background image

56131

Rev. L

04/13

WARRANTY

KEEP THIS WARRANTY

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products

Standard Warranty:

 FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free 

from defects in material and workmanship for a period of two (2) year from the date of first purchase from 

an authorized dealer provided the product has been installed, maintained and operated in accordance with 

FMI PRODUCTS, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 

the date of first purchase.

Factory Reconditioned Products

Limited Warranty:

 FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof 

to be free from defects in material and workmanship for 30 days from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with 

FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 

this warranty the bill of sale or other proof of purchase must be presented.

This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 

and only when installed by a qualified installer in accordance with all local codes and instructions furnished 

with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and 

an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider 

approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this 

product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use 

original factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 

repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 

responsibility of the owner.

All warranty will be voided if this product is used with a thermostat.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 

improper installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express war

-

ranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of 

any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to 

two (2) year on new products and 30 days on factory reconditioned products from the date of first purchase. 

FMI PRODUCTS, LLC makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC 

shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, 

or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 

incidental or consequential damages, so the above limitation or exclusion may not apply to you. 

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

For information about this warranty contact:

Model (

located on product or identification tag)

 _____________________________

Serial No. (located on product or identification tag)

 __________________________

Date Purchased  __________________________

Keep receipt for warranty verification.

2701 S. Harbor Blvd.

Santa Ana, CA 92704

1-866-328-4537

www.fmiproducts.com

Содержание Peninsula VDVF36

Страница 1: ...ch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Insta...

Страница 2: ...ces State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts WARNING Thisproductcon tainsand orgenerateschemicals known to the Stat...

Страница 3: ...and proper operation of this fireplace WARNING Any change to this fireplace or it s controls can be dangerous Do not modify this fireplace under any circum stances Any parts removed for servicingmust...

Страница 4: ...ic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects on the appliance Do not use this fireplace to cook food or b...

Страница 5: ...y tank s inside any structure Locate propane LP supply tank s outdoors To prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 2 If you smell gas shut off gas sup...

Страница 6: ...2 5 8 34 3 4 3 BACK VIEW TOP VIEW Left Side Right Side Front Back 24 1115 16 101 2 11 2 11 2 101 2 FRONT VIEW 30 Opening 24 25 RIGHT SIDE 22 5 8 43 1 8 32 Opening 1 7 8 1 7 8 BACK VIEW 39 3 4 26 3 8 3...

Страница 7: ...REMENTS Determine the safest and most efficient loca tion for your FMI PRODUCTS LLC direct vent fireplace Make sure that rafters and wall studs are not in the way of the venting system Choose a locati...

Страница 8: ...Figure 5 Minimum Clearances See Thru Shown Combustible Material Drywall 2 x 4 Stud Minimum 1 Clearance from Side Only for See Thru FRAMING Once final location has been determined observing clearances...

Страница 9: ...n 10 Square Min Figure 12 Rough Opening for Installing Exterior Vent Terminal Vertical Height Depends on Installation 26 3 8 Horizontal Length Depends on Installation 90o Elbow 45o Elbow Figure 13 Ven...

Страница 10: ...1 also known as NFPA 54 These models are approved for use with FMI PRODUCTS LLC 5 8 Series rigid type direct vent pipe as supplied by FMI PROD UCTS LLC or with approved types of flexible vent pipe no...

Страница 11: ...US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L...

Страница 12: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP...

Страница 13: ...uired You may use a chase with a vent termination with exposed pipe on exterior of house See Installing Vent System in a Chase page 14 Your FMI PRODUCTS LLC direct vent fireplace has been tested for a...

Страница 14: ...stallation for Horizontal Termination The maximum vertical run is 30 see Installation for Vertical Termination page 17 Installing Vent System in a Chase A chase is a vertical box like structure built...

Страница 15: ...re terminals are available one for rigid pipe applications and one for flex pipe ap plications A round vent termination with a slip fit connection is also provided for rigid pipe applications to be us...

Страница 16: ...ate number of spring spacers at ends and closest bend to termination to prevent kinks or collapsing on the fire Do not use screws with flex pipe Vent system must be code inspected and released before...

Страница 17: ...Vent H Min Height from Roof Figure 25 Vertical Vent Termination Clearance ROOF PITCH H Min Flat to 6 12 1 0 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 1...

Страница 18: ...ctions you must support vent pipe every 3 feet Use wall straps for this purpose see Figure 24 page 17 When ever possible use 45 elbows instead of 90 elbows The 45 elbow offers less restriction to the...

