Program
Program
Code Function
Code
Description
Entry
Code
Issue/Rev. 0.3 (8/97)
27
209
Start Delay After Stop
Enter:
Three digits in whole seconds
209
of delay time from when the "STOP"
is pressed until the "START" can be
pressed. (e.g., 020)
__ __ __
210
Pump Relay Time
Enter:
Two digits in seconds of
210
Delay
delay time for opening the pump
relay after "STOP".
(e.g., 09)
__ __
211
Valve Delay To Open
Enter:
Two digits in seconds of
211
delay time to open the valve
after "START" is pressed. (e.g., 07)
"00" disables option
__ __
212
Zero Flow Alarm
Enter:
"0" Zero Flow Alarm Disabled
212
"1" Zero Flow Alarm Enabled
__
Note: This code applies to RBU-08 and above firmware.
213-239
Unassigned at Present
213-239
240
Protection of Program
Enter:
"0" for Weights and Measures Mode
240
Codes 280-289
"1" for Program Mode
__
280
Clean Line Product
Enter:
"1" for Product 1
280
"2" for Product 2
"3" for Product 3
"4" for Product 4
__
Note: If a recipe of 100% of the Clean Line Product is being loaded the AccuLoad II will not shut down and restart to add the Clean Line Product.
This note applies to RBU-08 and above firmware.
281
Clean Line Volume
Enter:
Three digits in whole
281
units of product to be left
in the clean line at the end of
the batch. (e.g., 050)
__ __ __