background image

 
 

 

                   

 

 

  

 

 

 

                                       

ELIMINATOR 

                 36” Wood Burning Fireplace 
 

                                                                                   Models

: 36E Non-Circulating (Smooth Face) 

                                                                                      I36E Non-Circulating (Smooth Face) Fully Insulated 

 

INSTALLATION INSTRUCTIONS 

 This Fireplace is approved for use as a Wood Burning Fireplace or for 
use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA 2-
72 Standards or for use with a vent-free gas log heater approved to 
ANS Z21.11.2 standard. A DESA hood must be installed when using a 
vent-free gas log set (See accessories on pg. 11). 

      WARNING

:  ALWAYS LEAVE GLASS DOORS 

FULLY OPENED OR FULLY CLOSED WHEN 
OPERATING THIS FIREPLACE. 

 

DESA INTERNATIONAL 
2701 INDUSTRIAL DRIVE 
P.O. BOX 90024 
BOWLING GREEN, KY 42102-9004 
www.desatech.com 

            PN 54013
              REV B 
                10/00 

SAVE THIS BOOK 

This book is valuable.  In addition to instructing you on how to install your fireplace, it also contains information that will enable you to 
obtain replacement parts or optional accessory items when needed.  Keep it with your other important papers. 

ICBO ES ER-3507 

Содержание ELIMINATOR 36E

Страница 1: ...DESA hood must be installed when using a vent free gas log set See accessories on pg 11 WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE DESA INTERNATIONAL...

Страница 2: ...LLING THE FIREPLACE PG 3 8 HEARTH EXTENSION PG 4 9 OUTSIDE AIR KIT PG 4 10 GAS LINE INSTALLATION PG 4 11 VENT FREE GAS LOG INSTALLATION PG 5 12 COLD CLIMATE INSTALLATIONS PG 5 13 CHIMNEY PIPE PG 6 7 1...

Страница 3: ...rtant step in ensuring safe and continuous operation of this fireplace SELECTING LOCATION To determine the safest and most efficient location for your fireplace consider the following guidelines The l...

Страница 4: ...level of the fireplace and shim with sheet metal if necessary STEP 5 Before securing fireplace to prepared framing the ember protector provided must be placed between hearth extensions not supplied a...

Страница 5: ...5 OPTIONAL OUTSIDE AIR KIT MODELS AK4E The outside air kit must be installed during the rough framing of the fireplace due to the nature of its location Outside combustion air can be accessed through...

Страница 6: ...be installed when using an unvented gas log set see accessories on page 11 VENTED GAS LOG INSTALLATION If you install a decorative gas appliance vented gas log the decorative gas appliance must compl...

Страница 7: ...wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained lineal gain after fitting overlaps must be taken into consideration see figure 12 Each double...

Страница 8: ...as required by most codes When the double wall pipe passes through a framed opening into an attic space the firestop must be place into the attic floor as in figure 16 When the pipe passes through a...

Страница 9: ...ermine the correct opening length and flashing required STEP 4 Remove the shingles around the opening measured and cut out this section STEP 5 Add the next sections of the pipe until the end penetrate...

Страница 10: ...E TERMINATION BEING USED Terminations with 16 slip pipe sections are available The RTT 8DM and RTTL 8DM are approved for flashing or chase installations The ETL 8DM and ETLO 8DM are terminations that...

Страница 11: ...inches above the opening of the fireplace see figure 25 Combustible materials above 9 inches and projecting more than 1 inches from the front face of the fireplace must be place at least 12 inches ab...

Страница 12: ...visit www desatech com Desa International 2701 Industrial Drive P O Box 90024 Bowling Green KY 42102 9004 www desatech com 800 323 5190 CONTACT YOUR LOCAL DEALER ACCESSORY PARTS CONTACT YOUR LOCAL DE...