background image

18

105224

UNVENTED PROPANE/LP GAS LOG HEATER

FIREPLACE MANUFACTURERS INCORPORATED

OBSERVED PROBLEM

Burner does not light after ODS/pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Moisture/condensation noticed on windows

Heater produces a whistling noise when
burner is lit

White powder residue forming within burner
box or on adjacent walls or furniture

Remote does not function (FHRC and
FHRCT only)

REMEDY

1. Clean burner (see Cleaning and Main-

tenance, page 20) or replace burner orifice

2. Contact local propane/LP gas company
3. Replace burner orifice
4. Reconnect leads (see 

Wiring Diagram,

page 21)

5. Replace battery in transmitter and

receiver

1. Contact local propane/LP gas company
2. Clean burner (see Cleaning and Main-

tenance, page 20) or replace burner orifice

1. Clean burner (see Cleaning and

Maintenance, page 20) or replace burner
orifice

2. Replace damaged burner
3. Replace gas control

1. Check burner for dirt and debris. If

found, clean burner (see Cleaning and
Maintenance
, page 20)

2. Replace gas control
3. Problem will stop after a few hours of

operation

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local pro-
pane/LP gas company

3. Observe minimum installation clear-

ances (see pages 7 through 9)

4. Clean burner (see Cleaning and Mainte-

nance, page 20) or replace burner orifice

1. Turn heater off when using furniture

polish, wax, carpet cleaners, or similar
products

1. Replace 9-volt batteries in receiver and

remote control

TROUBLESHOOTING

Continued

POSSIBLE  CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or im-

properly connected

5. Burners will not come on in remote po-

sition

1. Manifold pressure is too low
2. Burner orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing processes

and logs curing

1. Not enough combustion/ventilation air

1. Turning control knob to HI position

when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. turn into
white powder residue

1. Battery is not installed. Battery power

is low

www.desatech.com

Содержание FVFM27PR

Страница 1: ...pplier WARNING Improper installation ad justment alteration service or main tenance can cause injury or property damage Refer to this manual for cor rect installation and operational pro cedures For assistance or additional informationconsultaqualifiedinstaller service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed ...

Страница 2: ...ter with doors closed heat buildup inside fireplace will cause glass to burst Also if fireplace open ing has vents at the bottom you must open the vents before operating heater 9 Youmustoperatethisheaterwithfireplace screens in place Make sure fireplace screens are closed while running heater 10 This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qu...

Страница 3: ...slandfireboxes with multiple openings You may also in stall this log heater in a standard firebox SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensor Shutoff System ODS TheODS pilotisarequiredfeatureforvent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater has a piezo ignitor This system requires no matches batt...

Страница 4: ...ace as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate inputratingofallappliancesinstalledinthat space Rooms communicating directly with the space in which th...

Страница 5: ...ir from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 79 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined space because t...

Страница 6: ...ir From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlledp...

Страница 7: ...will ignite if highly heated A dirty chimney flue may create and dis tribute soot within the house In spect chimney flue for damage If damaged operate heater with flue damper closed WARNING Seal any fresh air vents or ash clean out doors lo cated on floor or wall of fireplace If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper CAUTION This...

Страница 8: ...2 Installfireplacehoodaccessory HDABKorHDABR see Accessories page 21 Less than 8 Noncombustible material must be extended to at least 8 See Between 8 and 12 above If you cannot extend material you must operate heater with flue damper open NOTICE Manual control heaters maybeusedasaventedproduct If so you must always run heater with chimney flue damper open If running heater with damper open non com...

Страница 9: ...antel Top of Fireplace Opening Underside of Mantel Shelf Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inches 20 2 1 2 6 8 10 12 Distances to Underside of Mantel Hood Top of Fireplace Opening Log Sets All Models Underside of Mantel Shelf Mantel Shelf Figure 8 Minimum Fireplace Clearances I...

Страница 10: ...ter base assembly by the burner This could damage heater Only handle base assem bly by grates WARNING You must secure this heater to fireplace floor If not heater will move when you adjust controls Moving heater may cause a gas leak IMPORTANT Makesuretheheaterburner is level If heater is not level heater will not work properly CAUTION Do not remove the metal data plates attached to the heater base...

Страница 11: ...ant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occu...

Страница 12: ...d connections for leaks after installing or servicing Cor rect all leaks at once CAUTION Make sure exter nal regulator has been installed between propane LP supply and heater See guidelines under Con necting to Gas Supply page 11 CHECKING GAS CONNECTIONS Test Pressures Equal To or Less Than 1 2 PSIG 1 Close manual shutoff valve see Fig ure 15 2 Pressurize supply piping system by ei ther using comp...

Страница 13: ... of unit place top log 2 onto the pegs in the center of the bot tom log see Figure 19 3 Position log piece 3 by aligning holes on underside with remaining pegs on bottom log see Figure 20 4 Place lava rock on fireplace floor around base of heater Figure 17 Installing Bottom Log 1 Figure 18 Installing Log set Top View Logs Burner Ports Bottom Log 1 Burner Chassis CAUTION After installation andperio...

Страница 14: ...erating heater You must operate this heater with a fireplace screen in place Make sure fireplace screen is closed before running heater NOTICE During initial operation of new heater burning logs will give off a paper burning smell Open damper or window to vent smell This will only last a few hours Note Home owners generally prefer to operate their heater with the chimney damper closed This will pu...

Страница 15: ...entral heating system etc 1 Follow steps 1 through 6 under Light ing Instructions page 14 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Now follow steps 9 through 11 column 1 OPTIONAL REMOTE OPERATION NOTICE You must light the pilot before using the hand held re mote control unit See Lighti...

Страница 16: ...shows a correct pilot flame pat tern Figure 26 shows an incorrect pilot flame pattern The incorrect pilot flame is not properly heating the thermocouple When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 26 turn heater off see To Turn Off Gas to Appliance page 15 see Troubleshooting pages 17 through 19 Pilot Burner Thermocouple INSPECTING B...

Страница 17: ...nnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace piezo ignitor 7 Replace piezo ignitor 1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob ...

Страница 18: ...tion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burner see Cleaning and Mainte nance page 20 or replace burner orifice 1 Turn heater off when using furniture polish w...

Страница 19: ...n with most heaters If noise is excessive contact qualified ser vice person 1 Open window and ventilate room Stop using odor causing products while heater is running 2 Locate and correct all leaks see Check ing Gas Connections page 12 1 Open window and or door for ventilation 2 Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 20 1 Locate and correct all leaks s...

Страница 20: ...or Holder On Outlet Burner Tube 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot a...

Страница 21: ...page of this manual FIREPLACE HOOD Black HDABK Part 01244 Brass HDABR Part 01245 Antique Brass GA6053 For all models Helps deflect heat away from mantel or wall above fireplace Fits openings 28 to 49 wide LAVA ROCK 02016 Not Shown For all models Order when additional rock is desired 3 lb bag DAMPER CLAMP 02017 not shown Permanently opens chimney flue damper for vented operation Can be used only wi...

Страница 22: ...ROPANE LP GAS LOG HEATER FIREPLACE MANUFACTURERS INCORPORATED ILLUSTRATED PARTS BREAKDOWN FVFM27PR 5 O F F P I L O T O N H I L O O F F P I L O T O N H I L O 1 9 3 2 13 12 15 14 18 17 12 12 16 21 12 19 6 8 7 4 11 12 20 9 10 ...

Страница 23: ...e Injector 1 8 104591 01 Burner 1 9 099387 13 Pilot Tube 1 10 103781 02 Gas Control Valve 1 11 104611 01 Lower Bracket 1 12 098304 01 Screw 8 x 38 7 13 104590 01CK Painted Base Assy 1 14 098271 06 Ignitor Cable 1 15 102445 01 Piezo Ignitor 1 16 103587 02 Plate Switch 1 17 103784 02 Flame Adjustment Knob 1 18 103784 01 Off Pilot On Knob 1 19 M12461 26 Screw Hex Slt Wsr 10 32 x 38 4 20 103284 02 Wir...

Страница 24: ...rdance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to...

Отзывы: