8. Reverse the previous steps to rebuild the pump after worn or damaged components have
been replaced. FMC recommends that all seals or gaskets that are disturbed during a
service procedure be replaced. This includes the stuffing box face seal o-ring (54),
cylinder cover o-rings (75), and valve cover o-rings (52). Insure that all fasteners are
tightened to the values specified in the Fastener Torque Requirements section of this
manual.
78
77
76
75
46
Figure 4: Cylinder Cover Removal