background image

www.fmiproducts.com

110398-01F

14

 CAUTION: Use only new, 

black  iron  or  steel  pipe.  Inter

-

nally-tinned copper tubing may 

be used in certain areas. Check 

your  local  codes.  Use  pipe  of 

1/2" diameter or greater to allow 

proper gas volume to heater. If 

pipe is too small, undue loss of 

volume will occur.

Installation must include an equipment shutoff 

valve, union, and plugged 1/8" NPT tap. Lo

-

cate NPT tap within reach for test gauge hook 

up. NPT tap must be upstream from heater 

(see Figure 14, page 15).

IMPORTANT:

 Install equipment shutoff valve 

in an accessible location. The equipment 

shutoff valve is for turning on or shutting off 

the gas to the appliance.
Check your building codes for any special 

requirements for locating equipment shutoff 

valve to fireplaces.
Apply pipe joint sealant lightly to male NPT 

threads. This will prevent excess sealant from 

going into pipe. Excess sealant in pipe could 

result in clogged heater valves.

  WARNING:  Use  pipe  joint 

sealant that is resistant to liquid 

petroleum (LP) gas.

We recommend that you install sediment trap 

in supply line as shown in Figure 14, page 

15.  Locate  sediment  trap  where  it  is  within 

reach for cleaning. Install in piping system 

between fuel supply and heater. Locate sedi

-

ment trap where trapped matter is not likely 

INSTALLATION

Continued

Figure 13 - External Regulator With Vent 

Pointing Down (propane/LP gas only)

Propane/LP 

Supply Tank

External 

Regulator 

with Vent 

Pointing 

Down

CONNECTING TO GAS SUPPLY

  WARNING:  A  qualified 

service  person  must  connect 

heater to gas supply. Follow all 

local codes.

 WARNING: Never connect 

propane/LP heater directly to the 

propane/LP supply. This heater 

requires  an  external  regulator 

(not supplied). Install the exter

-

nal regulator between the heater 

and propane/LP supply.

 WARNING: Never connect 

natural  gas  heater  to  private 

(non-utility)  gas  wells.  This 

gas is commonly known as 

wellhead gas.

Installation Items Needed

Before installing heater, make sure you have 

the items listed below.
•  external  regulator  (for  propane/LP  units 

only, supplied by installer)

•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection *
•  sediment trap
•  tee joint
•  pipe wrench
* A  equipment  shutoff  valve  with  1/8"  NPT 

tap is an acceptable alternative to test gauge 

connection. Purchase the optional equipment 

shutoff valve from your dealer.

For  propane/LP  units,  the  installer  must 

supply an external regulator. The external 

regulator will reduce incoming gas pressure. 

You must reduce incoming gas pressure to 

between 11" and 14" of water. If you do not re

-

duce incoming gas pressure, heater regulator 

damage could occur. Install external regulator 

with the vent pointing down as shown in Figure 

13. Pointing the vent down protects it from 

freezing rain or sleet.

Содержание FLAME-MAX FVFM27NR

Страница 1: ...r appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supp...

Страница 2: ...s fired heat er It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manual This appliance may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with the typ...

Страница 3: ...present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exchanger insert orotheraccessorynotap proved for use with this heater WARNING Donotallowfans toblowdirectlyintothef...

Страница 4: ...bstructions across openings of fireplace 9 This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smok ing could occur due to log curing and heater burning manufacturing residues 10 To prevent the creation of soot follow the instructions in Cleaning and Maintenance page 22 11 Before using fu...

Страница 5: ... by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts UNPACKING CAUTION Do not remove the data plates from the grate...

Страница 6: ...e through peninsula and island fireboxes with multiple openings You may also install this log heater in a standard firebox SAFETY PILOT This heater has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air PIEZO IGNITION SYSTEM This heater has a piezo ign...

Страница 7: ...less passageways or ventilation grills between them DETERMINING FRESH AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume...

Страница 8: ...ENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 Fol...

Страница 9: ...s appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rat ingplate Fieldconversionisnot permitted NOTICE Thisheater isintended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a centralheatingsystem youmay run system s circulating blower whileu...

Страница 10: ... 16 from Side Wall Example Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace NOTICE Manualcontrolheaters maybeusedasaventedproduct Ifso youmustalwaysrunheater with chimney flue damper open If running heater with damper open noncombustible material above fireplace opening is not needed GotoInstallingDamper Clamp Accessory for Vented Operation page 12 MINIMUM NONCOMBUSTIBLE MATE...

Страница 11: ...stible Material Minimum Noncombustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Figure 7 Minimum Mantel Clearances When Using Hood Minimum Noncombustible Material 8 Min 12 15 18 20 2 6 8 10 12 Distances to Underside of Mantel Hood GA6050 GA6052 or GA6053 Top of ...

Страница 12: ...l keep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum permanent flue open ing will be maintained at all times Area of Various Standard Round Flues Diameter Area 5 20 sq inches 6 29 sq inches 7 39 sq inches 8 51 sq inches Chimney Height Minimum Permanent Flue Opening 6 to ...

Страница 13: ...drill bit metal or masonry as applicable flathead screwdriver 1 Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas control Connect approved flexible INSTALLATION Continued gas hose to gas control fitting in heater see Figure 11 IMPORTANT Hold gas fitting with wrench when connecting flex ible gas hose 2 Locate two masonry screws in hardware package 3 Place heate...

