8
105383
UV32C and RUV32 UNVENTED 32" FIREBOX
FIREPLACE MANUFACTURERS INC.
Built-In Installation of Blower
Accessory
1.
Install blower assembly per instruction
sheet included.
2.
Before replacing bottom of firebox,
remove screw holding duplex outlet to
the support bracket in the bottom of
firebox. Remove duplex outlet.
3.
Clamp electrical cable into firebox
through smallest hole in outer casing
using strain relief provided.
4.
Route wires from electrical box through
hole in side of heater and hole in sup-
port bracket (see Figure 9).
5.
Connect wires from the electrical box
to duplex outlet. Match wire colors to
those indicated on duplex outlet. Be
sure to connect ground wire.
6.
Replace duplex outlet with screw.
7.
Plug blower power cord into duplex
outlet.
8.
Replace bottom of firebox.
NOTICE: A qualified electrician
must connect electrical wiring to
duplex outlet for built-in installa-
tion. Follow all local codes. In
absence of local codes follow
The
National Electrical Code ANS/
NFPA 70.
Figure 9 - Routing Blower Accessory
Power Cord for Built-In Installation
INSTALLING BLOWER
ACCESSORY
(Model UV32C only)
You may install blower accessory FA3700
with a cabinet mantel installation or with
built-in installation (page 10) with model
UV32C only. To install blower accessory,
see instruction sheet included with the kit.
Cabinet Mantel Installation of
Blower Accessory
1.
Install blower assembly per instruction
sheet included in blower accessory kit.
2.
Before replacing bottom of firebox,
route blower power cord through hole
in support bracket in bottom of firebox
and through hole in side of firebox to
grounded, three-prong 120 volt electri-
cal outlet (see Figure 8). Plug electri-
cal cord into outlet.
3.
Replace bottom of firebox.
Figure 8 - Routing Blower Accessory
Power Cord for Cabinet Mantel Installation
Electrical
Outlet
Side
Opening
Support Bracket
Opening
Blower Power Cord
Blower
INSTALLATION
Continued
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Mantel Shelf
13" 16"
19"
21"
18.5" 20"
21" 22"
For RUV32 Series
noncirculating
smooth face models
2
1
/2
"
6"
8"
10"
For UV32C Series
circulating louvered
models only
Note
:
All vertical measurements
are from top of fireplace
opening to bottom of mantel
shelf. All measurements
are in inches.
Facing material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments.
Figure 7 - Minimum Mantel Clearances for Built-In Installation
Cables From
Electrical
Source
Duplex
Outlet
Screw
Blower Power Cord
Blower
Support
bracket