background image

2

901261

VENTED NATURAL GAS LOGS

SAFETY
INFORMATION

Carbon Monoxide Poisoning:

 

Early signs

of carbon monoxide poisoning resemble the
flu, with headaches, dizziness, or nausea. If
you have these signs, the log set may not be
working properly. Get fresh air at once!
Have log set serviced. Some people are
more affected by carbon monoxide than
others. These include pregnant women,
people with heart or lung disease or anemia,
those under the influence of alcohol, and
those at high altitudes.

Natural Gas:

 Natural gas is odorless. An

odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.

Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this log set.

WARNING ICON

G 001

 WARNINGS

IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, oper-
ate, or service this log set. Im-
proper use of this log set can cause
serious injury or death from burns,
fire, explosion, electrical shock,
and carbon monoxide poisoning.

 DANGER: Carbon monoxide

poisoning may lead to death!

 WARNING: Any change to this

log set or its controls can be
dangerous.

1.

This appliance, as supplied, is only for
use with the type of gas indicated on
the rating plate. This appliance is con-
vertible for use with propane/LP, using
the GA9000 or GA9100 pilot kit.

2.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

3.

Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or

other flammable objects are less than
42 inches from the front, top, or sides
of the log set

• in high traffic areas
• in windy or drafty areas

4.

Before installing in a solid fuel burn-
ing fireplace, the chimney flue and fire-
box must be cleaned of soot, creosote,
ashes, and loose paint by a qualified
chimney cleaner. Creosote will ignite
if highly heated.  Inspect chimney flue
for damage.

5.

You must operate this log set with a fire-
place screen in place. Make sure fireplace
screen is closed before running log set.

6.

This log set is designed to be smoke-
less. If logs ever appear to smoke, turn
off appliance and call a qualified ser-
vice person. 

Note:

 During initial op-

eration, slight smoking could occur due
to log curing and the burning of manu-
facturing residues. You may wish to add
more ventilation by opening a window.

7.

To reduce the creation of soot, follow
the instructions in Cleaning and Main-
tenance
, page 13.

8.

Do not allow fans to blow directly into
the fireplace. Avoid any drafts that al-
ter burner flame patterns. Ceiling fans
can create drafts that alter burner flame
patterns. Altered burner patterns can
increase sooting.

9.

Do not use a blower insert, heat ex-
changer insert or other accessory not
approved for use with this log set.

10. This log set needs fresh, outside air ven-

tilation to run properly. See Air for
Combustion and Ventilation
, pages 4
through 6.

11. Do not run log set

• where flammable liquids or vapors

are used or stored

• under dusty conditions

12. Do not burn solid fuel in the fireplace

after installing the log set. Do not use
this log set to cook food or burn paper
or other objects.

13. Log set becomes very hot when in use.

Keep children and adults away from hot
surface to avoid burns or clothing igni-
tion.  Log set will remain hot for a time
after shutdown. Allow surface to cool
before touching.

14. Carefully supervise young children

when they are in the room with log set.

15. Do not use appliance if any part has been

exposed to or under water. Immediately
call a qualified service technician to in-
spect the room appliance and to replace
any part of the control system (if using
GA9000 or GA9100) and any gas con-
trol which has been under water.

16. To help prevent breakage, new logs

must be broken-in (see Curing Logs
page 12).

17. Turn log set off and let cool before ser-

vicing, installing, or repairing. Only a
qualified service person should install,
service, or repair log set.

 WARNING: Keep flue open

when operating unit.

Содержание FMLR18

Страница 1: ...onal procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installation only in a solid fuelburningmasonryo...

Страница 2: ...nd fire box must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set...

Страница 3: ...s appliance See Acces sories page 19 A wall switch is also available for this appliance Youmustusethemillivoltvalve safety pilot kit to use the wall switch with this appliance See Accessories page 19...

Страница 4: ...helpreduceheatlossinhomes Homeowners weather strip and caulk around windows and doorstokeepthecoldairoutandthewarmair in During heating months home owners want their homes as airtight as possible Whi...

Страница 5: ...aws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _____________ Btu Hr maximum the space can suppo...

Страница 6: ...adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts WARNING Rewo...

Страница 7: ...ATIONS Note This vented appliance must be in stalled only in a solid fuel burning fireplace with a working flue and constructed of non combustible material The charts in Figure 4 indicate technical in...

Страница 8: ...items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench C...

Страница 9: ...all adapter fitting onto the burner inlet fitting using thread sealant on male threads of burner inlet fitting see Figure 9 Adjust to most conve nient position 4 Install the gas connector tube to the...

Страница 10: ...ver ControlKnob and Piezo Ignitor Propane LP Gas Conversion To convert to propane LP gas the burner inlet fitting and pilot orifice must be re placed Thepropane LPburnerinletfittingis supplied with th...

Страница 11: ...igure 17 Installing Grate Pan Material Not Shown Figure 18 Placement of Bottom Logs Changing Pilot Orifice The pilot is provided with a natural gas orifice installed For propane LP gas you must remove...

Страница 12: ...If the burner doesn t ignite within 10 seconds with the match burning turn the shutoff valve OFF and repeat steps 1 through 4 again Note OperationinstructionsforGA9100 Remote Ready Valve Pilot Kit wi...

Страница 13: ...ooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with propane LP gas Burner...

Страница 14: ...nd tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Replace burner orifice 4 Reco...

Страница 15: ...page OBSERVED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during...

Страница 16: ...16 901261 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN FVMR18 FVMR24 3 1 8 6 12 10 11 10 4 2 7 9 5...

Страница 17: ...3 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assembly 1 8 901232 01 901232 01 Gas Line 12 Aluminum 1 9 901...

Страница 18: ...d under Replacement Parts on page 19 of this manual KEY PART NUMBER FOR NO FMLR18 FMLR24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619 01 90161...

Страница 19: ...l models Carton of 6 GLOWING EMBERS GA9900 Not Shown For all models Use for firebox decoration only SILICA SAND GA9800 Not Shown For all models Use for firebox decoration only Carton of 6 LAVA ROCK GA...

Страница 20: ...ted to repairing a defective log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OT...

Отзывы: