background image

  1-888-514-1663 |  

WWW.OUTLANDFIREBOWL.COM

4

LEAK TEST:

1.  

DO NOT USE OR PERMIT SOURCES OF IGNITION  
IN THE AREA WHILE DOING THE LEAK TEST. 
THIS INCLUDES SMOKING.

2.  

Leak testing should be done once per year or whenever the 
LP gas cylinder or any other gas system part is taken apart, 
serviced or replaced, whichever is more frequent.

3.   Ensure all gas system coupling joints are tight  

and properly attached.

4.   Prepare a leak testing solution of half liquid detergent  

and half water.

5.   Apply the solution to the LP gas delivery system at points as 

shown in illustration indicated on page 3.

6.  

The leak(s) must be stopped by tightening the loose joints, 
if possible, or by replacing the faulty parts(s) with the part(s) 
recommended by the appliance manufacturer.

THE APPLIANCE IS NOT TO BE USED UNTIL  

ANY LEAK IS CORRECTED.

A gas appliance repairman or LP gas dealer should be called if 
attempts to stop the leak(s) are unsuccessful and, in such case, the 
LP gas supply must be shut off at the cylinder valve or the cylinder 
must be removed from the appliance until the leak(s) is corrected.

Inspect hose prior to each use of the unit. The hose assembly 
must be replaced prior to the appliance being put into operation 
if there is evidence of excessive abrasion or wear, or if the hose 
is damaged. Contact FMI Brands Inc. should you require a 
replacement hose.

Inspect burner prior to each use. Burner must be replaced prior 
to the appliance being put into operation if there is evidence of 
damage. Replacement burners are available from FMI Brands Inc.

Should any part of this appliance (including the burner) become 
soiled or dirty, wipe lightly with a damp cloth. Do not use 
flammable or corrosive cleaning products on or near this unit.

Ensure that gas hose is placed in an area where it is unlikely to 
be tripped over (such as pathways or trails) or subject to other 
accidental damage.

Keep the appliance area clear and free from combustible 
materials, gasoline and other flammable vapors and liquids.

Solid fuels shall not be burned in this appliance. 

Installation must conform with local codes or, in the absence of 
local codes, with either the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 
or Propane Storage and Handling Code, B149.2, or the Standard for 
Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV 
Series, Recreational Vehicle Code, 
as applicable.

NOTE TO INSTALLER: 

Leave this guide with the consumer.

NOTE TO CONSUMER: 

Please retain this guide for future use.

 WARNING:

If the information in this manual is not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life.
Installation and service must be performed by a qualified 
installer, service agency or the gas supplier.

Содержание OUTLAND FIREBOWL FMPPC2-2

Страница 1: ...D 823 000 V0 Owner s Manual FMI BRANDS INC 309 19133 26th Avenue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 Model number FMPPC2 2 Series number 823 ...

Страница 2: ...nce 2 Extinguish any open flame 3 If odour continues keep away from the appliance and immediately call your gas supplier or fire department WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For outdoor use only ...

Страница 3: ...r stabilizer such as the stabilizer ring included must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information provided on the last page of this Manual Please ensure that all adults and children which use or are near a unit in use are aware of the hazard of high surface temperatures present on the unit during...

Страница 4: ...vided at floor level of the enclosure and shall have total free area of not less than 1 2 in2 per lb 7 1 cm2 per kg of stored fuel capacity If ventilation openings at floor level area are in the side wall there shall be at least two openings The bottom of the openings shall be 1 in 25 4 mm or less from the floor level and the upper edge no more than 5 in 127 mm above the floor level The openings s...

Страница 5: ...ontact FMI Brands Inc should you require a replacement hose Inspect burner prior to each use Burner must be replaced prior to the appliance being put into operation if there is evidence of damage Replacement burners are available from FMI Brands Inc Should any part of this appliance including the burner become soiled or dirty wipe lightly with a damp cloth Do not use flammable or corrosive cleanin...

Страница 6: ...is pictured here Never handle rocks which have not been allowed to cool from exposure to flame Never attempt to rearrange rocks while unit is ignited Note Rocks are not to exceed a maximum weight of 2 kgs or 4 4 lbs SECTION 2 IGNITION STEP 1 Ensure that unit valve dial is in the OFF position by pushing and turning clockwise until the dial stops STEP 2 Securely attach regulator large end of hose to...

Страница 7: ...lame is present during operation by visually inspecting the burner to ensure the presence of flames STEP 6 Using a lighter or match ignite lighter and hold flame slightly above the burner then open the valve on the appliance slowly by turning counter clockwise until the unit ignites STEP 7 Once the unit is burning normally set the dial to desired flame height WARNING Ensure that no parts of your b...

Страница 8: ...opane cylinder is between 7 and 11 hours depending on where the flame height is set FMI Brands Inc recommends that you ignite this unit only when safely placed on a non combustible surface as pictured above This is NOT a toy Children should be supervised at all times when using this unit without exception Do not place any objects other than supplied rocks inside the burner component of the Firebow...

Отзывы: