10

For more information, visit www.desatech.com

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
FINISHING THE FIREPLACE: 

 
Combustible materials, such as wallboard, gypsum board, 
sheet rock, drywall, plywood, etc. may directly contact the 
sides and top front edge at nailing flanges of the fireplace face 
(see figure 4).  It is important that combustible materials do 
not overlap the face itself.  Brick, glass, tile or other non-
combustible materials may overlap the front face provided 
they do not obstruct louvered slots or any other opening.  
When overlapping with a non-combustible facing material, 
only use a non-combustible mortar or adhesive appropriate for 
the particular installation. 
 
GLASS DOORS: 
 
If optional glass doors are installed, all doors must be in either 
the fully opened or fully closed position whenever the 
fireplace is in use, otherwise, a fire hazard may be created (see 
literature included with glass doors). 
 
GRATE:  
 
The grate is designed to prove maximum solid-fuel capacity.  
Do not attempt to overfill.  Doing so may cause smoke 
spillage and create a fire hazard.  Do not overload the grate or 
obstruct the required air space beneath it.  Always keep ashes 
from building up under the grate. 
 

 
 

MANTEL CLEARANCES: 

 
Woodwork such as wood trims, mantels, and other 
combustible materials must be placed at least 9 inches above 
the opening of the fireplace (see figure 25). 
 
Combustible materials above 9 inches and projecting more 
than 1- ½” inches from the front face of the fireplace must be 
place at least 12 inches above the fireplace opening (Ref: 
NFPA std. 7-3.3.3).  
 
 
 

Mantels or any other combustible material may butt up to the 
side of the black metal face of the fireplace.  The clearances 
from the side of the fireplace to any combustible material and 
wall should fall within the limits shown in figure 26. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Example 1: The face of a mantel, bookshelf, etc. is made of 
combustible material and protrudes 2 3/4” from the wall the 
fireplace is installed.  This combustible material must be a 
minimum of 4” from the side of the fireplace opening. 
 
Example 2: The face of a mantel, bookshelf, etc. is made of 
combustible material and protrudes 11/16” from the wall the 
fireplace is installed.  This combustible material can butt up 
against the side of the fireplace (i.e. 1” from the fireplace 
opening). 
 

TECHNICAL SERVICE: 
 

You may have further questions about installation, operations, 
or troubleshooting.  If so, contact Desa International’s 
Technical Service Department at 

www.desatech.com

.  When 

contacting Desa International, have the model number of your 
fireplace ready. 
 
 

Figure 24              10 FOOT RULE 

 

Figure 25      MANTEL CLEARANCES

 WARNING: 

RISK OF FIRE.  REPLACE GRATE 

WITH MODEL 36 GR GRATE ONLY! 

FIREBOX

Minimum 14 inches from perpendicular side wall

TOP VIEW OF FIREPLACE

Figure 26      MINIMUM SIDE CLEARANCES 

Содержание ELIMINATOR 36E

Страница 1: ...DESA hood must be installed when using a vent free gas log set See accessories on pg 11 WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE DESA INTERNATIONAL...

Страница 2: ...LLING THE FIREPLACE PG 3 8 HEARTH EXTENSION PG 4 9 OUTSIDE AIR KIT PG 4 10 GAS LINE INSTALLATION PG 4 11 VENT FREE GAS LOG INSTALLATION PG 5 12 COLD CLIMATE INSTALLATIONS PG 5 13 CHIMNEY PIPE PG 6 7 1...

Страница 3: ...rtant step in ensuring safe and continuous operation of this fireplace SELECTING LOCATION To determine the safest and most efficient location for your fireplace consider the following guidelines The l...

Страница 4: ...level of the fireplace and shim with sheet metal if necessary STEP 5 Before securing fireplace to prepared framing the ember protector provided must be placed between hearth extensions not supplied a...

Страница 5: ...5 OPTIONAL OUTSIDE AIR KIT MODELS AK4E The outside air kit must be installed during the rough framing of the fireplace due to the nature of its location Outside combustion air can be accessed through...

Страница 6: ...be installed when using an unvented gas log set see accessories on page 11 VENTED GAS LOG INSTALLATION If you install a decorative gas appliance vented gas log the decorative gas appliance must compl...

Страница 7: ...wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained lineal gain after fitting overlaps must be taken into consideration see figure 12 Each double...

Страница 8: ...as required by most codes When the double wall pipe passes through a framed opening into an attic space the firestop must be place into the attic floor as in figure 16 When the pipe passes through a...

Страница 9: ...ermine the correct opening length and flashing required STEP 4 Remove the shingles around the opening measured and cut out this section STEP 5 Add the next sections of the pipe until the end penetrate...

Страница 10: ...E TERMINATION BEING USED Terminations with 16 slip pipe sections are available The RTT 8DM and RTTL 8DM are approved for flashing or chase installations The ETL 8DM and ETLO 8DM are terminations that...

Страница 11: ...inches above the opening of the fireplace see figure 25 Combustible materials above 9 inches and projecting more than 1 inches from the front face of the fireplace must be place at least 12 inches ab...

Страница 12: ...visit www desatech com Desa International 2701 Industrial Drive P O Box 90024 Bowling Green KY 42102 9004 www desatech com 800 323 5190 CONTACT YOUR LOCAL DEALER ACCESSORY PARTS CONTACT YOUR LOCAL DE...

Отзывы: