background image

Save this manual for future reference.

WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the fire

department.

— Installation and service must be performed by a

qualified installer, service agency, or the gas supplier.

WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or addi-
tional information consult a quali-
fied installer, service agency, or
the gas supplier.

WARNING: For use only with
decorative type unvented room
heaters. Do not build a wood fire.

This firebox may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e. Installation of this product is
permitted after the manufactured (mobile) home is sited).

UV32C (shown)

Circulating

Louvered and

RUV32 Non-

circulating

Smooth Face

Models

OWNER’S OPERATION AND INSTALLATION MANUAL

®

This firebox has been tested
and approved by I.A.S. under
their REQ. 2-97 for use with any
ANS Z21.11.2 approved gas
logs.

UNVENTED (VENT-FREE)

32" UNIVERSAL FIREBOX

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

Содержание RUV32

Страница 1: ...tion adjustment alteration ser vice or maintenance can cause injury or property damage Re fer to this manual for correct installation and operational pro cedures For assistance or addi tionalinformati...

Страница 2: ...r for Com bustion and Ventilation pages 4 through 6 9 Do not run firebox where flammable liquids or vapors are used or stored under dusty conditions 10 Do not use this firebox to cook food or burn pap...

Страница 3: ...8 19 3 8 Figure 1 Firebox Front View Built in Nailing Flanges Standoffs Model RUV32 only Louvers Model UV32C only 12 1 2 2 3 4 1 1 2 9 3 4 4 5 8 2 1 2 6 32 3 16 33 11 16 Standoffs Model RUV32 only El...

Страница 4: ...irebox will be located Al low for wall and ceiling clearances see Installation Clearances page 7 2 Everything needed to complete instal lation 3 These models CANNOT be installed in a bedroom or bathro...

Страница 5: ...e outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________________Btu Hr maximum the space can support ________________...

Страница 6: ...ng unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 5 Ventilation Air from Outdoors Ventilation Air From Outdoors Provide extra fresh air...

Страница 7: ...ional vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the firebox in high traffic areas in windy or drafty areas Figure6 Min...

Страница 8: ...binet mantel installation or with built in installation page 10 with model UV32C only To install blower accessory see instruction sheet included with the kit Cabinet Mantel Installation of Blower Acce...

Страница 9: ...pick up log base assembly by burners This could damage burners Only handle base by grates INSTALLING FIREPLACE SCREEN 1 Insert each rod through nine rings lo cated at top of screen 2 Insert first rod...

Страница 10: ...installation includes an approved flexible gas line if allowed by local codes after the manual shutoff valve The flexible gas line must be the last item installed on the gas piping See Connecting to...

Страница 11: ...iginal replacement part s call Fireplace Manufacturers Incorporated s Technical Service Depart ment at 1 888 427 8322 When calling Fireplace Manufacturers Inc have ready your name your address model n...

Страница 12: ...12 105383 UV32C and RUV32 UNVENTED 32 FIREBOX FIREPLACE MANUFACTURERS INC ILLUSTRATED PARTS BREAKDOWN RUV32 5 14 16 16 16 13 15 17 17 17 16 6 1 16 7 16 8 20 12 18 10 19 9 4 2 3 2 16 11 18 18...

Страница 13: ...1 4 101932 02 Side Firebrick 2 5 103207 01 Outer Casing 1 6 103208 01 Outer Shell Base 1 7 103245 01 Firebox Wrapper 1 8 103297 01 Assembly Screen 2 9 103217 01CK Hood 1 10 103773 02CK Front Assembly...

Страница 14: ...14 105383 UV32C and RUV32 UNVENTED 32 FIREBOX FIREPLACE MANUFACTURERS INC ILLUSTRATED PARTS BREAKDOWN UV32C 5 16 16 15 16 17 22 6 1 16 7 16 14 21 13 8 20 12 18 10 19 9 4 2 3 2 16 11 18 18...

Страница 15: ...3207 01 Outer Casing 1 6 103208 01 Outer Shell Base 1 7 103245 01 Firebox Wrapper 1 8 103297 01 Assembly Screen 2 9 103217 01CK Hood 1 10 103773 01CK Front Assembly 1 11 103250 01CK Firebox Bottom 1 1...

Страница 16: ...be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of no...