Страница 19: ...to roofline 2 minimum below finished ceiling Cathedral ceiling support box Level Cathedral Ceiling Installation 1 Remove shingles or other roof covering as necessary to cut rectangular hole for sup po...

Страница 20: ...Configuration With No Horizontal Run Vertical Venting V 40 max Figure 33 Recommended 12 Extension for High Altitude Installation 45 Starter Elbow Note Install restrictor into inner collar of fireplac...

Страница 21: ...58 Basement Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Square Termination 4 Pipe 90 Elbow 20 Screws VKS 58 Snorkel Vent Kit Galvanized Includes 45 Elbow 7 12 A...

Страница 22: ...e and is located on the lower right side of appliance see Figure 37 page 23 The variable speed controller is mounted on a magnetic base and may be positioned anywhere within an accessible distance beh...

Страница 23: ...ver SKYTECH Model Optional Fan Kit Plug Receiver Pull to Remove Insulation Tab Battery Cover 12 Volt Battery Figure 40 Installing Battery in Hand Held Remote Control Unit SKYTECH Figure 37 Connecting...

Страница 24: ...rom the gas supply piping system by closing its individual equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa...

Страница 25: ...T S T E A a n d V DVF36TPNPEA TSTPEA models see Fig ure 44 O F F P I L O T ON L O HI P ILOT E A 16AI 7 TPTH TP TH Figure 43 Millivolt Control Valve Pilot Adjustment Cap ON OFF Knob Outlet Pressure Inl...

Страница 26: ...top of logs B a shown in Figure 50 11 When finished installing logs close glass door Make certain safety door switch is fully pressed by door frame before secur ing four 4 spring loaded latches 12 Re...

Страница 27: ...proper clearances are observed see Clearances page 7 IMPORTANT Louvered openings must not be obstructed and upper and lower panels must remain removable for FIREPLACE INSTALLATION Continued servicing...

Страница 28: ...f burner and pilot as sembly In cleaning take care not to alter pilot or burner location Be sure appliance is cool before each maintenance session CAUTION Theapplianceand logs can get very hot Handle...

Страница 29: ...move glass from frame Use any glass cleaner to clean glass Do not use abrasive clean ers as this may damage glass 3 If replacement is necessary entire assem bly frame and glass must be replaced If gla...

Страница 30: ...S TO APPLIANCE 1 Turn off wall switch 2 Turn off all electric power to appliance if service is to be performed 3 Remove control access panel 4 Push in gas control knob slightly and turn clockwise to O...

Страница 31: ...ian or gas supplier OPERATION Continued SPECIFICATIONS V DVF36TPNA A HA V DVF36TSTA A HA Input Rating 35 000 23 300 Btu Hr Fuel Natural Gas Manifold Pressure 3 5 W C Minimum Supply Pressure 4 5 W C Ma...

Страница 32: ...technician replace pilot line 7 Replace control valve see Replacement Parts and Ac cessories page 35 8 Tighten thermocouple or replace 1 Check wiring connection Refer to Wiring Diagrams page 34 1 Chec...

Страница 33: ...hoses Con sult pipe fitter or plumber 2 Repeat lighting procedure several times to purge air from lines If unit will still not light contact a qualified ser vice and repair technician 3 Remove debris...

Страница 34: ...nd valve are set to ON position Frequent main burner outage WIRING DIAGRAMS GND J BOX RECEPTACLE GRN BLK WHT GRN NOT SUPPLIED INCOMING 120V AC FUSE BOX OR BREAKER FIELD WIRE WHT BLK CONNECTORS Variabl...

Страница 35: ...at 1 866 328 4537 When calling please have your model and serial numbers of your fireplace ready You can also visit our web site at www fmiproducts com REPLACEMENT PARTS Contact authorized dealers of...

Страница 36: ...ivolt Wires Wall Switch and Cover Plate BLOWER KIT DVFFBK For all models Increases air circulation to maximize heat distribution PARTS AND ACCESSORIES ON OFF MANUAL GAS CONTROL VALVE Natural 14389 Pro...

Страница 37: ...ront Bottom 25854 Left Right Bottom 25856 Rear 25855 Front Bottom Left Right Bottom Rear For Peninsula and See Thru PIEZO IGNITOR 097159 04 GRATE 11184 PARTS AND ACCESSORIES Continued BURNER ASSEMBLY...

Страница 38: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Страница 39: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Страница 40: ...will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs asso...

Отзывы: