background image

2

105224

UNVENTED PROPANE/LP GAS LOG HEATER

FIREPLACE MANUFACTURERS INCORPORATED

SAFETY
INFORMATION

 DANGER: Carbon monoxide

poisoning may lead to death!

Carbon Monoxide Poisoning:

 Early

signs of carbon monoxide poisoning re-
semble the flu, with headaches, dizziness,
or nausea. If you have these signs, the heater
may not be working properly. Get fresh air
at once!
 Have heater serviced. Some people
are more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Propane/LP Gas: 

Propane/LP gas is odor-

less. An odor-making agent is added to the gas.
The odor helps you detect a gas leak. How-
ever, the odor added to the gas can fade. Gas
may be present even though no odor exists.

Make certain you read and understand all
Warnings. Keep this manual for reference.
It is your guide to safe and proper operation
of this heater.

1.

This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.

2.

Do not place propane/LP supply tank(s)
inside any structure. Locate propane/
LP supply tank(s) outdoors.

3.

To prevent performance problems, the
use of a propane/LP tank of less than
100 lbs. capacity is not recommended.

WARNING ICON

G 001

 WARNINGS

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this heater. Im-
proper use of this heater can
cause serious injury or death from
burns, fire, explosion, electrical
shock, and carbon monoxide
poisoning.

 WARNING: Any change to this

heater or its controls can be
dangerous.

4.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

5.

This heater shall not be installed in a
bedroom or bathroom, unless installed
as a vented appliance (see Installing
Damper Clamp Accessory, 
page 10).

6.

Never install the heater
• in a recreational vehicle
• where curtains, furniture, clothing, or

other flammable objects are less than
42 inches from the front, top, or sides
of the heater

• in high traffic areas
• in windy or drafty areas

7.

Before installing in a solid fuel burn-
ing fireplace, the chimney flue and fire-
box must be cleaned of soot, creosote,
ashes and loose paint by a qualified
chimney cleaner. Creosote will ignite
if highly heated.  Inspect chimney flue
for damage. If damaged, operate heater
with flue damper closed.

8.

If fireplace has glass doors, never op-
erate this heater with glass doors closed.
If you operate heater with doors closed,
heat buildup inside fireplace will cause
glass to burst. Also if fireplace open-
ing has vents at the bottom, you must
open the vents before operating heater.

9.

You must operate this heater with fireplace
screens in place. Make sure fireplace
screens are closed while running heater.

10. This log heater is designed to be smoke-

less. If logs ever appear to smoke, turn off
heater and call a qualified service person.

Note:

 During initial operation, slight

smoking could occur due to log curing and
heater burning manufacturing residues.

11. To prevent the creation of soot, follow

the instructions in Cleaning and Main-
tenance, 
page 20.

12. Do not allow fans to blow directly into the

fireplace. Avoid any drafts that alter burner
flame patterns. Ceiling fans can create
drafts that alter burner flame patterns. Al-
tered burner patterns can cause sooting.

13. Before using furniture polish, wax, car-

pet cleaner, or similar products, turn

heater off. If heated, the vapors from
these products may create a white pow-
der residue within burner box or on
adjacent walls or furniture.

14. Do not use a blower insert, heat ex-

changer insert or other accessory not
approved for use with this heater.

15. This heater needs fresh, outside air ven-

tilation to run properly. This heater has
an oxygen depletion sensor (ODS) pi-
lot light safety system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation,
 pages 4 through 6. If
heater keeps shutting off, see Trouble-
shooting,
 pages  17 through 19.

16. Do not run heater

• where flammable liquids or vapors

are used or stored

• under dusty conditions

17. Do not use this heater to cook food or

burn paper or other objects.

18. Never place any objects on the heater.

19. Heater base assembly becomes very hot

when running heater. Keep children and
adults away from hot surface to avoid
burns or clothing ignition.  Heater will
remain hot for a time after shutdown.
Allow surface to cool before touching.

20. Carefully supervise young children

when they are in the room with heater.
When using the hand-held remote ac-
cessory, keep remote selector switch in
the OFF position to prevent children
from turning on burner with remote.

21. Do not use heater if any part has been

exposed to or under water. Immediately
call a qualified service technician to in-
spect the room heater and to replace any
part of the control system and any gas
control which has been under water.

22. Do not operate heater if any log is bro-

ken. Do not operate heater if a log is
chipped (dime-sized or larger).

23. Turn heater off and let cool before ser-

vicing, installing, or repairing. Make sure
the remote selector switch is in the OFF
position. Only a qualified service person
should install, service, or repair heater.

24. Make sure the remote selector switch is

in the OFF position when you are away
from home for long periods of time.

25. Operating heater above elevations of

4,500 feet could cause pilot outage.

Содержание FVFM27PR

Страница 1: ...pplier WARNING Improper installation ad justment alteration service or main tenance can cause injury or property damage Refer to this manual for cor rect installation and operational pro cedures For assistance or additional informationconsultaqualifiedinstaller service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed ...

Страница 2: ...ter with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace open ing has vents at the bottom you must open the vents before operating heater 9 Youmustoperatethisheaterwithfireplace screens in place Make sure fireplace screens are closed while running heater 10 This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qu...

Страница 3: ...slandfireboxes with multiple openings You may also in stall this log heater in a standard firebox SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS TheODS pilotisarequiredfeatureforvent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater has a piezo ignitor This system requires no matches batt...

Страница 4: ...ace as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate inputratingofallappliancesinstalledinthat space Rooms communicating directly with the space in which th...

Страница 5: ...ir from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 79 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space because t...

Страница 6: ...ir From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlledp...

Страница 7: ...will ignite if highly heated A dirty chimney flue may create and dis tribute soot within the house In spect chimney flue for damage If damaged operate heater with flue damper closed WARNING Seal any fresh air vents or ash clean out doors lo cated on floor or wall of fireplace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper CAUTION This...

Страница 8: ...2 Installfireplacehoodaccessory HDABKorHDABR see Accessories page 21 Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open NOTICE Manual control heaters maybeusedasaventedproduct If so you must always run heater with chimney flue damper open If running heater with damper open non com...

Страница 9: ...antel Top of Fireplace Opening Underside of Mantel Shelf Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inches 20 2 1 2 6 8 10 12 Distances to Underside of Mantel Hood Top of Fireplace Opening Log Sets All Models Underside of Mantel Shelf Mantel Shelf Figure 8 Minimum Fireplace Clearances I...

Страница 10: ...ter base assembly by the burner This could damage heater Only handle base assem bly by grates WARNING You must secure this heater to fireplace floor If not heater will move when you adjust controls Moving heater may cause a gas leak IMPORTANT Makesuretheheaterburner is level If heater is not level heater will not work properly CAUTION Do not remove the metal data plates attached to the heater base...

Страница 11: ...ant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occu...

Страница 12: ...d connections for leaks after installing or servicing Cor rect all leaks at once CAUTION Make sure exter nal regulator has been installed between propane LP supply and heater See guidelines under Con necting to Gas Supply page 11 CHECKING GAS CONNECTIONS Test Pressures Equal To or Less Than 1 2 PSIG 1 Close manual shutoff valve see Fig ure 15 2 Pressurize supply piping system by ei ther using comp...

Страница 13: ... of unit place top log 2 onto the pegs in the center of the bot tom log see Figure 19 3 Position log piece 3 by aligning holes on underside with remaining pegs on bottom log see Figure 20 4 Place lava rock on fireplace floor around base of heater Figure 17 Installing Bottom Log 1 Figure 18 Installing Log set Top View Logs Burner Ports Bottom Log 1 Burner Chassis CAUTION After installation andperio...

Страница 14: ...erating heater You must operate this heater with a fireplace screen in place Make sure fireplace screen is closed before running heater NOTICE During initial operation of new heater burning logs will give off a paper burning smell Open damper or window to vent smell This will only last a few hours Note Home owners generally prefer to operate their heater with the chimney damper closed This will pu...

Страница 15: ...entral heating system etc 1 Follow steps 1 through 6 under Light ing Instructions page 14 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow steps 9 through 11 column 1 OPTIONAL REMOTE OPERATION NOTICE You must light the pilot before using the hand held re mote control unit See Lighti...

Страница 16: ...shows a correct pilot flame pat tern Figure 26 shows an incorrect pilot flame pattern The incorrect pilot flame is not properly heating the thermocouple When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 26 turn heater off see To Turn Off Gas to Appliance page 15 see Troubleshooting pages 17 through 19 Pilot Burner Thermocouple INSPECTING B...

Страница 17: ...nnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace piezo ignitor 7 Replace piezo ignitor 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob ...

Страница 18: ...tion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burner see Cleaning and Mainte nance page 20 or replace burner orifice 1 Turn heater off when using furniture polish w...

Страница 19: ...n with most heaters If noise is excessive contact qualified ser vice person 1 Open window and ventilate room Stop using odor causing products while heater is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 20 1 Locate and correct all leaks s...

Страница 20: ...or Holder On Outlet Burner Tube 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot a...

Страница 21: ...page of this manual FIREPLACE HOOD Black HDABK Part 01244 Brass HDABR Part 01245 Antique Brass GA6053 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 49 wide LAVA ROCK 02016 Not Shown For all models Order when additional rock is desired 3 lb bag DAMPER CLAMP 02017 not shown Permanently opens chimney flue damper for vented operation Can be used only wi...

Страница 22: ...ROPANE LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED ILLUSTRATED PARTS BREAKDOWN FVFM27PR 5 O F F P I L O T O N H I L O O F F P I L O T O N H I L O 1 9 3 2 13 12 15 14 18 17 12 12 16 21 12 19 6 8 7 4 11 12 20 9 10 ...

Страница 23: ...e Injector 1 8 104591 01 Burner 1 9 099387 13 Pilot Tube 1 10 103781 02 Gas Control Valve 1 11 104611 01 Lower Bracket 1 12 098304 01 Screw 8 x 38 7 13 104590 01CK Painted Base Assy 1 14 098271 06 Ignitor Cable 1 15 102445 01 Piezo Ignitor 1 16 103587 02 Plate Switch 1 17 103784 02 Flame Adjustment Knob 1 18 103784 01 Off Pilot On Knob 1 19 M12461 26 Screw Hex Slt Wsr 10 32 x 38 4 20 103284 02 Wir...

Страница 24: ...rdance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to...