Страница 14: ...ATION Continued Figure 13 External Regulator With Vent Pointing Down propane LP gas only Propane LP Supply Tank External Regulator with Vent Pointing Down CONNECTING TO GAS SUPPLY WARNING A qualified service person must connect heater to gas supply Follow all local codes WARNING Never connect propane LPheaterdirectlytothe propane LP supply This heater requires an external regulator not supplied In...

Страница 15: ... make sure external regula tor has been installed between propane LP supply and heater See guidelines under Connect ing to Gas Supply page 14 PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnect appliance with its appliance main gas valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will dama...

Страница 16: ... Figure 17 Checking Gas Joints for Propane LP Gas Control Valve Location Propane LP Supply Tank Equipment Shutoff Valve Figure 16 Checking Gas Joints for Natural Gas Gas Meter Equipment Shutoff Valve Control Valve Location 6 Light heater see Operation pages 17 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 19 INSTALLING LOGS WARNING Failure to pos...

Страница 17: ...st be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your ga...

Страница 18: ... Wait one minute and switch selector switch to the ON position to light burner Note AUTO is only functional when using GWMT1 or GWMS2 optional ac cessories Flame Adjustment Knob Figure 22 Control Knob and Ignitor Button Location Shown as Supplied No Control Options O F F P I L O T LO IH AUTO OFF ON O N Control Knob Ignitor Button Selector Switch OPERATION Continued LIGHTING INSTRUCTIONS WARNING If...

Страница 19: ...peration Selector Switch in Remote Position Optional Hand Held Remote Control ON OFF REMOTE O F F PILOT LO IH O N Control Knob in On Position Flame Adjustment Knob Piezo Ignitor MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 6 under Lighting Instructions page 18 2 Press control knob and light pilot with match 3 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds ...

Страница 20: ... fireplace off This feature is not available in the MANU mode 2 The receiver continuously receives sig nals from the hand held remote to control the room temperature If the hand held remote is misplaced obstructed or for any reason cannot transmit to the receiver the receiver will shut off the fireplace This will occur in 8 or more minutes depending upon location of remote transmitter and strength...

Страница 21: ...ter off see To Turn Off Gas to Ap pliance page 19 see Troubleshooting page 24 Note The pilot flame on natural gas units will have a slight curve but flame should be blue and have no yellow or orange color BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance These holes may become blocked with dust or lint Periodically inspect these holes for...

Страница 22: ...lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may needmorefrequentcleaningdue to excessive lint from carpeting bedding material pet hair etc WARNING Failure to keep the primary air opening s of theburner s cleanmayresultin sooting and property damage CLEANING BURNER INJECTOR HOLDER AND PILOT AIR IN...

Страница 23: ...nition Piezo Manifold Pressure 8 W C Inlet Gas Pressure in of water Maximum 14 W C Minimum 11 W C Shipping Weight 32 lbs For input adjustment REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 3...

Страница 24: ...ff or equipment shutoff valve closed 2 Control knob not in PILOT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP gas 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piez...

Страница 25: ...aged burner 3 Gas regulator defective 1 Not enough air 2 Gas regulator defective 3 Residues from manufacturing processes and logs curing REMEDY 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in 30 seconds 3 Fully open equipment shut off valve 4 A Contact local natural or propane LP gas company B Clean ODS pilot see Cleaning and Maintenance page 22 or replace ODS p...

Страница 26: ...lish wax carpet cleaners etc may turn into white powder residue 1 Battery is not installed Bat tery power is low 1 Metal expanding while heating or contracting while cooling REMEDY 1 Refer to Air for Combustion and Ventilation require ments page 6 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural o...

Страница 27: ...s see Checking Gas Con nections page 15 1 Open window and or door for ventilation 2 Contact local natural or propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 22 1 Locate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Con nections page 15 W...

Страница 28: ... F F P I L O T O N H I L O O F F P I L O T O N H I L O 9 3 2 13 12 15 14 18 17 12 12 16 21 12 19 6 8 7 4 11 12 20 10 9 23 22 1 3 1 1 1 5 1 4 1 2 PARTS MODELS FVFM27NR AND FVFM27PR NOTE Part numbers 22 and 23 are for natural gas model only ...

Страница 29: ...9056 16 099056 17 Burner Orifice Injector 1 8 104591 01 104591 01 Burner 1 9 100609 01 099387 13 Pilot Tube Regulator to Pilot 1 10 103781 05 103781 06 Gas Control Valve 1 11 104611 01 104611 01 Lower Bracket 1 12 098304 01 098304 01 Screw 8 x 0 38 7 13 Painted Base Assembly 1 14 098271 10 098271 10 Ignitor Cable 1 15 102445 01 102445 01 Piezo Ignitor 1 16 103587 02 103587 02 Switch Plate 1 17 103...

Страница 30: ...manually or thermostatically controlled mode You can turn the gas log heater on and off without ever leaving the comfort of your easy chair RECEIVER AND ON OFF REMOTE CONTROL KIT MRC For all Remote Ready Models Allows the gas log heater to be turned on and off by using a hand held remote control ON OFF F TEMP SET ON ROOM OFF MODE SET RECEIVER AND ON OFF TOUCH SCREEN REMOTE CONTROL KIT TSRC For all...

Страница 31: ..._______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________...

Страница 32: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded ...