as shown in Figure 29 Figure 27 Correct LTF 18 24 30 SO EMC Log Placement 18 Models 24 Models 30 Models INSTALLATION Continued 1 Figure 28 Installing Log 1 Figure 29 Installing Log 2 U Burner Base as sembly 2 3 Place the front left log 3 onto the base assembly between the middle log and the grate The back of the front left log will rest against the front of the middle log The notch in...

Страница 20: ...rectangular projection on top of tyhe middle log with the rectangular hole on the bottom of the left top front log The left top front log will rest on the flat part of the left top back log See Figure 33 7 Place the right crossover log 7 on top of the middle log and rear log as shown in Figure 34 page 21 Match the round peg on the top of the rear log with the round hole on the bottom of the right ...

Страница 21: ...d The 24 indicates this log belongs to a 24 inch log set See page 42 for reference numbers detail 1 Place the rear log 1 on base assembly as shown in Figure 37 Log will fit over right end of burner and rest in middle of U burner 1 Figure 37 Installing Log 1 U Burner Base assembly 1 Place the middle log 2 in front of the U burner and against the edges of the plate as shown in Figure 38 page 22 2 Pl...

Страница 22: ...le on the bot tom of the left back top log 5 Match the metal pin on the top of the rear log 1 with the round hole in the bottom of the left back top log 5 See Figure 41 5 Place the left top forked log 6 on the top of the middle log 2 Match the rectangular projection on top of the middle log 2 with the rectangular hole on the bottom of the left top forked log 6 Match the metal pin on teh top of the...

Страница 23: ...id log 8 as shown in Figure 45 Match the round peg on the top of the right rear chunk log 7 with the round hole on the bottom of the top right log 9 and square peg on the top of the front right mid log 8 with the square hole on the bottom of the top right log 9 8 9 Round Peg Metal Pin Round Peg Square Peg Square Peg 9 Place the right rear top log 10 on top of the right rear chunk log 7 as shown in...

Страница 24: ... instructed Do not modify logs Only use logs supplied with heater or as identified for use with the heater as shown 1 Place bottom ember log on base as sembly as shown in Figure 49 The log should fit over the left side of the burner and rest in the middle of the U burner 2 Place the rear log on the base assembly as shown in Figure 50 The rear log has grooves in the bottom which will allow the log ...

Страница 25: ... with the projection on the right front log 5 Place the right crossover log onto the rear log and the right front log as shown in Figure 53 The right crossover log has notches in the bottom that will line up with the projections on the rear log and the right front log 6 Place the left crossover log onto the rear log and the left front log as shown in Figure 54 The left crossover log has notches in...

Страница 26: ...bers give a bright glow appearing as hot coals Should embers need replacing see Parts page 38 Platinum Bright Ember placement Add embers to front flat burner Gently remove embers from bag Separate pieces of ember material and place on surface of flat burner just behind horizontal ports as shown in Figure 55 Rock Wool placement Place rock wool material on front flat burner in areas away from ports ...

Страница 27: ...follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the ...

Страница 28: ...igure 58 Remote Selector Switch in ON Position Figure 59 Pilot Natural Propane LP Pilot Burner Ignitor Electrode TO TURN OFF GAS TO APPLIANCE 1 Turn control knob clockwise to the OFF position 2 Set selector switch in the OFF position 3 Close equipment shutoff valve see Figure 14 page 15 MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 6 under Lighting Instructions page 27 2 Depress control knob ...

Страница 29: ...e temperature in either Fahrenheit or Celsius With remote control off press THERMOSTAT button and MODE button at the same time This will toggle the display from F to C Figure 61 Remote Control Display Fahrenheit to Celsius Figure 62 Hand Held Remote Control ON OFF MODE UP DOWN Arrows THERMOSTAT LCD Display OPERATING REMOTE CONTROL WARNING Fireplace can turn on suddenly Keep away from burner After ...

Страница 30: ...emperature bulb graphic on display see Figure 64 Use UP DOWN arrow button to set desired room temperature Control system will cycle fireplace on or off to maintain selected temperature To activate this function press THERMOSTAT button until the word SMART appears to the right of temperature bulb graphic on display Use UP DOWN arrow button to set desired room temperature The control system will cyc...

Страница 31: ...nd property damage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air in let holes prior to each heating season Blocked air holes will create soot We recommend that you clean the unit every three months during operatio...

Страница 32: ... inlet hole You may blow through a drinking straw if compressed air is not available CLEANING AND MAINTENANCE Continued LOGS If you remove logs for cleaning refer to Installing Logs Embers and Lava Rock page 17 to properly replace logs Replace log s if broken or chipped dime sized or larger MAIN BURNER Periodically inspect all burner flame holes with heater running All slotted burner flame holes s...

Страница 33: ... 14 W C Min 11 W C TF18NV Rating Variable 21 000 30 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C TF2430NV Rating Variable 28 000 39 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C WIRING DIAGRAM Black Connectors Receiver To Thermopile Wh...

Страница 34: ... gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Overlap ember material 1 4 see page 26 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace ignitor 5 Replace pilot assembly 6 Replace pilot assembly 7 Install new alkaline bat t...

Страница 35: ... knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 31 or replace ODS pilot assembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve 1 Contact loca...

Страница 36: ...ners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 11 4 Clean burners see Clean ing and Maintenance page 31 or replace burner orifice s 1 Turn heater off when us ing furniture polish wax carpet cleaners or similar products 1 Refer to Air for Combustion and Ventilation require ments page...

Страница 37: ...ged 1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Hand held remote control is too close to heater REMEDY 1 Open window to venti late room Stop using odor causing products while heater is running 2 Refill supply tank propane LP only 3 Locate and correct all ...

Страница 38: ...2 4 5 8 9 10 20 18 19 17 13a 12 PARTS AVAILABLE NOT SHOWN 100563 01 Warning Plate 1 103877 01 Lighting Instruction Plate 1 100639 12 Caution Decal 1 101137 02 Hardware Kit 1 GA6060 Lava Rock 1 120466 01 Flextube with Fitting TF models only 1 125071 01 Rockwool Embers 1 125070 01 Platinum Bright Embers Kit 1 099998 01 Fan Switch 1 103284 11 Wire Harness 1 ...

Страница 39: ...40 Orifice 0 0635 1 099056 41 Orifice 0 0335 1 099056 47 Orifice 0 066 1 099056 46 Orifice 0 0689 1 14 125019 01 Ignitor Bracket 1 15 111435 01 Electronic Ignitor 1 16 098271 12 Ignitor Cable 1 17 112829 02 Air Shutter 1 18 119795 01 Gasket 1 19 119321 01 Venturi Tube 1 20 097384 01 ODS Nut 2 21 116559 04 Natural Gas Air Shutter 1 116559 03 Propane LP Gas Air Shutter 1 22 124933 01 Holder Orifice ...

Страница 40: ...ht Log 3 1 4 125052 05 125052 06 125052 07 Front Log 4 1 5 120954 05 125052 09 125052 09 Top Left Log 5 1 6 120954 06 120954 06 120954 06 Top Middle Log 6 1 7 120954 07 120954 07 120954 07 Top Right Log 7 1 8 121079 01 121079 01 121079 01 Switch Log 1 PARTS LOG SETS FOR MODELS LTF18 SO LTF14 SO LTF30 SO This list contains replaceable parts used in your heater When ordering parts follow the instruc...

Страница 41: ...r Crossover Log 8 1 9 125538 01 125538 01 125538 01 Switch Log 1 PARTS LOG SETS FOR MODELS LTF18 MO LTF24 MO LTF30 MO This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 44 of this manual 2 6 3 4 9 1 7 8 5 Each log includes reference numbers formed in the bottom or back of the log The circled number indicates t...

Страница 42: ...65 01 Middle Log 2 1 3 125335 03 125336 03 125337 03 Front Left Log 3 1 4 125563 02 125564 02 125565 02 Front Right Log 4 1 5 125563 03 125564 03 125564 03 Left Top Back Log 5 1 6 125563 04 125564 04 125565 04 Left Top Forked Log 6 1 7 125563 05 125564 05 125565 05 Right Rear Chunk Log 7 1 8 125563 06 125564 06 125564 06 Front Right Middle Log 8 1 9 125563 07 125564 07 125565 07 Top RIght Log 9 1 ...

Страница 43: ...manual KEY NO PART NUMBERS DESCRIPTION QTY LTF18 RS LTF24 RS LTF30 RS 1 125867 03 125867 09 125867 09 Bottom Ember Log 1 1 2 125867 04 125867 10 125867 10 Rear Log 2 1 3 125867 02 125867 08 125867 14 Right Front Log 3 1 4 125867 01 125867 07 125867 13 Left Front Log 4 1 5 125867 06 125867 12 125867 12 Right Crossover Log 5 1 6 125867 05 125867 11 125867 11 Left Crossover Log 6 1 7 121079 01 121079...

Страница 44: ...LACEMENT PARTS Note Use only original This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 When calling have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you ...

Страница 45: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 46: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 47: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 48: ...his product and or FMI PRODUCTS LLC who will provide original factory Failure to use original factory voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded from this warranty are products or ...

Отзывы: