DESA International warrants this product to be free from defects on burner system for four (4) years and logs for a lifetime from the
date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable
instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this log set
to proper operating condition and an allowance for labor when provided by a DESA International Authorized Service Center. Warranty
part(s) MUST be obtained through authorized dealers of this product and/or DESA International who will provide original factory
replacement parts. Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by a qualified
installer in accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become
damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost,
labor, transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT;
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA-
TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE
OF FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF
THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER
INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

www.desatech.com

KEEP THIS WARRANTY

WARRANTY INFORMATION

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written
warranty. We make no other warranty, expressed or implied.

901261-01
Rev. A
04/00

INTERNATIONAL

NOT A UPC

901261 01

Содержание FMLR18

Страница 1: ...onal procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuelburningmasonryo...

Страница 2: ...nd fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set...

Страница 3: ...s appliance See Acces sories page 19 A wall switch is also available for this appliance Youmustusethemillivoltvalve safety pilot kit to use the wall switch with this appliance See Accessories page 19...

Страница 4: ...helpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible Whi...

Страница 5: ...aws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can suppo...

Страница 6: ...adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rewo...

Страница 7: ...ATIONS Note This vented appliance must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical in...

Страница 8: ...items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench C...

Страница 9: ...all adapter fitting onto the burner inlet fitting using thread sealant on male threads of burner inlet fitting see Figure 9 Adjust to most conve nient position 4 Install the gas connector tube to the...

Страница 10: ...ver ControlKnob and Piezo Ignitor Propane LP Gas Conversion To convert to propane LP gas the burner inlet fitting and pilot orifice must be re placed Thepropane LPburnerinletfittingis supplied with th...

Страница 11: ...igure 17 Installing Grate Pan Material Not Shown Figure 18 Placement of Bottom Logs Changing Pilot Orifice The pilot is provided with a natural gas orifice installed For propane LP gas you must remove...

Страница 12: ...If the burner doesn t ignite within 10 seconds with the match burning turn the shutoff valve OFF and repeat steps 1 through 4 again Note OperationinstructionsforGA9100 Remote Ready Valve Pilot Kit wi...

Страница 13: ...ooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas Burner...

Страница 14: ...nd tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Replace burner orifice 4 Reco...

Страница 15: ...page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during...

Страница 16: ...16 901261 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN FVMR18 FVMR24 3 1 8 6 12 10 11 10 4 2 7 9 5...

Страница 17: ...3 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assembly 1 8 901232 01 901232 01 Gas Line 12 Aluminum 1 9 901...

Страница 18: ...d under Replacement Parts on page 19 of this manual KEY PART NUMBER FOR NO FMLR18 FMLR24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619 01 90161...

Страница 19: ...l models Carton of 6 GLOWING EMBERS GA9900 Not Shown For all models Use for firebox decoration only SILICA SAND GA9800 Not Shown For all models Use for firebox decoration only Carton of 6 LAVA ROCK GA...

Страница 20: ...ted to repairing a defective log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Отзывы: