OUTLAND FIREBOWL

®

 OWNER & SAFETY MANUAL 

Owner & Safety Manual

3

2

All LP cylinders to be used with this appliance must be: 
a.   Constructed and marked in accordance with the 

specifications for LP-gas cylinders Standard, CAN/CSA 
B339, Cylinders, Spheres and Tubes for the Transportation of 
Dangerous Goods.
 

b.  Provided with a listed overfilling prevention device.
c.  

Provided with a cylinder connection device compatible with 
the connection for outdoor cooking appliances. 

d.   The LP gas cylinder used for this appliance must not have a 

capacity larger than 20lb. (9 kg).

e.   Approximately 18” (46 cm) high & 12” (30 cm) diameter.
f.   The use of an approved LP gas cylinder stabilizer, such as the 

one included, must be used when using this appliance in order 
to prevent the LP gas cylinder from tipping over.

ENCLOSURES FOR SELF-CONTAINED  

LP GAS SYSTEMS:

An enclosure for an LP-gas cylinder shall be ventilated by 
openings at both the upper and lower levels of the enclosure. This 
shall be accompanied by one of the following:
a.   One side of the enclosure shall be completely open; or
b.   For an enclosure having four sides, a top, and a bottom:

At least two ventilation openings (see Part IV, Definitions) shall 
be provided in the sidewalls of the enclosure, located within 5 
in (217 mm) of the top of the enclosure, equally sized, spaced 
at a minimum of 90 degrees (1.57 rad), and unobstructed. The 
opening(s) shall have a total free area of not less than 1 in

2

 per lb 

(14.2 cm

2

 per kg) of stored fuel capacity.

Ventilation opening(s) shall be provided at floor level of the 
enclosure and shall have total free area of not less than 1/2 in

2

 per 

lb (7.1 cm

2

 per kg) of stored fuel capacity. If ventilation openings 

at floor level area are in the side wall, there shall be at least two 
openings. The bottom of the openings shall be 1 in (25.4 mm) or 
less from the floor level and the upper edge no more than 5 in (127 
mm) above the floor level. The openings shall be equally sized, 
spaced at a minimum of 90 degrees (1.57 rad), and unobstructed.

Every opening shall have minimum dimensions so as 
to permit the entrance of a 1/8 in (3.2 mm) diameter rod.
Ventilation openings in sidewalls shall not communicate directly 
with other enclosures of the appliance.

 

Heat Sensitive

Hand Wheel

Regulator

Cylinder 

Shut Off Valve

Check Valve

Nipple with

Flow Limiting Device

CONNECTION:

1.  

Be sure the cylinder valve and appliance valves  
are “off”.

2.  Place full LP gas cylinder on tank stabilizer ring.
3.   Center the nipple in the cylinder valve and hold in place. 
4.   Using the other hand, turn the hand wheel clockwise until 

there is a positive stop. Do not use tools. 

5.   Hand tighten only. When making the connection,  

hold the regulator in a straight line with the cylinder valve, so 
as not to cross thread the connection.

6.   Leak test the connection. See section named “LEAK TEST”.

 

 WARNING:

Ensure that the LP gas cylinder is kept at a minimum 
distance of three feet (36 inches) away from the appliance.

LP Cylinder

Appliance

Tank Ring

Minimum 36”

LEAK TEST: Apply the solution to the LP gas delivery system at points.  

Valve coupling regulator & Cylinder Coupling. 

LEAK TEST: Apply the solution to the LP gas 

delivery system at points: 

1. Firebowl Valve Coupling 

2. Gas Hose Regulator 

3. Cylinder Valve Coupling

Содержание OUTLAND FIREBOWL FMPPC2-2

Страница 1: ...D 823 000 V0 Owner s Manual FMI BRANDS INC 309 19133 26th Avenue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 Model number FMPPC2 2 Series number 823 ...

Страница 2: ...nce 2 Extinguish any open flame 3 If odour continues keep away from the appliance and immediately call your gas supplier or fire department WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For outdoor use only ...

Страница 3: ...r stabilizer such as the stabilizer ring included must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information provided on the last page of this Manual Please ensure that all adults and children which use or are near a unit in use are aware of the hazard of high surface temperatures present on the unit during...

Страница 4: ...vided at floor level of the enclosure and shall have total free area of not less than 1 2 in2 per lb 7 1 cm2 per kg of stored fuel capacity If ventilation openings at floor level area are in the side wall there shall be at least two openings The bottom of the openings shall be 1 in 25 4 mm or less from the floor level and the upper edge no more than 5 in 127 mm above the floor level The openings s...

Страница 5: ...ontact FMI Brands Inc should you require a replacement hose Inspect burner prior to each use Burner must be replaced prior to the appliance being put into operation if there is evidence of damage Replacement burners are available from FMI Brands Inc Should any part of this appliance including the burner become soiled or dirty wipe lightly with a damp cloth Do not use flammable or corrosive cleanin...

Страница 6: ...is pictured here Never handle rocks which have not been allowed to cool from exposure to flame Never attempt to rearrange rocks while unit is ignited Note Rocks are not to exceed a maximum weight of 2 kgs or 4 4 lbs SECTION 2 IGNITION STEP 1 Ensure that unit valve dial is in the OFF position by pushing and turning clockwise until the dial stops STEP 2 Securely attach regulator large end of hose to...

Страница 7: ...lame is present during operation by visually inspecting the burner to ensure the presence of flames STEP 6 Using a lighter or match ignite lighter and hold flame slightly above the burner then open the valve on the appliance slowly by turning counter clockwise until the unit ignites STEP 7 Once the unit is burning normally set the dial to desired flame height WARNING Ensure that no parts of your b...

Страница 8: ...opane cylinder is between 7 and 11 hours depending on where the flame height is set FMI Brands Inc recommends that you ignite this unit only when safely placed on a non combustible surface as pictured above This is NOT a toy Children should be supervised at all times when using this unit without exception Do not place any objects other than supplied rocks inside the burner component of the Firebow...

Отзывы: