1-888-514-1663 |
WWW.OUTLANDFIREBOWL.COM
4
LEAK TEST:
1.
DO NOT USE OR PERMIT SOURCES OF IGNITION
IN THE AREA WHILE DOING THE LEAK TEST.
THIS INCLUDES SMOKING.
2.
Leak testing should be done once per year or whenever the
LP gas cylinder or any other gas system part is taken apart,
serviced or replaced, whichever is more frequent.
3. Ensure all gas system coupling joints are tight
and properly attached.
4. Prepare a leak testing solution of half liquid detergent
and half water.
5. Apply the solution to the LP gas delivery system at points as
shown in illustration indicated on page 3.
6.
The leak(s) must be stopped by tightening the loose joints,
if possible, or by replacing the faulty parts(s) with the part(s)
recommended by the appliance manufacturer.
THE APPLIANCE IS NOT TO BE USED UNTIL
ANY LEAK IS CORRECTED.
A gas appliance repairman or LP gas dealer should be called if
attempts to stop the leak(s) are unsuccessful and, in such case, the
LP gas supply must be shut off at the cylinder valve or the cylinder
must be removed from the appliance until the leak(s) is corrected.
Inspect hose prior to each use of the unit. The hose assembly
must be replaced prior to the appliance being put into operation
if there is evidence of excessive abrasion or wear, or if the hose
is damaged. Contact FMI Brands Inc. should you require a
replacement hose.
Inspect burner prior to each use. Burner must be replaced prior
to the appliance being put into operation if there is evidence of
damage. Replacement burners are available from FMI Brands Inc.
Should any part of this appliance (including the burner) become
soiled or dirty, wipe lightly with a damp cloth. Do not use
flammable or corrosive cleaning products on or near this unit.
Ensure that gas hose is placed in an area where it is unlikely to
be tripped over (such as pathways or trails) or subject to other
accidental damage.
Keep the appliance area clear and free from combustible
materials, gasoline and other flammable vapors and liquids.
Solid fuels shall not be burned in this appliance.
Installation must conform with local codes or, in the absence of
local codes, with either the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1
or Propane Storage and Handling Code, B149.2, or the Standard for
Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 RV
Series, Recreational Vehicle Code, as applicable.
NOTE TO INSTALLER:
Leave this guide with the consumer.
NOTE TO CONSUMER:
Please retain this guide for future use.
WARNING:
If the information in this manual is not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.