background image

UNVENTED NATURAL GAS LOG HEATER

FIREPLACE MANUFACTURERS INCORPORATED

2

105191

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

SAFETY
INFORMATION

Carbon Monoxide Poisoning:

 Early

signs of carbon monoxide poisoning re-
semble the flu, with headaches, dizziness,
or nausea. If you have these signs, the heater
may not be working properly. Get fresh air
at once! 
Have heater serviced. Some people
are more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Natural Gas:

 Natural gas is odorless. An

odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.

Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this heater.

WARNING ICON

G 001

 WARNINGS

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can
cause serious injury or death from
burns, fire, explosion, electrical
shock, and carbon monoxide
poisoning.

 DANGER: Carbon monoxide

poisoning may lead to death!

 WARNING: Any change to this

heater or its controls can be
dangerous.

2.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

3.

This heater shall not be installed in a
bedroom or bathroom unless installed
as a vented appliance (see Installing
Damper Clamp Accessory
 page 10).

4.

Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or

other flammable objects are less than
42 inches from the front, top, or sides
of the heater

• in high traffic areas
• in windy or drafty areas

5.

Before installing in a solid fuel burn-
ing fireplace, the chimney flue and fire-
box must be cleaned of soot, creosote,
ashes and loose paint by a qualified
chimney cleaner. Creosote will ignite
if highly heated.  Inspect chimney flue
for damage. If damaged, operate heater
with flue damper closed.

6.

If fireplace has glass doors, never op-
erate this heater with glass doors closed.
If you operate heater with doors closed,
heat buildup inside fireplace will cause
glass to burst. Also if fireplace open-
ing has vents at the bottom, you must
open the vents before operating heater.

7.

You must operate this heater with a fire-
place screen in place. Make sure fireplace
screen is closed before running heater.

8.

This log heater is designed to be smoke-
less. If logs ever appear to smoke, turn
off heater and call a qualified service
person. 

Note:

 During initial operation,

slight smoking could occur due to log
curing and heater burning manufactur-
ing residues.

9.

To prevent the creation of soot, follow
the instructions in Cleaning and Main-
tenance, 
page 20.

10. Do not allow fans to blow directly into

the fireplace. Avoid any drafts that al-
ter burner flame patterns. Ceiling fans
can create drafts that alter burner flame
patterns. Altered burner patterns can
cause sooting.

11. Before using furniture polish, wax, car-

pet cleaner, or similar products, turn
heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

12. Do not use a blower insert, heat ex-

changer insert or other accessory not
approved for use with this heater.

13. This heater needs fresh, outside air ven-

tilation to run properly. This heater has
an oxygen depletion sensor (ODS) pi-
lot light safety system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation,
 pages 4 through 6. If
heater keeps shutting off, see Trouble-
shooting,
 pages 17 through 19.

14. Do not run heater

• where flammable liquids or vapors

are used or stored

• under dusty conditions

15. Do not use this heater to cook food or

burn paper or other objects.

16. Never place any objects on the heater.

17. Heater base assembly becomes very hot

when running heater. Keep children and
adults away from hot surface to avoid
burns or clothing ignition.  Heater will
remain hot for a time after shutdown.
Allow surface to cool before touching.

18. Carefully supervise young children

when they are in the room with heater.

19. Do not use heater if any part has been

exposed to or under water. Immediately
call a qualified service technician to in-
spect the room heater and to replace any
part of the control system and any gas
control which has been under water.

20. Do not operate heater if any log is bro-

ken. Do not operate heater if a log is
chipped (dime-sized or larger).

21. Turn heater off and let cool before ser-

vicing. Only a qualified service person
should service and repair heater.

22. Operating heater above elevations of

4,500 feet could pilot outage.

Содержание Heat Majic FVF18N

Страница 1: ...e gas supplier s instructions If you cannot reach your gas sup plier call the fire department Installation and service must be performed by a qualified installer ser vice agency or the gas supplier WARNING Improper installation ad justment alteration service or mainte nancecancauseinjuryorpropertydam age Refer to this manual for correct installationandoperationalprocedures For assistance or additi...

Страница 2: ...his heater with glass doors closed If you operate heater with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace open ing has vents at the bottom you must open the vents before operating heater 7 You must operate this heater with a fire placescreeninplace Makesurefireplace screen is closed before running heater 8 This log heater is designed to be smoke less If l...

Страница 3: ...ater has a piezo ignitor This system requires no matches batteries or other sources to light heater UNPACKING CAUTION Do not remove the metal Data Plates from the grate assembly TheDataPlatescontain important product information 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by the burner This could damage heater Always handle base assembly by grate 2 ...

Страница 4: ...truction methods helpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as possible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All fuel burning appliances need fresh air for proper com bustion a...

Страница 5: ...bustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 71 500 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space ...

Страница 6: ...on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fr...

Страница 7: ...reeheatersaddmois ture to the air Although this is beneficial installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Com bustion and Ventilation pages 4 through 6 NOTICE Stateorlocalcodesmay onlyallowoperationofthisappli ance in a vented configuration Check your state or local codes INSTALLATION AND CLEARANCES Vent Free Operation Only ...

Страница 8: ...lace hood accessory HDABK or HDABR see Accessories page 21 18 Model Noncombustible material OK Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open NOTICE Manual control heaters maybeusedasaventedproduct If so you must always run heater with chimney flue damper open If running heate...

Страница 9: ...required Followminimumclear ances shown in Figure 7 when using hood NOTICE If your installation does notmeettheminimumclearances shown you must do one of the following operate the logs only with the flue damper open raise the mantel to an accept able height remove the mantel Continued FLOOR CLEARANCES A If installing appliance on the floor level you must maintain the minimum dis tance of 14 to com...

Страница 10: ...l burning fireplace with a working flue and constructed of non combustible material Ifyourheaterisamanuallycontrolledmodel you may use this heater as a vented product There are three reasons for operating your heater in the vented mode 1 The fireplace does not meet the clear ance to combustibles requirements for vent free operation 2 State or local codes do not permit vent free operation 3 You pre...

Страница 11: ...PORTANT Hold gas regulator with wrench when connecting flexible gas hose 2 Locate two masonry screws in hard ware package 3 Place heater base in fireplace 4 Place logs in their proper position on heater base 5 Center heater base and logs front to back and side to side in fireplace 6 Carefully remove logs without moving heater base 7 Mark screw locations through one hole on each side of the mountin...

Страница 12: ... certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur WARNING Never connect heater to private non utility gas wells This gas is commonly known as wellhead gas CAUTION Avoid damage to regulator Holdgasregulatorwith wrenchwhenconnectingittogas piping and or fittings Installsedimenttrapinsu...

Страница 13: ...sures In Excess Of 1 2 PSIG 1 Disconnect heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressurize supply piping system by ei ther using compressed air or opening main gas valve located on or near gas meter 4 Check all joints of gas su...

Страница 14: ...ailuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury INSTALLING LOGS INSTALLATION Continued CAUTION After installation andperiodicallythereafter check to ensure that no flame comes in contact with any log With the heater set to High check to see if flames contact any log If so re...

Страница 15: ...ow to vent smell Thiswillonlylastafewhours Note Home owners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there may be times you will desire the full flames of the High heat setting but will find the heat output excessive You can open the chim ney damper if you have one fully or partially to release some of the heat WARNING...

Страница 16: ... heater between PILOT and HIGH positions CAUTION Donottrytoadjust heating levels by using the manual shutoff valve The variable control valve can be set to anyheatsettingandflameheightdesired by simply turning the control knob until that setting is attained Even the lowest setting provides realistic dancing yellow flames Selectinghighersettingsproduces greater heat output This results in in crease...

Страница 17: ...nect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace ignitor 7 Replace ignitor 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILO...

Страница 18: ...atural gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burners see Cleaning and Mainte nance page 20 or replace burner orifice 1 Refer to Air for Combustion and Venti lation requirements pages 4 through 6 1 Properly locate logs see Installing Logs page 14 2 Eliminate source of drafts around heater 3 Clean out air holes at burner inlet Peri odically repeat as ne...

Страница 19: ...h air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS oper...

Страница 20: ...low the proper amount of air to mix with the gas This provides a clean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500 hours of operation or every three months Wealsorecommendthatyoukeeptheburner tube and pilot assembly clean and free of dustanddirt To...

Страница 21: ... ready model number of your heater the replacement part number REPLACEMENT PARTS SPECIFICATIONS Heat Majic 18 Heat Majic 24 30 Variable Manually Variable Manually Controlled Controlled Btu Variable 16 000 27 000 16 000 31 500 Type Gas Natural Gas Only Natural Gas Only Ignition Piezo Piezo Piezo Pressure Manifold 3 5 W C 3 5 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 Minimum 5 5 Shipping ...

Страница 22: ...ED NATURAL GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED 22 105191 ILLUSTRATED PARTS BREAKDOWN HEAT MAJIC FVF18N FVF24N FVF30N ODS Pilot 4 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 2 18 13 19 17 20 18 3 1 ...

Страница 23: ... 18 099056 18 Burner Orifice Injector 1 11 102843 01 102843 01 102843 01 Burner Clip 1 12 102963 01 102773 01 102773 01 Burner 1 13 102568 07 102568 07 102568 07 Control Valve 1 14 098508 01 098508 01 098508 01 Valve Retainer Nut 1 15 098354 01 098354 01 098354 01 Control Knob 1 16 102445 01 102445 01 102445 01 Piezo Ignitor 1 17 098249 01 098249 01 098249 01 Nut M5 2 18 099387 08 099387 08 099387...

Страница 24: ... MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transpo...

Отзывы: